PowerMax AKD58-50 Instructions Manual

Automatic sewing machine servo controller

Advertisement

Quick Links

Automatic sewing machine Servo controller instructions
Preface
CAUTION:
This product is designed for specified sewing machines and must
not be used for other purposes.
If you have any problem or any comment, please feel free to
contact us.
Safety Instruction
All the instruction marked with sign
(1)
observed or executed; otherwise, personal injuries or risk to the
machine might occur.
This product should be installed and operated by persons
(2)
with appropriate training only.
(3)
Before connecting power supply cords to power sources, it's
necessary to make sure that the power voltage is in the range indicated
on the product name plate.
(4)
Make sure to move your feet away from the pedals while
power on.
Turn off the power and remove plug prior to the following
(5)
operations:
■ Connecting or disconnecting any connectors on the control box;
■ Repairing or doing any mechanical adjustment;
■ Threading needle or raising the machine arm;
■ Machine is out of work.
Make sure to fasten all the fasteners firmly in the control
(6)
boxes prior to the operation of the system.
Allow an interval of at least 30 seconds before repapering the system
(7)
after power off.
Please read this manual carefully, also with
related manual for the machinery before use the
controller. For installing and operating the
controller
properly
personnel are required.
Page 1 of 16
and
safely,
qualified
must be absolutely

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AKD58-50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PowerMax AKD58-50

  • Page 1 Automatic sewing machine Servo controller instructions Preface Please read this manual carefully, also with related manual for the machinery before use the CAUTION: controller. For installing and operating the controller properly safely, qualified personnel are required. This product is designed for specified sewing machines and must not be used for other purposes.
  • Page 2: Basic Parameters

    If the grounding connection is not secured, you CAUTION: may run a high risk of receiving a serious electric shock, and the controller may operate abnormally. 1. Basic parameters AKD58-50 Controller Type Max. Sewing Speed(r/min) 7000 Voltage Range AC 220±20% V 50/60HZ...
  • Page 3 Ensure all power cord, signal wire and grounding wire not be pressed by other matter or over-twisted ,and not be too close to CAUTION belt and belt wheel, keep 3cm-distance for safety. A 1Ф/220V power from a 3Ф/380V Power source Connection (See Fig.2-2): If the system have no Neutral point, then this servo motor is not suitable for this connection.
  • Page 4 * The drive ability of the LED jack: Which the rated current is100mA and the rated voltage is 5V, the output current is adjustable. Recommendatory LED diode parameter as follows: VF:Min. = 3.0V,Max. = 3.6V (test condition IF = 20mA); Peak Forward Current:Max.
  • Page 5 Automatic mode selection keys: The sensor is open, pressed in succession followed by optional automatic or semi-automatic mode. Suck selection keys: When sewing is selected suction mode, continuous press are optional before suction, back suction, before and after suction ,and suck the closure of four modes. Speed selection key: To set the maximum sewing speed.
  • Page 6: Work Mode Setting

    Figure4-2. If it is not a normal display and a fault alarm, please refer to Chapter 3 false alarms table, deal with the corresponding failure or contact the manufacturer. POWERMAX AKD58 Auto -- EC Fig. 4-2 System main interfaces In Fig.
  • Page 7 Example: If the current to full manual mode, the actual status at this time electric eye switch is off, the main interface shown in Figure 4-4. POWERMAX AKD58 Manual Fig. 4-4 full manual system main interface Press the key, then displays the current state of electric eye switch, shown in Figure 4-5.
  • Page 8 automatic and semi-automatic mode switching. After it is set, press the key to exit. 4.4 The maximum speed setting Press the key, then the system will run set to the current maximum speed shown in Figure 4-9. ---- MAX SPEED ---- ---- MAX SPEED ---- 3 0 0 0 4 5 0 0...
  • Page 9 Please follow the prompts the fabric placed on the bed, and completely covers front and back sensor, system according to the fabric thickness shows the sensitivity of maximum and minimum value, such as a fabric is shown below: : 0512 ~~ 0968 Front :...
  • Page 10: Advanced Features

    + key to complete the switch in English, as shown in Figure 5-1 and 5-2, press key + key to switch back to the Chinese interface. POWERMAX AKD58 POWERMAX AKD58 全自动-- --电控 Auto -- EC Fig.5-1 chinese interface Fig.5-2 english interface 5.2 Technicians parameter settings...
  • Page 11: Restore Factory Settings

    Running time, stop time in units of 0.1 seconds, the unit test time is 10 minutes. POWERMAX AKD58 AUTO TEST PARA Auto -- EC Run Time: 30 Fig.5-7 the main interface...
  • Page 12: Monitor Mode

    key again to return to the main interface. 5.5 Monitor Mode In the main interface, press key+ key to enter monitor mode, you can view the current system parameters, the specific content shown in Table4. Table4: monitor mode parameter Parameter No. Comment Counter stitches Counter trimming...
  • Page 13 Parameter Default Rang Comment byte Foot lifter setup when the needle stop in the middle position: 0 off; 1 automatic foot lifter Manaul stitch suck mode: 0 off;1 on 3000 2 0 0-4 200 Automatic sewing speed 5000 4 0 0-6 5 0 0 Maximum sewing speed Semi automatic continuous sewing: 0 /1...
  • Page 14 Parameter Default Rang Comment byte When it is running suction of delay time, long suction can be 100-5000 back stepped or manual trimming Close Automatic mode is completed, parking, needle of number 3000 0-5000 running speed 10-5000 Start sewing delay time (Retain) Stop delay pins ( rear sensor signal disappeared after count 1-99 sewing needle number,FB=00 signal begins to count )
  • Page 15 Parameter Default Rang Comment byte 1: Regardless of whether the thread trimming after completion, as long as the cloth out, are recognized as a work cycle. Again into the fabric, which began a new working cycle and run before trimming It is running manual trimming: 0/1 0 off;...
  • Page 16 Parameter Default Rang Comment byte Stop pin mode: 0/1 0:Constant speed tackle mode (in the belt transmission, 1: back pull mode (PMX) Parking is not precision) It is running time reset Translating Parameter 0:no action 1:Download parameters( the panel will parameter from panel 0/1/2 to controller ) Operation...