Page 1
Battery Backup System ® NOTICE D’UTILISATION P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Système de secours à batterie Fax: 1-800-526-3757 E-Mail: flotec@flotecpump.com MANUAL DEL USUARIO Web Site: http://www.flotecwater.com Systema de respaldo de la batería 7 -4 7 -4 A .C .P O...
A ground fault cir- ble. Use of an automobile battery instead of a Flotec cuit interrupter (GFCI) is recommended for use on model FP12V27DCC, FP12V24DCC or other deep cycle any electrical appliance submerged in water.
Requests for service under this warranty shall be made by returning the defec- Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it tive product to the Retail outlet or to FLOTEC as soon as possible after the dis- shall be replaced, subject to the terms set forth below.
4166 0402 from the outlet and plug the pump power cord plug directly into the outlet. See Figure 2. Figure 2 - To bypass the float switch 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Page 5
18”. Some additional materials you will need are 2 1-1/4” 90° elbows and 2 1-1/4” close pipe nipples. Figure 5 - Remove the pre-assembled check valve 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Page 6
Check Valve to Prevent Recirculation into Sump Pipe 3546 1099 LIB Figure 6 - Back-up pump float switch tether length and Figure 7 – Method B installation diagram discharge pipe 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Page 7
Note: Always install the back-up sump pump as close to the bottom of the sump pit as possible. Figure 8 – Make the third cut to remove the excess discharge pipe 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Page 8
4. Reverse battery condition; output leads are connected backward on the battery. 5. Overcurrent condition; Something is being powered by the battery while it is charging. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Page 9
(See Figure 8). 4. Plug the primary pump back into a properly grounded 3-prong outlet. The system is now ready for operation. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
7,000 5,000 5,000 * These flow rates were obtained with a constant 12.7 VDC battery source. The average GPH will vary due to a reduction in output voltage from battery. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
An automobile battery may require charging after only 1-2 hours of continuous use, and the repeated charging cycles may cause early plate failure in the battery. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
† Included in Fittings Package. †† Includes 1-1/2 x 1-1/4 Reducer Bushings (2). ††† Included with Key No. 10. § Included with Key No. 13. • Not illustrated. * Purchase locally. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...