hygolet S3500 Owner's Manual

Hygienic toilet seat

Advertisement

Quick Links

S3500 Hygienic Toilet Seat
Owner's Manual
hygolet.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S3500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for hygolet S3500

  • Page 1 S3500 Hygienic Toilet Seat Owner’s Manual hygolet.com...
  • Page 3: Table Of Contents

    Dear S3500 Owner, Thank you for purchasing the S3500 hygienic toilet seat. Your customers and colleagues will appreciate the improved comfort and cleanliness of the restroom. Please take the time to read this manual to understand the operation of the seat.
  • Page 4: S3500 And Disposables

    Accessories and Disposables 60.125 60.0xx 60.170 Hygoplast U125 S3500 Hygienic Toilet Seat PowerPack 60.900 60.905 60.184 Power transformer Conversion Kit Blade PowerPack to Transformer 60.970 60.950 60.990 Rubber grip kit Rubber adjuster kit Hygolet Key Sizes: S,M,L Sizes: S,M,L...
  • Page 5: Exploded Diagram

    Exploded Diagram 60.920 Lid for S3500 Lid for S3500 (Not to scale) (Not to scale) 60.600 Top housing ASM Top housing ASM 60.658 Holder for pressure roller 60.650 Pressure roller ASM 60.400 Motor module ASM Motor module ASM 60.515R Holder for hygoplast roll R 60.170...
  • Page 6: Installation

    Installation Check mounting bracket for Place S3500 flat on toilet first 2 rubber grips. Insert screw to align mounting screws with heads into small slits. Turn screw holes. 90° to snap in. Insert screws into holes. Loose- Center S3500 to align with toilet ly screw plastic nuts on screws bowl.
  • Page 7: Opening And Closing

    To open: Lift seat ring and open Lift top housing up. lock with Hygolet key. Tip: Maintenance of the S3500 is easier if the lid is removed. To remove lid, lift one side over the round pivot and slide off.
  • Page 8: First Use

    Close S3500 (pg. 7) Transformer Version Insert Hygolet transformer into The LCD will turn on. Close plug on left pivot of S3500. S3500 and allow S3500 to calibrate the sensor field *Note: Only Hygolet transformers and battery status. Allow 15 may be used.
  • Page 9: Changing The Hygoplast Roll

    Changing the Hygoplast Roll Open S3500 (pg. 7). Right side: Left side: Remove empty roll. Remove the dirty Hygoplast roll. Slide inner-core out and use it as take-up spool on the right Throw away. side. Insert new Hygoplast roll, *click* Place about 5 cm of Hygoplast into place.
  • Page 10: Changing The Powerpack

    Insert new PowerPack into The LCD will turn on. Close opening shown above. Push S3500 (pg. 7). The S3500 will calibrate the sensor field and down lightly. battery status. Allow 15 sec- onds for this.
  • Page 11: Changing The Blade

    Changing the Blade With right hand: 1. Lift blade Open S3500 (pg. 7). With right thumb Push back grey plastic with thumb 2. Pull towards you clip on the metal bracket of the with index finger. 3. Once loose, seat ring. With left hand lift seat pull straight out.
  • Page 12: Lcd Display Information

    LCD Display Information Overview of LCD display Hygoplast Status: Each bar represents 10% of the total Hygoplast roll. When only 1 Remote connection is not yet available. bar is left, change the Hygoplast roll (pg. 9). PowerPack Status: After 10 Hygoplast rolls, the Each bar represents 25% bat- “blade”...
  • Page 13: Additional Information

    Additional Information Calibration function: Tilt function: When the S3500 seat ring is Displayed when the S3500 is calibrating the sensor field. lifted above 30° the tilt func- tion will deactivate the sensor, preventing activation. Delay function: 60.950 Rubber adjuster kit and After activation, the S3500 60.970 Rubber grip kit are to...
  • Page 14: Cleaning

    The S3500 should be cleaned by following these steps when the Hygoplast roll is replaced: 1. Remove the lid 2. With the S3500 closed, lift the seat ring up 30° to deactivate the sensor, wipe the top and bottom of the housing and lower the seat ring again 3. Open the S3500 4.
  • Page 15: Troubleshooting

    LCD is blank Install PowerPack or transformer correctly (pg. 8 & 10) LCD is lit but S3500 won’t activate Check that Hygoplast can move freely around seat ring. If it is blocked, pull 1 use around by hand and untwist Hygoplast if necessary.
  • Page 16 Manufacturer: Hygolet (Europe) AG Hygolet Inc. Zürcherstrasse 70 349 SE 2nd Ave 8620 Wetzikon Deerfield Beach, FL 33441 Switzerland This product meets the requirements of the applicable EU directives. Hygolet and Hygoplast are registered trademarks. Version 06.2018...

Table of Contents