4.-OPERATION 5.- INSTALLATION Support position Assembling Hydraulic connection 6.- START UP 7.- MAINTENANCE Module MF list of parts List of parts MF module list of parts Module MFD List of parts MFD module Problems: Cause and solution SAFETY RULES To avoid personal or enviromental damages and to guarantee a proper...
- 4 M8 X 110 screws for the third and fourth module - Handbook NOTE: Anti-syphon valve is not provided, therefore in case it is needed, it must be explicitly ordered. 3.-TECHNICAL FEATURES MF 1 MF 2 PRESSURE FLOW PRESSURE...
4.-OPERATION The maximum pressure of an MF or MFD dosing pump when combined with one or more additional modules MI can be limited. It will be the result of dividing 2.300 for model MF1-MFD1 or 4.600 for model MF2-MFD2 by the total sum of the flows of the different installed modules, as long as this is not superior to the one specified for each module.
Page 7
STAND POSITION The special stainless steel stand has eight holes in its upper part for fastening the dosing pump, of which four will be used. In the one and three module pumps the four side holes are used, and in the two and four module middle holes are used.
Page 9
63124 (MI) 63332 (MID) 85308 Fix the cylinder, taking into account that the front number of flow indication is placed vertically. If regulator graduation (in red) does not coincide with that of the module, stick in its place the served graduation sticker, having in mind that the zero of the sticker (0) must coincide withthe ten of the module (10).
Page 10
SUCTION It is essential to fit in the suction of the dosing liquid the filter of 100 mesh supplied with the dosing pumpr. Couple the suction pipe to the lower connecter of the cylinder, putting the mesh filter in between. The stuff at the bottom of the tank must never be suctioned, to avoid taking up undiluted particles.
Page 11
6.- START UP AND REGULATION STAND: Check that the pump is properly installed in its stand. OIL: Take off re-filling lid and fill the pump with the provided oil dipstick. Approximate capacity: 100cm3 per module. Lubricants list: CEPSA SAE 80W 90 REPSOL EP 80W/90 SHELL SPIRLAX HD OIL 80W/90 ESSO GEAR OIL 80W/90...
(minimum once a year). Check the diaphragm every 3 months or 1000 hours. (MFD) Check the piston every 3 months or 1000 hours.(MF) Check the seals every 3 months or 1000 hours.(MF) Check the oil bellows every 3 months or 1000 hours.
Page 17
LIST OF PARTS MFD MODULE CODE DESCRIPTION 62129 OIL BELOWS 62131 8X10 DIN 913 ALLEN SCREW 62141 8.8 8X103 D.91 SCREW 62142 8X110 ALLEN SCREW 62150 MULTIFERTIC MODULE 62300 O'RING 19x3 FPM 62301 O'RING 19x3 NBR 62307 61X2 O'RING 62401 SUPPLEMENT AXIS 62450 MODULE AXIS...
Page 18
CAVITATION IN SUCTION - Increase pipe diameter - Reduce suction pipe length - Reduce speed through an inverter - Use a less viscous liquid PUMP TRICKLES DAMAGED SEALS(MF) - Change seals LIQUID THROUGH INFERIOR CYLINDER DAMAGED PISTON(MF) - Change piston...
Page 19
I.T.C. S.L. Warrants the product specified in this document for a period of 1 year from the purchase date. This warranty obligation is limited to the free replacement of the damaged parts due to any material or manufacture defect. This warranty does not include periodic maintenance and damage resulting from misuse.