  • Page 1 GB/US . . . . Digital Scale model RS User manual – vers . 101 .00...
  • Page 3: Table Of Contents

    GB . . . . . . . Digital Scale model RS Item no .: 560602 & 560604 1 .00 . . . . . . . . . General provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 .00 .
  • Page 4: General Provisions

    The descriptions and illustrations in these instructions are not binding. Guldmann reserves the right to make changes to the product that they deem to be necessary in order to improve the product, without them being obligated to update this publication.
  • Page 5: Intended Use

    2 .00 Intended use This equipment must be used for weighing a person lifted in a sling for general diagnostic purposes. Application area: at institutions, hospitals and specialised medical clinics. We recommend that the unit be used in surroundings that are not subjected to magnetic disturbances.
  • Page 6: Safety

    2.01 Safety The operators must read this user manual carefully, follow the direc- tions in the manual and learn the correct procedures for the use and maintenance of the digital scale . These user instructions contain important information on the mounting, use and maintenance of the digital scale.
  • Page 7 • The model RS digital scale and the sling are in the VERTICAL POSITION • The personnel must ALWAYS follow and keep their focus on the sling and...
  • Page 8: Use

    2 .02 There are many different mounting possibilities with a digital scale, depend- ing upon the situation in which it is being used. The most common manners of mounting the digital scale are described below. A number of the mounting combinations in the configuration table at the end of this chapter are illus- trated.
  • Page 9 2 . Mounting of adapter hook from lifting hanger to the digital scale Press on the quick release button (3) and fasten the adapter hook (4). Fasten the lifting hanger by inserting the adapter hook (4) on the lifting hang- 3.
  • Page 10: Configuration Table

    Configuration table for Digital scale Lifting capacity, max. 300 kg 300 kg Length 200 mm 200 mm Ceiling hoist Ceiling hoist Product GH1 / GH3 movable Lifter interface Adapter interface top Digital scale RS Adapter for mounting of lifting hanger Hanger interface...
  • Page 11 Configuration table for Digital scale Lifting capacity, max. 300 kg Length 200 mm 260 mm 365 mm Product Mobile lifter GL5 / GL5.1 Mobile lifter GL Universal Lifter interface Adapter interface top Digital scale RS Adapter for mounting of lifting hanger Hanger interface...
  • Page 12: Accessories

    EMC - Information Manufacturer's instructions and declaration - Electromagnetic emissions The model RS electronic digital scale is intended for use in the electromagnetic environ- ments, such as are specified below. The customer or the user must ensure that the scale is used in such an environment.
  • Page 13 Manufacturer's instructions and declaration - Electromagnetic immunity The model RS electronic digital scale is designed to function in electromagnetic environ- ments that are specified below. The customer or the user must ensure that the scale is used in this environment.
  • Page 14 Manufacturer's instructions and declaration - Electromagnetic immunity The model RS electronic digital scale is intended for use in the electromagnetic environ- ments as specified below. The customer or the user must ensure that the scale is used in such an enviroment.
  • Page 15 Recommended distance between RS Digital scale and portable- and mobile radio fre- quency-based communications equipment The model RS digital scale is intended for use in an electromagnetic environment, where radiated RF disruptions are under control. The customer or user of device may assist in...
  • Page 16: Technical Properties

    6 alkaline batteries AAA Operating temperature 0 °C / 40 °C Complies with Directive 2011/65/EU Protection IP54 (Protects against dust and spray) 4 .00 Control panel RS Digital Scale: HOLD = Indicator for Function keys locking of weight On/Off/Zero/Tare = net weight...
  • Page 17: Weighing Mode

    2 . HOLD: Push this key in order to lock the result of the weighing during the weighing phase. Push the HOLD key again to deactivate the HOLD function. 3 . NET: Net weight function 4 . HOLD: Gross weight function 5 .00 Weighing mode Please read the following important guidelines before you read the detailed...
  • Page 18: Settings And Functions

    6 .00 Settings and functions Adjustment of time for automatic shut-off: This function concerns a period of time the digital scale is not in operation. Once the amount of time set has passed, the digital scale will automatically be switched off. Time for automatic shut-off: Programmable 120 sec / 180 sec / 240 sec / 300 sec.
  • Page 19: Settings For The Digital Scale Step-By-Step

    9.00 Replacement of battery The model RS digital scale uses 6 AAA alkaline batteries. Read the instruc- tions below before you use the digital scale. 1. The cover for the battery case is located on the back side 2.
  • Page 20: Error Messages

    Increase the load. 4 . Overload or counter error The load is over the permitted limit, reduce the load and try again. Contact a Guldmann service center if the problem persists. 5. Memory error The programs in the scale contain errors. We ask that you...
  • Page 21: Maintenance And Service

    In order to give the digital scale a better and longer life span it is recommended that regular cleaning be performed. Conduct regular (at least once per year) functional checks on the model RS digital scale in the following manner: •...
  • Page 22: Disposal Of Digital Scale Including Batteries

    Contact your local collection location or V. Guldmann A/S, where the product was purchased, if you desire further information on available possible collec- tion systems.
  • Page 23: Identification Labels

    13.00 Identification labels On the affixed metrological label, the year of production is specified, for example16=2016.17=2017...etc. Units in class lm with measurement func- tion with respect to Directive 93/42/EEC Repetition of metrological verification The digital scale is sold type-approved with the first metrological verification (sign with M).
  • Page 24: Warranty And Service Conditions

    (the “Warranty Period”). If a valid claim is made during the Warranty Period for malfunction or equipment defect, Guldmann will repair or replace the equipment at no additional cost to you. Guldmann retains sole discretion as to whether the equipment will be repaired or replaced.
  • Page 25: Service Or Repair

    Guldmann harmless of and from any and all claims or liability arising as a result of equipment malfunction or misuse. Service or Repair Contact Guldmann Repair for an authorization to return any defective item during the Warranty Period.