1. Safety precautions 1. Safety precautions This instruction manual contains warnings and safety rules which must be observed by the user to ensure safe operation of the instrument and retain it in safe condition. Therefore, read through these operating instructions before using the instrument.
readings. Wait a while to let the temperature of the instrument stabilize, and then measure. Remove the battery from the instrument, if the instrument is not in use for a long period or is put in storage. 1-4. Environmental precautions ...
2. Features 2. Features This is a contactless handheld infrared thermometer. 2. Features Temperature measurement with a K-type thermocouple is also possible. This is a contactless handheld infrared thermometer. 2. Features Alarm function Temperature measurement with a K-type thermocouple is also possible. This is a contactless handheld infrared thermometer.
Page 6
Auto power off If no key is pressed for 6 seconds, the power is shut off automatically. LCD display LCD with backlight (blinks in red when alarm function is activated) Collimation Laser beam (630 to 670nm 1mW or less) specifies the center. Display Max/ Min/ Average value display Simultaneous display: Measured value and either of max, min,...
4. Name of each part 4. Name of each part 4-1. Body 4. Name of each part 4-1. Body LASER RADIATION LASER RADIATION DO NOT STARE INTO BEAM DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT CLASS 2 LASER PRODUCT Display part Display part Laser aperture...
4-2. Display part (Buttons) ① Battery mark ..... Appears to indicate low battery. ② Laser mark ....... Appears when powering on the instrument. Buzzer mark ..... Appears when alarm function (P. 8) is enabled. ③ Thermocouple TC .... Lights up while measuring with K-type thermocouple. Emissivity [EMS] .....
5. Getting started 5. Getting started 5-1. Measurement mode and parameter setting mode Pull the trigger on the instrument to take a measurement. Press the F button (Function button) to use other functions. The main display shows measured values and the sub display shows values obtained with each function.
5-2. Other functions K-type thermocouple measurement Plug a K-type thermocouple into the connector for thermocouple, and press the function button to select TC function. Measured values using a thermocouple are displayed on the sub display. Alarm function Red backlight blinks when a measured value exceeds or falls behind the values which are set on HAL and LAL functions.
6. Battery replacement 6. Battery replacement When the battery is low, battery mark appears on the display. Replace the battery with new one. When nothing is displayed on the display if attempted, it may also be battery exhaustion. Replace the battery with new one. Open the battery cover as below figure shows, and insert a new battery with correct polarity, and then close the cover.
7. Setting emissivity (reference) 7. Setting emissivity (reference) Quantity of infrared emitted radiation from objects depends on the objects’ material, surface conditions, measuring temperatures and so on. The table below shows emissivity of some objects. Please note that these values are just for reference.