InterTest Shot QN Instruction Manual

InterTest Shot QN Instruction Manual

Hd camera control unit

Advertisement

Quick Links

QN HD Camera Control Unit Instruction &
Admin Manual
InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Shot QN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for InterTest Shot QN

  • Page 1 QN HD Camera Control Unit Instruction & Admin Manual InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832...
  • Page 2: Table Of Contents

    ....................17 Saving images ....................17 Using With A PC ................... 17 QNHD Serial Commands:.................. 17 Page 2 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 3 Capture Menu ..................34 Utility Menu .................... 34 Save Preset .................... 35 Load Preset .................... 35 Page 3 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 4 Lens Correction..................37 SCB300B Firmware Upload Procedure ............37 SCB300B AEQ Procedure ................38 NOTES: ..................... 39 Page 4 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 5: Contact Information

    Direct any questions about equipment operation to InterTest Customer Service and Support Group at 908-496-8008 or via email to service@intertest.com. Page 5 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 6: Cautionary Symbols And Symbol Terminology

    3. Use not in compliance with this manual’s instructions. Page 6 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 7: Warranty

    We neither assume, nor authorize any other person to assume for us, any other liabilities in connection with the sale of InterTest, Inc. equipment. This warranty does not apply to any equipment that has been subject to accident, negligence, alteration, abuse, unauthorized repair, improper storage, or other misuse.
  • Page 8: Copyrights And Rights Of Portrait

    QN HD CCU Instruction & Admin Manual Note: In the event the equipment cannot be returned to InterTest, Inc. The customer agrees to pay all travel and living expenses incurred to have an InterTest, Inc. representative evaluate, assess or affect a warranty repair in the field.
  • Page 9: Controls And Connections

    Yellow if not LED 2 Power Figure 1 CCU Front Figure 2 CCU Back Page 9 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 10: Connections

    USB video output MicroSD image storage External COM Port RS232 Communication from / to the CCU (EM69477) Page 10 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 11: General Operation

    Operation & Menu Top Level Page 11 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • •...
  • Page 12: Menu Tree

    WB Level: 0 to 255 Default: Auto 50 appears to be about neutral in fluorescent lighting. Page 12 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 13: Capture Setup

    Exposure Region Of Interest. Area analyzed to adjust Image EXP Sec: Auto, 1, ½, 1/3, ¼, 1/5, 1/6, Default: Auto Page 13 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 14: Utility Menu

    Allows previously stored settings to be restored Lens Correction For setting color correction of the lens installed System Diagnostic Page 14 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 15: Load Presets

    Allows up to 4 sets of camera settings to be stored for later recall and use. Load Presets Allows recall and use of any of 4 previously store sets of camera settings. Lens Correction Page 15 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 16: Pan Tilt Zoom Menu

    Confirm: changes settings to the factory default settings and returns to Main Menu. Return to Main: Returns to top of Menu Tree (Main Menu), without changing settings. Page 16 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • •...
  • Page 17: Microsd Card

    TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAG Page 17 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • •...
  • Page 18: Communication Specifications

    Command packets send action items to the camera Inquiry packets are used to ask for the current state of the CCU or camera. Page 18 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • •...
  • Page 19: Responses

    42 01 11 01 00 00 01 FF Middle 42 01 11 01 00 00 02 FF Center Page 19 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 20 0 for positive, 1 for negative. Direct 42 01 17 01 0v 00 qr FF qr: 00 - B4 Page 20 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 21 Pan (Horizontal offset) and Tilt (Vertical offset) Page 21 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 22 Y = +/- 300 This is (1920- 480)/2 qr st: 00 00 - 01 2C v: 1 = negative 0 = potitive Page 22 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 23: Inquiries

    Gamma 42 09 06 00 00 00 00 FF 42 09 06 00 00 00 0q FF q = 0-2 Page 23 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 24 0 = Positive, 1 = Negative qr st: 720: 00 00 to 00 B4 480: 00 00 to 01 2C Page 24 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 25: Shutter Table

    1/500 01 F4 1/1000 03 E8 1/5000 13 88 1/10000 27 10 1/20000 4E 20 Page 25 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 26: Specifications

    USB 2 640x480/120p LED driver output constant current P/S Up to 1A 10 step control Page 26 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 27: Controller & Camera Mechanical Specifications

    QN HD CCU Instruction & Admin Manual Controller & Camera Mechanical Specifications Page 27 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 28: Control Menu Values & Defaults

    QN HD CCU Instruction & Admin Manual Control Menu Values & Defaults Page 28 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 29: Care & Maintenance

    Overall System • Do not expose to moisture or direct sunlight. • Do not operate near intense electromagnetic fields. Page 29 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 30: Trouble Shooting

    RMA number Return Evaluation Procedure Once a return is received by InterTest, Inc. it will be evaluated. The fee for any repair evaluation not sent in under warranty is $55 (USD credited against cost of repair). This cost is in addition to any other charges required.
  • Page 31 InterTest, Inc. 303 State Route 94 Columbia, NJ 07832 1-800-535-3626 +1 908 496 8008 http://www.intertest.com Page 31 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 32: Parts And Accessories

    15.0mm Lens for QNHD Cam (10 Deg) EM15138 iShot® W/P Housing FOR QNHD EM69477 DB9F - DC3.5M Serial Cable Page 32 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 33: Admin Section

    Return to Main menu Bold-Italics means item is a submenu Control ID provided for commands that go to the ISP Page 33 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 34: More Image Quality

    Return to Main Bold-Italics means item is a submenu Control ID provided for commands that go to the ISP Page 34 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 35: Save Preset

    1 in the bit indicates pass. 1110 So for example 0xF7 indicates that everything passed except the image sensor. 1111 Page 35 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 36: Ptz Menu

    Select to exit Bold-Italics means item is a submenu Control ID provided for commands that go to the ISP Page 36 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com...
  • Page 37: Lens Correction

    8. Once you have programmed both Flash chips set DIP8 to the ON position to enter RUN mode next time you power cycle the board. Page 37 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • •...
  • Page 38: Scb300B Aeq Procedure

    5. You can turn off AEQ mode by flipping DIP6 to the Off position. The main menu will return. Page 38 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • •...
  • Page 39: Notes

    QN HD CCU Instruction & Admin Manual NOTES: Page 39 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...
  • Page 40 QN HD CCU Instruction & Admin Manual NOTES cont... Page 40 of 32 InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832 +1 (908) 496-8008 • • service@intertest.com www.intertest.com Released 7-16-20 Admin Version...

Table of Contents