  • Page 1 Sonic Charger Plus MNR T R Compatible with Sonic Radiant miniRITE T R and Sonic CROS MNR T R Instructions for Use www.sonici.com...
  • Page 2 Introduction to this booklet This booklet guides you on how to use and maintain your new Sonic Charger Plus MNR T R. Ensure you read this booklet carefully, including the Warnings section. This will help you get the most benefit from your charger.
  • Page 3 Intended use Intended use The charger is intended to recharge the hearing aids and CROS transmitter that contain rechargeable batteries. The product is intended to be used together with the given hearing solution. Indications for There are no indications for use (diagnoses) for the charger itself.
  • Page 4: Table Of Contents

    Table of contents About Package contents Getting started Charger Temperature conditions Prepare charger Charge the hearing aids Daily use Charging your hearing aids Charging the charger Power bank function Power and charge using other sources Drying your hearing aids Caring for your charger...
  • Page 5 Warnings General warnings More info Troubleshooting Conditions of use Warranty Compliance statements...
  • Page 6: Package Contents

    The packaging box contains the following elements: Power plug (varies from country to country) Charger Sonic Charger Plus MNR T R Compatible with Sonic Radiant miniRITE T R and Sonic CROS MNR T R Instructions for Use www.sonici.com Cable This booklet...
  • Page 8: Charger

    Charger What it is and does USB cable Power plug Insert in power plug For power socket Battery indicator Displays charging status of Charging ports the power bank/power bank battery levels For hearing aids when charging About Getting started Daily use Warnings More info...
  • Page 9: Temperature Conditions

    Temperature conditions Temperature Charging condition Below +5°C No charging due to low temperature. (+41°F) +10°C to +35°C Best charging condition. The charging of hearing aids can (+50°F to +95°F) take up to 3 hours. +5°C to +10°C and Extended charging. The charging of hearing aids can take up +35°C to +38°C to 4 hours.
  • Page 10: Prepare Charger

    Prepare charger Connect to power source Step 1 Step 2 Step 3 Insert the USB plug Insert the other end of Insert the power plug into the power plug. the USB cable into the into a power socket. back of the charger. The charger turns ON automatically and begins charging the...
  • Page 11 Charger is turned ON When the charger is connected to power, the charger’s power bank charging status is shown. First use - Charge the power bank’s battery When you use your charger for the first time, it is important that you fully charge the charger’s built-in battery.
  • Page 12: Charge The Hearing Aids

    Charge the hearing aids Place hearing aids in charger Charging status Place the hearing aids in the The hearing aid LED lights turn ON charging ports as shown in the when the hearing aids are correctly picture and close the lid. Make sure placed in the charger.
  • Page 14: Charging Your Hearing Aids

    Charging your hearing aids Ensure you fully charge your hearing aids before first use and charge them every night. That ensures that you start your day with fully charged hearing aids. If your hearing aid’s battery is completely drained, the normal charging time is: 3 hours 1 hour...
  • Page 15 Note If you have not used your hearing aid in a long time and you then try to recharge it, it may take up to 30 seconds before the hearing aid begins charging. For more information, see your hearing aid’s instructions for use. IMPORTANT NOTICE Ensure that your charger is powered or that the charger’s built-in battery is charged when the hearing aid or transmitter is seated in the charging port.
  • Page 16: Charging The Charger

    Charging the charger Your Charger Plus contains a built-in lithium-ion rechargeable battery that doubles as a power bank. This lets you fully charge a pair of hearing aids a minimum of three times on a fully-charged power bank while you are on-the-go.
  • Page 17 When the charger is connected to a power source, the LEDs on your charger indicate the charging status of the power bank. The LEDs turn OFF shortly after the power bank battery is fully charged. Charging (Battery too low to recharge the hearing aids) Charging Fully charged ORANGE blink...
  • Page 18: Power Bank Function

    Power bank function When the charger is disconnected from power, the LEDs on your charger indicate the charger’s power bank battery level. You can check the remaining battery level by opening the charger’s lid. Three full charging cycles of two hearing aids Two full charging cycles of two hearing aids One full charging cycle of two hearing aids Battery too low for a full charging cycle...
  • Page 19: Power And Charge Using Other Sources

    Power and charge using other sources You can power and charge the charger’s battery from other sources than a power socket. This can be done by using the charger’s USB cable. Ensure that the power source is USB 2.0 compliant, with a minimum of 500mA output.
  • Page 20: Drying Your Hearing Aids

    Drying your hearing aids The Charger Plus uses heat from inductive charging to dry your hearing aids when you place them in the charger ports. The drying of your hearing aids is activated when you place the hearing aids in the charger ports and charging begins. IMPORTANT NOTICE Ensure you remove the USB cable when you transport the charger.
  • Page 21: Caring For Your Charger

    Caring for your charger Always ensure that the charger is dry and clean before use. Keep the charging ports clean from dust by using a dry cloth. Do not use water or cleaning fluids to clean the charging ports. Store your charger in a dry location, e.g. in the bedroom. Ensure you keep the charger in an environment with a temperature between +5°C and +38°C (+41°F and +100°F).
  • Page 22: Warnings

    General warnings For your personal safety and to ensure Choking hazards correct usage, you should familiarise Charger, hearing aids and their parts yourself fully with the following general should be kept out of reach of children and warnings before using your charger. anyone who might swallow these items or Consult your hearing care professional if otherwise cause injury to themselves.
  • Page 23 Explosives battery. If your skin has been in contact The charger is safe to use under normal with the leaked battery acids, use a wet usage conditions. The charger has not been cloth to wipe it off and ensure no acid is tested for compliance with international left on your skin.
  • Page 24 General warnings Fire hazards Transport on aircraft The power source in your charger has Consult the airline for details regarding insufficient energy to cause fire in normal transportation of your hearing aid charger usage conditions. on aircraft. Be aware of your surroundings Caution must be taken with active implants Avoid interacting with your charger when...
  • Page 25 Active Implants Use of third-party accessories The charger has been thoroughly tested Only use accessories, transducers, or and characterised for human health cables supplied by the manufacturer. Non- according to international standards for original accessories may result in reduced human exposure (Specific Absorption electromagnetic compatibility (EMC) of Ratio —...
  • Page 26: Troubleshooting

    Troubleshooting Symptom Possible causes The hearing aids do not turn ON after being The charger did not have enough time to turn the hearing aids ON removed from the before they were removed from the charger charger Two charger LEDs show The hearing aid or charger’s temperature is too cold or too warm ORANGE blinks Three charger LEDs show...
  • Page 27 Solutions Place the hearing aids in the charger ports and try again, or use the push button to turn the hearing aids ON manually Move the charger and hearing aid to a location with a temperature between +5°C and +38°C (+41°F and +100°F) Contact your hearing care professional Verify that the power plug is correctly connected...
  • Page 28 Troubleshooting Symptom Possible causes The hearing aid LED blinks GREEN when the The hearing aid has not been in use for an extended period of time hearing aid is placed in the charger The charger is not turned ON The hearing aid or charger’s temperature is either too warm or too cold The hearing aid LED remains turned OFF...
  • Page 29 Solutions Depending on how depleted the battery in the hearing aid is, the hearing aid automatically resumes normal charging mode after a timeframe of up to 10 minutes. Ensure you leave the hearing aid in the charger during this process. Verify that the charger power plug is correctly connected or the power bank has enough battery Move the charger and hearing aid to a location with a temperature between +5°C and +38°C (+41°F and +100°F)
  • Page 30: Conditions Of Use

    Conditions of use Operating conditions Temperature: +5°C to +38°C (+41°F to +100°F) Humidity: 5% to 93%, non-condensing Atmospheric pressure: 700 hPa to 1060 hPa Transportation and Temperature and humidity shall not exceed the below storage conditions limits for extended periods during transportation and storage: Temperature: -20°C to +60°C (-4°F to +140°F) Humidity: 5% to 93%, non-condensing...
  • Page 31 International warranty Your device is covered by an you have bought your device. Your international warranty issued by the hearing care professional may also have manufacturer. This international issued a warranty that goes beyond the warranty covers manufacturing clauses of this international warranty. and material defects in the device Please consult him/her for further itself, but not in accessories such as...
  • Page 32: Warranty

    Warranty Certificate Name of owner: _______________________________________________________ Hearing care professional: _______________________________________________ Hearing care professional’s address: _______________________________________ Hearing care professional’s phone: ________________________________________ Purchase date: ________________________________________________________ Warranty period: _______________ Month: ________________________________ Model: _______________________ Serial no.: ______________________________ About Getting started Daily use Warnings More info...
  • Page 33 Description of symbols and abbreviations used in this booklet Warnings Text marked with a warning symbol must be read before using the device. Manufacturer The device is produced by the manufacturer whose name and address are stated next to the symbol. Indicates the medical device manufacturer, as defined in EU Regulation 2017/745.
  • Page 34 Description of additional symbols used on labels Keep dry Indicates a medical device that needs to be protected from moisture. Caution symbol Consult instructions for use for warnings and cautions. Catalogue number Indicates the manufacturer’s catalogue number so that the medical device can be identified.
  • Page 35 Humidity limitation Indicates the range of humidity to which the medical device can be safely exposed. Firmware version used in the device.
  • Page 36: Compliance Statements

    Compliance statements USA and Canada User information This device complies with part 18 This equipment has been tested and of the FCC Rules. found to comply with the limits pursuant to part 18 of the FCC Rules. This device complies with FCC and Innovation, Science and Economic These limits are designed to provide Development Canada’s RF radiation...
  • Page 37 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other electronic equipment, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: •...
  • Page 38 This medical device complies with Declaration of Conformity is available at the Medical Device Regulation (EU) the headquarters. 2017/745. Sonic Innovations, Inc. 2501 Cottontail Lane Somerset, NJ 08873 www.sonici.com/doc SBO Hearing A/S Waste from electronic equipment must be handled according to Denmark local regulations.
  • Page 40 0000233842000001...