Novotechnik Messwertaufnehmer OHG Siedle Group Postfach 4220 73745 Ostfildern (Ruit) Horbstraße 12 73760 Ostfildern (Ruit) Telefon 0711/44 89-0 Telefax 0711/44 89-118 http://www.novotechnik.de LENGTH- AND ANGLE- MEASURING SYSTEMS MAP 300/400 CONTENTS (44/00) SAFETY INSTRUCTIONS page WARNINGS EMI-INSTALLATION POINTERS UNIT POINTERS FOUNDATIONS APPLICATION FUNCTION SCHEMATIC DIAGRAM...
Page 2
Novotechnik Messwertaufnehmer OHG Siedle Group FUNCTION MENU page 16 MEASURING RATE DISPLAY FUNCTION DECIMAL POINT TARING VALUE HYSTERESIS VALUE TIME / DATE (OPTION) LIMIT VALUES LIMIT VALUE PROGRAMMING RELAY CONTACT OUTPUT OPTOCOUPLER OUTPUT INFO MENU AUXILIARY OUTPUT ERROR MESSAGES TECHNICAL DATA CONNECTION / OPERATING CONTROLS DESCRIPTION IN/OUTPUTS MAP300_400_en_01.doc...
Novotechnik Messwertaufnehmer OHG Siedle Group SAFETY INSTRUCTIONS WARNINGS • Operating Instructions For a safety operating of this unit you have to read first the operating instructions, the safety in- structions and the warnings. During putting into operation you have to observe the succession of the programming and the operating of the unit like When you are putting the unit into operation you have to look after the succession of the manual.
Novotechnik Messwertaufnehmer OHG Siedle Group EMI-INSTALLATION POINTERS • Signal cables Measuring, signal- or sensor cables, which are connected with the measuring system, must not lie parallel to the power cables. Signal cables have to be screened over the whole length, so also into a steer- or switch cabinet, and the screen connection has to be connected as it is described.
Novotechnik Messwertaufnehmer OHG Siedle Group FOUNDATIONS APPLICATION This series of measuring systems are used to display and monitor length and angle values. The main applications are machine and test equipments. FUNCTION The units MAP 300/400 are microprocessor controled panel-mounting instruments with 3 3/4- to 4 3/4-digit display.
Novotechnik Messwertaufnehmer OHG Siedle Group SCHEMATIC DIAGRAM Z-960292 reference 230 V AC output power supp. 5 V DC 24 V DC anaolg regulator power supp. multiplexer converter 24 V DC auiliary output serial software 4x opto- interface filter isolated input RS 232- calibrat.
Novotechnik Messwertaufnehmer OHG Siedle Group FEATURES The measurement systems have different features. Therefore the service of the units is naturally a little bit different. I. ex. units without limit value comparators have no programmable functions like „LIMIT VALUE FUNCTION“ or „LIMIT VALUE PROGRAMMING“. In special chapters that is addi- tional noted.
Novotechnik Messwertaufnehmer OHG Siedle Group SETUP MENU: ┌─── function display (see OPERATING CONTROLS) limit value function input function interface function measuring range calibration BEGIN value calibration END value analog output function (option) analog output start value (option) analog output stop value (option) LIMIT VALUE FUNCTION [1] In this menu, the switching function (MIN/MAX), the number of limiting value outputs and the pro- gramming block of single limiting values can be selected.
Novotechnik Messwertaufnehmer OHG Siedle Group The limting value function is set at "not program-protected" as standard (L/H). With this, all of the limiting values are firstly changeable. If needed, the limiting value function of individual limiting values can be changed afterwards to "program-protected". Example (series MAP 334/344/444): Four limiting values (setting range only within the calibration range) 1.
Novotechnik Messwertaufnehmer OHG Siedle Group Selection possibilities of the input functions for all inputs: display function display function taring function (static) BCD-inquiry notice the detailed description ! taring function reset HEX-inquiry storage function: display + com- print start, measurement value parator (Hold) storage function: comparator display dark function...
Novotechnik Messwertaufnehmer OHG Siedle Group ternal EEPROM-circuit. Data failures detected with an error message (F11) are not a part of the warranty! 3.2.2 Storage functions The storage function can cause the freezing of the current display value and/or of the comparator state and can also be controlled externally.
Novotechnik Messwertaufnehmer OHG Siedle Group positive, negative or difference. Only after resetting of the activation, is the current measured value displayed and the stored peak value erased. 3.2.5 BCD- or HEX-inquiry For further processing of the displayed value in an SPC, it can also be output in BCD- or HEX- for- mat via the 4 opto-isolated outputs.
Novotechnik Messwertaufnehmer OHG Siedle Group With activation of a logic input, which is programmed for the function „Limit value acceptance", the current measured value is accepted as a limiting value. With this, a change of the limiting value is carried out according to the logic input number, e.g. with logic input IN3, the limiting value SP3 is accepted.
Novotechnik Messwertaufnehmer OHG Siedle Group Programmable dimension / text: The unit of measure with a maximum of 8 characters and the three texts with a maximum of 16 characters can be programmed via the interface. For more information about this, see the interface description.
Novotechnik Messwertaufnehmer OHG Siedle Group CALIBRATION Calibration of the measuring system is carried out in different ways depending on the selected type of measuring range. It is only necessary once or after selection of a new measuring range or possi- bly after the exchange of a potentiometric sensor.
Novotechnik Messwertaufnehmer OHG Siedle Group END value programming [6] After selecting the program routine [6], the END value must be defined. To program the END value, press down the SP>-key and additionally press the -key. Only then is the possibility to carry out changes released.
Novotechnik Messwertaufnehmer OHG Siedle Group FUNCTION MENU With the FUNKTIONS-MENU it`s possible to programm all functions which have to be changed more times at the normal measurement operation. This functions have to be programmed at the first starting time after the SETUP-MENU. MENU ACTIVATING Press in the normal measurement operation the SEL-key for five seconds till the display shows FUNC.
Novotechnik Messwertaufnehmer OHG Siedle Group DECIMAL POINT [C] The decimal point of the measurement display can be adjusted by pressing SP>-key on every -.-.-.-.- place. i.ex.: TARING VALUE [d] The taring value of the measurement display is adjustable over the hole measurement range by pressing -keys.
Novotechnik Messwertaufnehmer OHG Siedle Group LIMIT VALUES MAP 334/344/444 MAP 332/342 MAP 330/340 The devices have four independent limit The devices have two independent The devices have value comparators. The function MIN- limit value comparators. The func- no limit value com- or MAX-control is programmed by the tion MIN- or MAX-control is pro- parators.
Novotechnik Messwertaufnehmer OHG Siedle Group INFO MENU The INFO-MENU is not necessary for the normal operation of the device but there are additional important functions for the documentation of device parameters and test functions available. MENU ACTIVATING Press in the normal measurement operation the SEL-key for five seconds till the display shows FUNC.
Page 21
Novotechnik Messwertaufnehmer OHG Siedle Group [A.] taring value This routine shows the actual taring value. [b.] hysteresis value This routine shows the actual hysteresis value. [C.] interface test In this routine the function of the RS 232-interface can be tested. When the TXD and RXD are open the display shows „OPEN“.
Novotechnik Messwertaufnehmer OHG Siedle Group OPTION: Following routines are only optional available. [P.] analog output function This routine shows the analog output function. [q.] analog output start value This routine shows the analog output start value (0%). [r.] analog output stop value This routine shows the analog output stop value (100%).
Novotechnik Messwertaufnehmer OHG Siedle Group ERROR MESSAGES Errors occurring during operation of the measuring system are displayed directly. Some errors have to be quited by pressing any key. E 21 calibration: BEGIN and END value are first adjustable after pressing SP>- and -key.
Novotechnik Messwertaufnehmer OHG Siedle Group TECHNICAL DATA power supply: 230 V AC (+/-10%), 50/60 Hz, 6 VA optional 110 V AC (+/-10%), 50/60 Hz, 6 VA optional 24 V DC, 6 W (20...30 V) isolated, isolation: 100 V DC display: 5-digit LED measurement display, height 14mm 1-digit LED function display, height 7mm measurement rate:...
Page 25
Novotechnik Messwertaufnehmer OHG Siedle Group debounce time: typ. 10 msec., for logic inputs auxiliary output: ca. 24 V DC, max. 70 mA unstabilized (depend on load, open voltage max. 30 V DC ) comparator: only series MAP 332/334/342/344/444: limit value comparator limit value function MIN/MAX for every limit separatly hysteresis: only series MAP 332/334/342/344/444: programmable,...
Novotechnik Messwertaufnehmer OHG Siedle Group DESCRIPTION IN/OUTPUTS Terminal Function Area AC power supply (AC): L (phase) 230V AC (option 110V) DC power supply (DC): + 20...30V DC supply AC power supply (AC): N 230V AC (option 110V) DC power supply (DC): 0V DC unused C: common relay contact of SP1 and SP2 NC/SP1: Normaly closed contact of limit value relay SP1...