  • Page 1 16 ZONE REPEATER PANEL installation manual Approved Document No. DFU1200502 Rev 2 www.acornfiresecurity.com...
  • Page 2: Table Of Contents

    E&OE. This product has been manufactured in conformance with the requirements of all applicable EU Council Directives. XFP INSTALLATION MANUAL • Approved Document No. DFU1200502 Rev 2 • Page 2 of 8 www.acornfiresecurity.com...
  • Page 3: Important Notes

    Anti-static handling guidelines Always observe appropriate electro-static handling precautions prior to handling the panel’s PCBs or any other static-sensitive components. XFP INSTALLATION MANUAL • Approved Document No. DFU1200502 Rev 2 • Page 3 of 8 www.acornfiresecurity.com...
  • Page 4: Basic Overview & Key Features

    The total network length for a Repeater network must not exceed 500 metres. Each Repeater offers all the functions and controls of an XFP Master panel (access levels 1, 2 and 3). Repeaters do not include an RS232 PC programming connector. System programming must be carried out at the XFP Master panel using the panel’s upload/download programming tools and a Windows...
  • Page 5: Mounting The Base To A Wall

    (see right). Always ensure that if a hole is cut out it is filled with a good quality cable gland. Any unused holes must be securely blanked off. XFP INSTALLATION MANUAL • Approved Document No. DFU1200502 Rev 2 • Page 5 of 8 www.acornfiresecurity.com...
  • Page 6: Mains Wiring

    Main Control PCB connector socket (connect other end of lead to the rear See Page 7 for connection details. of the Main Control PCB). XFP INSTALLATION MANUAL • Approved Document No. DFU1200502 Rev 2 • Page 6 of 8 www.acornfiresecurity.com...
  • Page 7: Installing The Standby Battery Supply

    Note the DIP switch (SW1) on the network communication card has no function when used with XFP Repeaters. To SK1 on the reverse of the Main Control PCB XFP INSTALLATION MANUAL • Approved Document No. DFU1200502 Rev 2 • Page 7 of 8 PLEASE REFER TO www.acornfiresecurity.com...
  • Page 8: Connecting The Repeater Wiring

    1.9 kg (without batteries) Cabling requirements: 1.5 mm two core, fire-resistant, screened Max. no. of Repeaters: Max. cable length per Repeater network: 500 m XFP INSTALLATION MANUAL • Approved Document No. DFU1200502 Rev 2 • Page 8 of 8 www.acornfiresecurity.com...