Download Print this page

Advertisement

Available languages

Available languages

Quick Links

ES 150 N
( 1140909 110V 50Hz )
ELEVATORE
Manuale uso manutenzione e ricambi
HOIST
Operating,maintenance,spare parts manual
3231719 (10/2013)
IMER INTERNATIONAL S.p.A.
Via Salceto, 55 - 53036 POGGIBONSI (SI) -(ITALY)
Tel. 0577 97341 - Fax 0577 983304
www.imergroup.com

Advertisement

loading

Summary of Contents for Imer Group ES 150 N

  • Page 1 ES 150 N ( 1140909 110V 50Hz ) ELEVATORE Manuale uso manutenzione e ricambi HOIST Operating,maintenance,spare parts manual 3231719 (10/2013) IMER INTERNATIONAL S.p.A. Via Salceto, 55 - 53036 POGGIBONSI (SI) -(ITALY) Tel. 0577 97341 - Fax 0577 983304 www.imergroup.com...
  • Page 2 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz Fig. 1 LIVELLA WATER LEVEL FUNE ACCIAIO STEEL ROPE GANCIO HOOK TAMBURO DRUM MOTORE ELETTRICO ELECTRIC BRAKE AUTOFRENENTE MOTOR QUADRO ELETTRICO ELECTRIC PANEL RIDUTTORE GEAR BOX ROTARY SUPPORT TELAIO FRAME PULSANTIERA...
  • Page 3: Descrizione Generale

    IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz - Telaio portante girevole (rif.7), leva di bloccaggio telaio (rif. 11). Caro cliente, - Pulsantiera da 1,5 m a comando diretto a tre pulsanti (rif.8). ci complimentiamo per il suo acquisto dell’elevatore IMER, risultato di anni di esperienza: è...
  • Page 4 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz - La linea elettrica di alimentazione deve essere provvista sia di - 8) Non deve essere liberato un carico sospeso in modo da protezione contro le sovracorrenti, sia di tipo differenziale e che il dar luogo ad un rilascio istantaneo o tagliando l’imbracatura, dando...
  • Page 5 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz 7.1.2 CONTROLLI PERIODICI DELLA FUNE - Mantenere sempre effi ciente il funzionamento del fi necor- sa di salita verifi candoli all’ inizio di ogni turno di lavoro. - Verifi care visivamente lo stato della fune giornalmente...
  • Page 6 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz 12. IN CASO DI GUASTO DELLA MACCHINA CON CARICO SOSPESO - Controllare il livello dell’olio del riduttore attraverso la spia, prima di ogni messa in opera. Rabboccare in caso di mancanza...
  • Page 7 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz Dear customer, withstand the stresses generated during operation (¿ g. 2). Congratulations on purchasing an IMER hoist, a reliable and The 300 N force is perpendicular to the 4000 N force. Since the innovative product created through years of experience.
  • Page 8: Checks And Maintenance

    IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz 5. TESTING - 15) Ensure that the travel and work area is free of ob- - Warning!! Testing must be carried out by qualifi ed stacles throughout the height and take necessary precautions personnel only.
  • Page 9 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz Fig. 4.1 Fig. 4.2 7.3.1. Braking adjustment Remove cap 5 from fan cover 1. Increased braking: turn locknut 6 gradually counter-clockwise and check that the brake disengages in descent. Decreased braking: turn locknut 6 clockwise.
  • Page 10: Troubleshooting

    IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz 10. SCRAPPING THE HOIST To scrap the machine at the end of its service life, carry out the following steps: a) Drain out the oil by removing the oil plug. b) Separate the various plastic and electrical components (cables, pendant control, etc.).
  • Page 11 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz SCHEMA ELECTRICO - WIRING DIAGRAM Fig.6 CONDUTTORE DI PRO- PROTECTION WIRE TEZIONE CONDUTTORE NEUTRO NEUTRAL WIRE CONDUTTORE DI LINEA PHASE WIRE PULSANTE ARRESTO STOP BUTTON PULSANTE SALITA UPSTROKE BUTTON PULSANTE DISCESA...
  • Page 12 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz Fig.7 cod. 1199102 PUNTELLO PER INTERNI HOIST FRAME FOR INTERMEDIARY FLOORS POSIZIONE APPOGGIO SUPERIORE POSITIONING TOP TRAVE ELEVATORE BEAM HOIST TRAVE POUTRE BEAM TRÄGER VIGA LIVELLA ZONA LAVORO OPERATORE SPIRIT LEVEL...
  • Page 13 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz PUNTELLO A FINESTRA cod. 1199105 Fig. 12 Fig.11 HOIST FRAME FOR WINDOWS cod. 1199107 - MORSETTI PER PONTEGGIO - SCAFFOLD ATTACHMENT CLAMPS STRUTTURA DI SUPPORTO A CAVALLETTO IMER (PORTATA MAX 200 kg)
  • Page 14 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz Fig. 15 PUNTI DI VISIBILE APPIATTIMENTO VISIBLE FLATTENED POINTS CORROSIONE INTERNA O ESTERNA INTERNAL OR EXTERNAL CORROSION ROTTURA DI UN TREFOLO BREAKING OF ONE STRAND ROTTURA DI SINGOLI FILI BREAKING OF SINGLE WIRES...
  • Page 15 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz ES 150 N TAV. 1 2224350 ROSETTA ELASTICA SPRING WASHER Ø 8 1140909 2223570 DADO RIF. COD. ELEVATORE HOIST NOTE 2237662 MANICOTTO SLEEVE 3204404 TELAIO FRAME 2224340 ROSETTA WASHER Ø10X20 2201725 ALBERO TAMBURO...
  • Page 16 IMER INTERNATIONAL S.p.A. ES 150 N - 110V 50Hz...