    CONTENTS INSTRUCTIONS MANUAL ..........4 USE AND CHARACTERISTICS ........5 PREPARATION BEFORE USE ........6 OPERATION INSTRUCTIONS ........9 GAS CIRCUIT SCHEMATIC DIAGRAM ....11 ELECTRIC SCHEMATIC DIAGRAM ......13 BREAKDOWN ANALYSIS ...........20 TECHNOLOGY SPECIFICATIONS ......22...
  • Page 3: Instructions Manual

    INSTRUCTION MANUAL The instructions manual are meant for all series of vacuum packing machines. Please refer to page related for individual series model. Intelligent Series & Standard Series Intelligent Series 1 : Air exhaustion to vacuum 0 ~ 99S Nitrogen filling 0 ~ 9.9S Heating 0 ~ 9.9S Cooling 0 ~ 9.9S Gas release Electric opening of cover...
  • Page 4: Use And Characteristics

    Use and Characteristics Use : Our company manufactured whole range of vacuum packing machinery. We have our own R&D team to ensure our products are capable of: Easy operation, Easy maintenance, User friendly and also to cope with wide range application. Especially suitable for soft packing material such as complex film, aluminum-foil complex film etc.
  • Page 5: Preparation Before Use

    Preparation before Use Installation 1. Before operation, please read through the Instruction Manual about each operation rules and the safety precaution 2. You must fill the vacuum pump with HFV-32 high-speed vacuum pump oil or 32N lubricant before use (When the machine is placed at a horizontal position, the oil level should keep at 3/4 of oil window.) When running, the oil level should not be lower than 1/2 height of oil window.
  • Page 6 Setting Please set every parameter first before starting machine for operation. For different machine model, please refer to this chapter. Setting of common model : 1. Connect to the power supply, turn on power switch, the indicator lamp lights. Set the time relay to adjust the vacuum and sealing timing.
  • Page 7 7. Press the “temperature selection” set key to enter into temperature set state. Press the set key once, indicate one corresponding temperature value, and the lamp shows orange color; there are three selections such as “high temperature”, “middle temperature” and “low temperature”.
  • Page 8: Operation Instructions

    Operation Instructions 1. Turn on the power supply and select a suitable vacuum packing bag for the product. 2. Set the processing parameter and select the sealing temperature. For the details, please refer to Pages 4~6. 3. Place the vacuum bag at the chamber with the opening end on top of the sealing bar. Clamp it with the hook provided.
  • Page 9 Note : 1. Silicone rubber strip come with one side nerving and the other for letter and number inserting. It will have embossed effect on sealing surface. 2. Please do not run the machine without any vacuum bag attach Otherwise, the heating element will have higher wear and tear.
  • Page 10: Gas Circuit Schematic Diagram

    Vacuum Chart diagram I: Vacuum room Gas bag Vacuum meter Vacuum pump Note: This diagram corresponds to all intelligent series model and standard model of vacuum pumps with check valve, and this model of machine do not have the function of gas flush system.
  • Page 11 Vacuum Chart diagram I I I: Note: This diagram is limited for the intelligent series model with the function of gas flush system. This model of machine adopts the vacuum pump with check valve. Vacuum circuit schematic diagram IV: Vacuum room Gas bag Air relief Isolating solenoid...
  • Page 12: Electric Schematic Diagram

    Electrical diagram I: Note: This is intelligent series model with single sealing and without the function of gas flush system. YVI Isolating solenoid valve YV2 Return-air solenoid valve M Vacuum R Heating element separately indicate High-temperature, Middle-temperature and Low temperature 031010 Intelligent control plate AC contactor...
  • Page 13 Electrical diagram I I: Note: This is intelligent series model with single sealing and the function of gas flush system. YVI Isolating solenoid valve YV2 Charging solenoid valve YV3 Return-air solenoid valve M Vacuum pump R Heating belt AC contactor separately indicate High-temperature,...
  • Page 14 Electrical schematic diagram I I I: Note: Some intelligent series model adopt electric cover opening, and aimed at the principle of electric cover opening circuit of partial models, combining electric schematic diagrams I and II, this diagram constitutes electric cover opening machine with or without gas charging model.
  • Page 15 Electrical diagram V: Note: This diagram is only meant for all standard models. In addition, for the standard model with double-sealing, you should only connect a heating element in parallel. YV2 Isolating solenoid valve YV1 Charging solenoid valve M Vacuum pump R Heating element KM AC contactor...
  • Page 16 Electrical diagram VI: Note: This model of machine is designed for intelligent series temperature selection switch, and the temperature selection is divided into two selections. YV1 Isolating solenoid valve YV2 Return-air solenoid valve KM1 AC contactor of vacuum pump KM2 AC contactor of heating...
  • Page 17 Electrical diagram VII: Note: This model is an integral machine with vacuum packing and gas flush system, and the whole processing course adopts microcomputer control. YV1 Isolating solenoid valve YV2 Return-air solenoid valve YV3 Solenoid valve of charging nitrogen FU 4A fuse SQ DZ47-60 C16 Control transformer 220V/12V/5W Heating transformer 250W.
  • Page 18 Electrical diagram VIII: Note: This model is only suitable for double-room vacuum packing machine, and the temperature adjustment of this kind of machine is divided into four selections. YV1 Isolating solenoid valve YV2 Return-air solenoid valve SQ DZ47-60 C16...
  • Page 19: Breakdown Analysis

    Breakdown analysis I. Vacuum pump and vacuum system 1. Vacuum pump does not act, the possible reasons are as follows: Limit switch is not pressed on - close the machine cover and adjust the limit switch. - adjust the pull-rod for electric cover opening machine. Time relay of vacuum pump is damaged.
  • Page 20 I I. Breakdown of heating sealing. 1. Incapable sealing, the possible reasons are as follows: The heating sealing selector switch is not selected and the heating power is not turned on. The heating element is damaged and the power connecting position of heating element is cut off. The heating time is set at “0”.
  • Page 21: Technology Specifications

    Technology Specifications Model CVP-260/PD CVP-350MS CVP-450/A Machine 480 x 330 x 320 560 x 425 x 460 560 x 520 x 460 Dimensions(mm) Chamber 450 x 370 x 460 x 4450 x 385 x 280 x 90(50) Dimensions(mm) 220(170) (170) 220 Sealer 260 x 8 350 x 8...