Summary of Contents for NHT CLINOXX-NHT-10
Page 1
USER MANUAL High Flow Oxygen Concentrator 10LPM MODEL: CLINOXX-NHT-10 A Nanotech Product The Science of Hope Manufactured in India by: NANOFOLD HEALTHCARE TECHNOLOGIES Specialists In Medical Nanotechnology Research. Marketed by Nanofold India. Corporate Office: #3, Bellary Road, RMV Extension, Sadashivanagar, Bangalore-560080, Karnataka, India.
• Special Notes ..................4 • Safety Notice....................4 Chapter 1: Introduction ................8 • Intended Use ....................8 • About CLINOXX-NHT-10................8 • Parts of Oxygen Concentrator ..............8 • Accessories Equipment and Spare Parts ..........8 Chapter 2: Conditions of Use ..............9 • Operating Environment................9 •...
Symbol Key Mark Definition Power On Power Off Follow Instruction for Use. No Smoking Caution, Consult accompanying documents. Class II (Double Insulated) Type BF Applied Part CE Certification Mark AC Power Stacking Limit by Number This Way Up Fragile, Handle with Care Keep Dry Temperature Limit No Open Flames...
If you need assistance with this manual, please contact your local DME or home health provider The CLINOXX-NHT-10 is a prescription device. Use only the liter setting prescribed for you. It is always recommended for critically ill patients to have a backup oxygen source in case of malfunction.
Page 5
“0”. The CLINOXX-NHT-10 will make an exhaust sound while in operation. The CLINOXX-NHT-10 will vent hot air from the bottom of the unit; please do not block the vent. Blocking the vent increases risk of fire.
Page 6
• Do not touch the oxygen concentrator while wet. Do not use or store this oxygen concentrator near liquids or other electrically conductive materials. • Do not touch the CLINOXX-NHT-10 if it should fall into water or other conductive liquid. If this should occur, unplug the power cord immediately.
Page 7
THIS PAGE IS INTENDED TO SIGN BY THE DISTRIBUOTR/DEALER/RETAILER SERIAL NUMBER: NAME OF THE BUYER: TEL: E MAIL: DATE OF DELIVERY: NAME OF THE DEALER/RETAILER: TEL: E MAIL: AUTHORISED SIGNATORY & SEAL Before delivery of the equipment to the customer a copy of this page to be sent to customerservice@nhtech.in...
NOT change the flow settings unless your health care professional tells you to do so. Please read and understand this entire manual before using the device. Intended Use The CLINOXX-NHT-10 Oxygen Concentrator is intended to provide supplemental oxygen to persons requiring oxygen therapy. The device is not intended to be life supporting or life sustaining. About CLINOXX-NHT-10...
• Operating Relative Humidity: 20%RH - 65%RH • Operating Pressure atmosphere: NTP/STP • The operating environment should be dry and well ventilated. The CLINOXX-NHT-10 should never be run in environments that are dusty. Avoid electromagnetic interference when possible. Storage and Transportation Environment •...
Parameter Configuration Model CLINOXX-NHT-10 160W Rated power (W) Energy consumption 1.4kWh/m3 of O2 under NTP Voltage (v) 220V-240V ± 5V 50Hz ± 1Hz Flow rate (L/min) 0.5~10 Concentration (Rated flow) 93%±5% Sound pressure level dB (A) ≤45 Sound power level dB (A) ≤55...
III). Install the humidifier with water in the hook and loop fastener on the top of the CLINOXX-NHT-10 according to the diagram. IX). Secure the humidifier using the humidifier band. X). Connect the PVC hose to the oxygen outlet and humidifier inlet according to the diagram.
Page 12
6. Adjust the oxygen output flow to prescribed liters per minute by centering flow meterball on the proper number. Note: • The flow meter adjustment knob increases the flow rate counterclockwise and decreases the flow rate clockwise. 7. Always turn off the CLINOXX-NHT-10 when not using.
Chapter 3: Cleaning & Maintenance. Warning: It is important to unplug the device before you perform any cleaning. Excessive moisture may impair the operation of the CLINOXX-NHT-10 1. Outer exhaust fan area to be cleaned weekly. If environmental conditions are less than optimal, clean more frequently.
Page 14
1. Wash your cannula daily. Wash with mild soap and water and allow to air dry. 2. Your cannula should be replaced once a month. 3. To clean the body of the CLINOXX-NHT-10, wipe with a damp towel, mild soap may be used. Do not submerge the CLINOXX-NHT-10.
All of the above alarms are technical alarms, within 3 minutes after power on, oxygen concentration less than 82% will not alarm. 2. When troubleshooting alarms, identify failure type from LCD and contact NHT immediately. 3. Alarm system recommended test interval: 18 months.
Chapter 5: Troubleshooting. Troubleshooting Guide Problem Cause Troubleshooting Power on, the Start capacity of Call service provider or dealer. equipment is not Electrolytic cell is working. broken or piston pump is not working. Power on, the Power cord not * Check the power cord for damage equipment is not plugged securely or * Check that plug is secure...
CLINOXX-NHT-10 series oxygen generators. The CLINOXX-NHT-10 Series Oxygen Concentrators should not be used in close proximity or stacked with other equipment. If they must be used close to or stacked, they should be...
Page 18
Solutions to common problems with electromagnetic compatibility: • Operate in strict accordance with the instructions of the CLINOXX-NHT-10 series oxygen concentrator instruction manual to ensure that the device is not subject to electromagnetic interference. • Keep other devices away from this device to reduce the effects of electromagnetic interference.
Page 19
GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY: This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment. IMMUNITY IEC 60601 ELECTROMAGNETIC COMPLIANCE LEVEL TEST TEST LEVEL ENVIRONMENT G UIDANCE...
Page 20
IMMUNITY IEC 60601 COMPLIANCE LEVEL ELECTROMAGNETIC TEST TEST LEVEL ENVIRONMENT G UIDANCE Power 30 A/m 30 A/m Power frequency magnetic frequency fields should be at levels (50Hz) characteristic of a typical Magnetic field location in a typical hospital IEC61000-4-8 or home environment. Note: UT is the a.c.
Page 21
SEPARATION DISTANCE ACCORDING TO FREQUENCY OF TRANSMITTER (m) RATED MAXIMUM POWER OUTPUT OF TRANSMITTER (W) 150kHz~80MHz 80MHz-800MHz 800MHz-2.5GHz d=1.2 P d=1.2 P d=2.3 P 0.01 0.12 0.12 0.23 0.38 0.38 0.73 For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter...
Warranty Information NHT warrants that the system shall be free from defects of workmanship and materials and will perform in accordance with the product specifications for a period of TWO (2) years from the date of sale by NHT to the dealer.
Page 23
This is to cer�fy that the NANOFOLD INDIA 3, BELLARY ROAD, OPP. WHITE PETALAS PALACE RMV EXTENSION, SADASHIVNAGAR BANGLORE - 560080, INDIA has been independently assessed and is compliant with the requirements of: ISO 13485:2016 For the following scope of ac�vi�es: Certificates.
Page 24
A Nanotech Product The Science of Hope Proudly manufactured in INDIA under the scientific technological collaboration with OxyNeuron India PVT LTD - Indian Institute of Technology - Nanofold Inc USA by Nanofold Healthcare Technologies...