Intelligent Charging LSU80A Operator's Manual

Load support unit

Advertisement

Quick Links

LSU80A : Load Support Unit
Operators Manual
LSU80A
LOAD SUPPORT UNIT
OPERATORS MANUAL
Copyright Material of Intelligent Charging Limited © 2018
Doc: DWG1061-11-R2 LSU80A Operators manual.odt
Page 1 of 17
Printed On : 17/07/19

Advertisement

Table of Contents
loading

Summary of Contents for Intelligent Charging LSU80A

  • Page 1 LSU80A : Load Support Unit Operators Manual LSU80A LOAD SUPPORT UNIT OPERATORS MANUAL Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 1 of 17 Printed On : 17/07/19...
  • Page 2: Table Of Contents

    5.1.2 Current validation......................12 5.2 ADJUSTMENT PROCEDURE....................13 5.2.1 Voltage adjustment....................13 5.2.2 Current adjustment....................13 6 SPECIFICATIONS........................15 7 PRODUCT DISPOSAL INSTRUCTIONS..................16 8 PRODUCT WARRANTY......................17 Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 2 of 17 Printed On : 17/07/19...
  • Page 3: Manual Revision History

    Operators Manual 1 MANUAL REVISION HISTORY Date Description 14-07-2014 First write. 21-07-2015 Rewritten with correct drawings and formatting changes Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 3 of 17 Printed On : 17/07/19...
  • Page 4: Description

    Operators Manual 2 DESCRIPTION The LSU80A is a general purpose load support unit designed to act as a permanent power supply to maintain backup battery systems whilst alternative sources of power are either impractical or unavailable, such as running diesel engines during maintenance programs or removal of main power systems during maintenance.
  • Page 5: Installation

    3 INSTALLATION POSITIONING THE EQUIPMENT The LSU80A should be mounted on a level surface such as a workbench, sturdy shelf or a trolley. The unit should be sited so that at least 10cm of airspace is available all round the left and top of the unit and at least 20cm on the right hand side to allow free movement of air required for cooling.
  • Page 6: Controls And Indicators

    0.1V steps. When the unit is running and providing output power it will show the number of amps being provided in 1A steps. Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 6 of 17...
  • Page 7: Rear Panel

    Rackheath Ind. Est. Norwich, Norfolk, NR13 6PS, ENGLAND. TEL: +44-1603-722770 FAX: +44-1603-722771 MAIL: sales@intelligent-charging.com MAINS 115V/240V 50Hz/60Hz 16A Maximum Power cord inlet. Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 7 of 17 Printed On : 17/07/19...
  • Page 8: Operation

    4 OPERATION Before connecting to the load for the first time the LSU80A has to be set to the nominal voltage of the load system it is going to supply. The following steps must be followed prior to connecting to the load.
  • Page 9 Once the fans have stopped it is safe to remove power from the unit by moving the switch to the up off position. Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 9 of 17...
  • Page 10: Calibration

    LSU80A : Load Support Unit Operators Manual 5 CALIBRATION The LSU80A has two displays which show Voltage and Current. These are electronic displays which will require regular checking for their accuracy. Intelligent Charging recommends that the calibration check procedure is followed annually.
  • Page 11: Checking Procedure

    Current validation With a load which will give a steady 50A connected to the LU80A switch on and press the START push button. Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 11 of 17...
  • Page 12: Adjustment Procedure

    5.2.1 Voltage adjustment With no load connected to the LSU80A switch on and press the START push button. To get the unit into calibration adjustment mode press the START push button and the OUTPUT TRIM  push button both at the same time.
  • Page 13 Once complete press the START push button once and verify that it stops flashing and remains steady. Press the STOP push button. Calibration current adjustment is complete. Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 13 of 17 Printed On : 17/07/19...
  • Page 14: Specifications

    Temp Storage -10°C ~ 60°C Humidity 20% - 90% Non condensing Altitude 0 to 3000 Metres. IP Rating: Operating IP33 Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 14 of 17 Printed On : 17/07/19...
  • Page 15: Product Disposal Instructions

    Business users should contact their suppliers and check the terms and conditions of the purchase contract and ensure that this product is not mixed with other commercial waste for disposal. Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 15 of 17...
  • Page 16: Product Warranty

    Intelligent Charging Limited only obligation shall be to repair or replace such products that have proved to be faulty. Intelligent Charging Limited shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use, or the inability to use the product. The customer shall determine the suitability of this product for its intended use, and the customer assumes all risks and liability whatsoever in connection herewith.
  • Page 17 LSU80A : Load Support Unit Operators Manual This page is intentionally left blank Copyright Material of Intelligent Charging Limited © 2018 Doc: DWG1061-11-R2 LSU80A Operators manual.odt Page 17 of 17 Printed On : 17/07/19...