Download Print this page

Advertisement

Quick Links

®
Bendix
AD-IS
®
®
PURGE RESERVOIR
PRESSURE
PROTECTION
VALVES (4)
PURGE
RESERVOIR
UNL
GOVERNOR
UNLOADER (2)
22
SEC
21
DELIVERY TO
PRI
SECONDARY
DELIVERY TO
RESERVOIR
PRIMARY
RESERVOIR
FIGURE 1 - BENDIX
AD-IS
®
EverFlow
Assembly
®
BENDIX
RES
GOVERNOR
RESERVOIR (2)
PURGE VALVE
EXH
GOVERNOR
EXHAUST
AD-IS
AIR
®
DRYER PART
NUMBER
STAMPED HERE
EVERFLOW
ASSEMBLY, AD-IS
®
®
BENDIX
EVERFLOW
®
ELECTRONIC
MODULE
AD-IS
EVERFLOW
ASSEMBLY
®
®
®
DESICCANT
CARTRIDGE
GOVERNOR
SAFETY
VALVE
MOUNTING
BOLTS (3)
HEATER /
THERMOSTAT
1
IN
SUPPLY FROM
COMPRESSOR
AIR DRYER, AND EVERFLOW
®
EVERFLOW MODULE
GOVERNOR
BENDIX
AD-IS
AIR DRYER
®
®
PURAGUARD
MEDALLION
24
AUX1
AUXILIARY
DELIVERY PORTS
PRESSURE
PROTECTION
VALVES (4)
ELECTRONIC MODULE
®
®
MOUNTING
HOLES - 4
23
AUX2
AUXILIARY
DELIVERY PORT
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the AD-IS EverFlow and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BENDIX AD-IS EverFlow

  • Page 1 EXHAUST COMPRESSOR DELIVERY TO PRESSURE SECONDARY AD-IS ® DELIVERY TO PROTECTION RESERVOIR DRYER PART PRIMARY VALVES (4) NUMBER RESERVOIR STAMPED HERE FIGURE 1 - BENDIX AD-IS EVERFLOW ASSEMBLY, AD-IS AIR DRYER, AND EVERFLOW ELECTRONIC MODULE ® ® ® ® ®...
  • Page 2: General Safety Guidelines

    ▲ F o l l o w i n g t h e v e h i c l e m a n u f a c t u r e r ’s from the radar sensor whenever any tests USING recommended procedures, deactivate the A DYNAMOMETER are conducted on a Bendix ® electrical system in a manner that safely removes...
  • Page 3 OPERATION that is designed to prevent loss of engine “turbo” boost GENERAL (Refer to Figure 2) pressure during the purge cycle of the Bendix AD-IS ® ® dryer. For ease of maintenance, all replaceable assemblies The Bendix ®...
  • Page 4 AIR DRYER AND RESERVOIR SYSTEM CHARGE CYCLE ® ® AD-IS EVERFLOW AIR DRYER OPERATION: The AD-IS EverFlow assembly is primarily designed to dry air on systems used for bulk unload and central tire inflation. GENERAL The system operates best when a pressure protection valve...
  • Page 5 The governor unloads the compressor by allowing air From a flat system — approximately 80 psi — the Bendix pressure to fill the line leading to the compressor unloader ®...
  • Page 6 — such as brakes, emissions equipment and automated manual transmissions. Depending on vocation, Bendix recommends a 1, 2 or 3-year air dryer cartridge replacement on vehicles equipped with a Bendix ®...
  • Page 7 3. Visually check for physical damage such as chaffed or Symptom 4. broken air and electrical lines and broken or missing 4. Build up system pressure to governor cut-out and note parts. that one of the AD-IS EverFlow assembly dryers purges 4. Check the Bendix AD-IS EverFlow assembly and ®...
  • Page 8: Maintenance Kits

    Module -40°C (-40°F) AD-IS Discharge Line ® MAINTENANCE KITS K031562 Unloader See the proper Bendix Service Data Sheet or AD-IS Air Dryer K031559 ® Arctic Purge Valve Assembly Quick Reference Catalog (BW1114) for a full list of AD-IS EverFlow ®...
  • Page 9 When repairs are carried out, be sure to check that all reservoirs (including the air dryer purge reservoir) See Bendix publication BW5057 “Air Brake Handbook" for are emptied of all contaminants. additional information. If after bypassing the EverFlow assembly the system...
  • Page 10: Cleaning And Inspection

    Bendix parts without a governor. This check valve is located behind outlets. a hex head plug near the control line from the Bendix ® 5. Inspect all air line fittings for corrosion and replace as EverFlow electronic module to the air dryer.
  • Page 11 AD-IS EverFlow 4. Install the assembled check valve body/o-ring/spring assembly air dryer exhaust.
  • Page 12 24 volt DC. Log-on and Learn from the Best On-line training that's available when you are 24/7/365. Visit www.brake-school.com. SD-08-2417 © 2014 Bendix Commercial Vehicle Systems LLC, a member of the Knorr-Bremse Group • 07/14 • All Rights Reserved...