Summary of Contents for VS LIGHTING SOLUTIONS 186880
Page 1
LED Drivers CC ComfortLine NFC/LEDSet COMFORTLINE NFC/LEDSET S-MIDNIGHT 186880, 186881, 186882, 186883 Typical Applications Built-in in compact luminaires • Street lighting • Industrial lighting ComfortLine NFC/LEDSet S-MidNight SELECTABLE OUTPUT CURRENT VIA NFC OR LEDSET MIDNIGHT FUNCTION VERY LOW RIPPLE CURRENT: < 5% ...
Page 2
• Mains frequency: 50–60 Hz • Push-in terminals: 0.2–1.5 mm² • EN 61000-3-2 • Power factor at full load: • EN 61347-1 186880, 186881: > 0.95 • EN 61347-2-13 186882, 186883: > 0.98 • EN 61547 • Open circuit voltage (U ): 60 V (186880, •...
Page 3
LED Drivers – ComfortLine NFC/LEDSet S-MidNight Product drawings and photos K3.1 K3.1 – 186880, 186881 K72 – 186882 K74 – 186883 The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
100 Hz V (± 10%) A / µs mA (± 5%) DC (V) % (230 V) % (230 V) ECXe 1050.357 186880 220–240 25 / 150 200–1050 10–38 < 5 ECXe 1050.358 186881 220–240 25 / 180 200–1050...
Page 5
LED Drivers – ComfortLine NFC/LEDSet S-MidNight Typ. performance graphs for 186880 / Type ECXe 1050.357 Working area Efficiency Power factor Total harmonic factor (THD) Typ. performance graphs for 186881 / Type ECXe 1050.358 Working area Efficiency Power factor Total harmonic factor (THD) The values contained in this data sheet can change due to technical innovations.
Page 6
LED Drivers – ComfortLine NFC/LEDSet S-MidNight Typ. performance graphs for 186882 / Type ECXe 1050.359 Working area Efficiency Power factor Total harmonic factor (THD) Typ. performance graphs for 186883 / Type ECXe 1050.360 Working area Efficiency Power factor Total harmonic factor (THD) The values contained in this data sheet can change due to technical innovations.
Page 7
LED Drivers – ComfortLine NFC/LEDSet S-MidNight Safety functions MidNight function • Transient mains peaks protection: Automatic dimming via an integrated timer (no real-time clock). Values are in compliance with EN 61547 Five independent dimming levels and zones can be set using the (interference immunity).
Page 8
Using M4 screws in the designated holes pcs. • Tightening torque: 0.2 Nm Automatic cut-out type B B 10 A B 13 A B 16 A ECXe 1050.357 186880 ECXe 1050.358 186881 Electrical installation 186882 ECXe 1050.359 • Connection 186883 ECXe 1050.360...
Page 9
× 1000 • If no LEDSet resistor is mounted (delivery condition) output current is less than nominal I min. • If LEDSet interface is short circuit output current is limitied to I max. Resistors 186880 186881 186882 186883 Nominal Resistor...