Download Print this page
Aktobis WDH-930EEW Operating Manual

Aktobis WDH-930EEW Operating Manual

Building dryer

Advertisement

Quick Links

Building Dryer WDH-930EEW
Dear Customer,
You have chosen a high-quality product. To ensure that you get a lot of enjoyment from this product, here are a few
more tips:
After transport
Since the unit uses refrigerant, improper transport can sometimes occur despite careful instructions on the carton.
Therefore, we ask you to let it stand upright for at least4 hours before using it for the first time so that the refrigerant
in the unit can settle properly again.
In case of any problems:
We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause
for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up
any misunderstanding.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: info@aktobis.de

Advertisement

loading
Need help?

Need help?

Do you have a question about the WDH-930EEW and is the answer not in the manual?

Questions and answers

Summary of Contents for Aktobis WDH-930EEW

  • Page 1 We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up any misunderstanding. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 2 ! Do not make any changes to the unit ! The dehumidifier should not be operated or stored in a room with other burning/heating appliances ! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 3  The unit must be installed according to the national installation regulations.  Do not use any objects, except those permitted by the manufacturer, to accelerate the defrosting process.  Do not drill or burn. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 4 If hot work is to be carried out on the refrigerant equipment or associated parts, suitable fire extinguishing equipment must be readily available. Make sure that a dry powder fire extinguisher or a CO2 fire extinguisher is nearby. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 5 Make sure that gaskets or sealing material are not so worn that they no longer serve their purpose in preventing the ingress of flammable atmospheres. Spare parts must be in accordance with the manufacturer's specifications. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 6 The following procedure should be followed: - Remove the refrigerant - Purge the circuit with inert gas - Deflate - Rinse again with inert gas - Open the circuit by cutting or soldering Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 7 (k) Reconditioned refrigerant shall not be charged into other refrigeration systems unless it has been purified and tested. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 8 When draining oil from a system, this must be done in a safe manner. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 9 Description of the unit parts: Control panel Carrying Blower handle Output Air filter Air intake Connection point Condensation Castors tank Drain hose Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 10: Functional Description

    If you want to stop the timer before the set time has elapsed, set it to zero again! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 11 3.5. Now screw the screw cap tightly back onto the hose outlet. Make sure that everything is properly seated and that no water can leak out at the connections (see diagrams at the beginning of the next page). Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de...
  • Page 12 3.6. Proper drainage of condensation water with hose connection ! Make sure that the hose always has a slight slope (see the following diagrams). Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 13 It is best to clean the air filter carefully under lukewarm water or with a low- setting (suction power) hoover.  Put the cleaned air filter back in its holder in reverse order - DONE. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 14: Technical Data

    Check that the condensation hose has a slope and is neither kinked nor blocked. Furthermore, check that the building dryer has a straight stand and that the castors are not necessarily in the joints on a tiled floor. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de...
  • Page 15 They will then recycle the appliance. I wish you much pleasure with this appliance. Keep these instructions for use in a safe place ! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 16 Notes: _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...