Do you have a question about the DIGI and is the answer not in the manual?
Questions and answers
Summary of Contents for Cressi DIGI
Page 1
Manuale d’uso Manuale d’uso Manuale d’uso Manuale d’uso Manuale d’uso Manuale d’uso Manuale d’uso Manuale d’uso DIGI DIGI DIGI DIGI DIGI DIGI DIGI DIGI User Manual User Manual User Manual User Manual User Manual User Manual User Manual User Manual Manuel d’utilisation...
TABLE OF CONTENTS IMPORTANT RECOMMENDATIONS: ..................................22 READING INFORMATION ON THE SCREEN ................................24 INTRODUCTION AND MAIN FEATURES ..................................25 HOW TO CONNECT THE DIGI CONSOLE .................................25 LAUNCH SEQUENCE AFTER ACTIVATION ................................26 AUTOMATIC DISPLAY SWITCH-OFF ..................................27 BATTERY ..........................................28 CHANGING THE BATTERY .....................................30 CHANGING COLORED PROTECTED COVER ................................33 MAINTAINING THE DIGI CONSOLE ..................................34...
Cressi Sub S.p.A. recommends using the DIGI Diving in areas with particularly poor visibility console only after having read and understood this instruction could make it difficult or impossible to read the DIGI console. manual. Avoid diving in these conditions.
Page 4
I MPORTANT! Do not exceed the equipment operating limits. The pressure gauge is certified for use at pressure no greater than 300 bar. The maximum operating pressure of the gauge is shown on the back of the instrument. Failure to take these precautions can result in serious injury or even death.
READING INFORMATION ON THE SCREEN CURRENT TANK PRESSURE Graphic showing tank pressure Battery status indicator (see BATTERY chapter) TEMPERATURE Indication of the result of the most recent seal TEST...
If you have difficulty connecting/mounting Congratulations! the DIGI console, you must have this done for you by a Cressi Cressi Sub S.p.A. thanks you for your purchase of a DIGI console. Sub S.p.A. qualified technician or your trusted merchant, so long This is a sophisticated and complete instrument, designed in our as they are certified and authorized to work on Cressi Sub S.p.A.
WARNING! Do not dive if the DIGI console display shows any Immediately after it is activated, the DIGI console will run the launch unexpected values, and contact a Cressi support center. sequence, during which it will display, in order: Launch sequence WARNING!
AUTOMATIC DISPLAY SWITCH-OFF WARNING! When the “replace” low battery warning appears, The DIGI console turns off automatically after 2 minutes of inactivity replace it with a new one. when not under pressure. As soon as the console begins to read a pressure below the reserve IMPORTANT!
BATTERY DIGI will report the battery status using the following steps in how it displays the Battery Replace “ ” icon “ ” on with the rest of the display off: in this condition the battery cannot ensure the proper operation of the DIGI console.
Page 10
DIGI console may be subjected that can potentially decrease performance. We recommend employing all precautions provided in this instruction manual to safeguard the battery capacity.
Follow these steps to replace the battery Use a coin of appropriate thickness to unscrew the battery compartment cover on the back of the DIGI console. Gently insert a pointed object (a small flat head screwdriver) into the cavity, and carefully and delicately lever up the used battery.
Page 12
When the test concludes, the DIGI console will provide a response regarding the battery change that was just performed: PASS. The test was positive; the battery change was effective. Wait 30 seconds, then insert the CR2450 battery, taking care to position the new one the same way, with the positive pole facing outward without reclosing the cap.
Page 13
WARNING! If you should notice any humidity on the inside of the glass, immediately bring the DIGI console to an authorized Cressi center. It is strictly forbidden to disassemble the console or its components; doing so will immediately void the warranty.
CHANGING COLORED PROTECTED COVER The DIGI console is covered by a silicone shell that gives the product its special look while also protecting it from accidental blows. Users or an authorized center can replace the shell by following these steps: •...
WARNING! If you should need to disconnect the hose from the first stage/regulator unit and/or from the DIGI, first make sure The DIGI console should be rinsed thoroughly with fresh water after that there is absolutely no pressure in the hose.
• BACKLIGHTING: The DIGI console features a photoluminescent by Cressi Sub or by a Cressi Sub authorized service center, according display. If illuminated by an external light source, it remains to their sole judgment, and the product will be repaired or replaced luminescent depending on exposure, so it can be consulted within a reasonable time.
PRODUCT DISPOSAL You can find your authorized Cressi Sub center by asking your dealer or Cressi Sub S.p.A. itself by sending an e-mail to: Consider the device to be electronic waste.
Page 18
Benutzerhandbuch 用户手册 用户手册 用户手册 用户手册 Manual do usuário Manual do usuário Manual do usuário Manual do usuário Via Gelasio Adamoli, 501 - 16165 - Genova - Italia Tel. +39 010 830.79.1 - Fax +39 010 830.79.220 info@cressi.com • www.cressi.com rev_01_2021...
Need help?
Do you have a question about the DIGI and is the answer not in the manual?
Questions and answers