5. Watch until the boiler has reached operational pressure, turn OFF the main switch, unplug
the power cable and let it rest for 8 hours
6. After 8 hours, the machine being completely cold, shake the water/vinegar solution inside the
boiler by slightly moving the appliance back and fore.
Using a CH 22 key, open the drainage nut underneath the appliance and empty the boiler
completely, taking off all the limescale melt in the solution.
8. Fill the water tank with clean water and then switch ON the appliance.
Wait until the pump has filled the boiler completely and stopped. At this point, when the
appliance starts the heating process immediately switch OFF and disconnect the power cable.
(If the lack on water audible indicator goes ON, switch OFF and ON the appliance to let the pump
complete the boiler filling).
9. To assure a good washing and rinsing result, repeat the above steps 6, 7 and 8 for a second
time or till it is obvious that the drained water from the boiler cap is transparent and clean.
THE BOILER IS NOW READY TO USE IT AGAIN.
ATTENTION: for the first minutes the steam may have an acrid smell due to possible residuals of
the vinegar

7.5 Troubleshooting

ANOMALY
Water is leaking from the accessories
The plug of the steam hose is difficult to
insert in the proper socket on the appliance.
The boiler needs more time to heat up
The pressure goes down quickly while using
steam

8. WARRANTY

ImEx Serve s.r.l. guaranties this appliance for a period of 12 months from the date of purchase against
manufacturing blemish and defects in material.
32/36
09 EVO Junior – IM.EX.SERVE s.r.l. Italy
Due to wear out or damage of O-rings – Replace
the O-rings on the coupling paying attention not
to cut or to mark them and to place them
carefully.
Do not force to insert it, but put a bit of silicon
lubricant on the steam coupling in the
appliance.
Clean the boiler as explained above.
Symptom of limestone, clean the boiler as
explained above.
SOLUTION