Advertisement

EN
INSTRUCTION MANUAL
PELLET STOVE
PELLET INSERT
PELLET STOVE
AIR BOILER
AIRTIGHT STOVES
PELLET STOVE WITH OVEN
PELLET COOKER WITH OVEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Erminy and is the answer not in the manual?

Questions and answers

Summary of Contents for evacalor Erminy

  • Page 1 INSTRUCTION MANUAL PELLET STOVE PELLET INSERT PELLET STOVE AIR BOILER AIRTIGHT STOVES PELLET STOVE WITH OVEN PELLET COOKER WITH OVEN...
  • Page 2 9. The burn pot and the combustion chamber MUST BE CLEANED DAILY. The manufacturer declines any liability for any malfunctioning due to a failure to do so. www.evacalor.com 10. YOU CAN DOWNLOAD THE INSTRUCTION BOOKLET FROM OUR WEBSITE...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 01. PRODUCT SAFETY ............................4 02. GENERAL SAFETY REGULATIONS ......................... 4 03. MINIMUM INSTALLATION REQUIREMENTS ....................5 04. FLUE PIPE ................................6 05. INSTALLATION WARNINGS ..........................8 06. INSTALLATION ..............................9 07. CLEANING AND ROUTINE MAINTENANCE ....................10 08.
  • Page 4: Product Safety

    01. PRODUCT SAFETY SAFETY WARNINGS The stoves were built in compliance according to standard EN13240 (wood stoves), EN 14785 (pellet stoves) and EN 12815 (kitchens and wood-burning stoves)using high quality and non-polluting materials. To make better use of your stove it is advisable to follow the instructions in this booklet. Read this manual carefully before use or any maintenance operation.
  • Page 5: Minimum Installation Requirements

    The metal structure is coated using high temperature paints. When using the appliance for the first few times, unpleasant odours may be given off due to the • paint of the metal parts that is drying: this is in no way dangerous and in such case, simply ventilate the premises. After the first heating cycles, the paint will reach its maximum adhesion and all its chemical and physical features.
  • Page 6: Flue Pipe

    Failure to comply with the installation requirements and/or tampering with the stove may result in: inadequate power and/or abnormal product behaviour, poor flue gas draught, clogging of the fire pit, slow combustion, tank fire, overheating and fire hazard of the stove, fire hazard of the flue gas duct, lack of oxygen in the environment where the stove is located.
  • Page 7 04.1 CHIMNEY COWL A properly installed chimney cowl ensures optimum stove functioning. The anti-downdraught chimney cowl consists of a number of components whose outlet section sum always doubles the vent pipe section. Make sure the chimney cowl is at least 150cm above the roof top so that it is fully exposed to the wind. The chimney cowls must: •...
  • Page 8: Installation Warnings

    05. INSTALLATION WARNINGS By using coaxial tubes, the air will be pre-warmed contributing to improved combustion and lower emissions into the atmosphere. Before installing, the following indications must be met: Select the position where the stove is to be installed and: Arrange the connection to the vent pipe for fume extraction.
  • Page 9: Installation

    INSTALLATION EXAMPLES: T fitting T fitting T fitting T fitting Cleaning direction Cleaning Cleaning direction direction T fitting Cleaning direction EXAMPLES OF INCORRECT INSTALLATION:: inspection inspection External vent with External vent with non- non-closable grid closable grid Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall. 06.
  • Page 10: Cleaning And Routine Maintenance

    07. CLEANING AND ROUTINE MAINTENANCE The stove requires simple and frequent cleaning to guarantee maximum efficiency and correct operation. The Buyer must carry out regular cleaning of the stove following the instructions contained in this Instruction Manual, and in particular must carry out daily cleaning before each ignition or refilling of pellets, the ash drawer, the fire pit and the combustion chamber.
  • Page 11: Anomalies And Possible Solutions

    09. TROUBLESHOOTING PROBLEM CAUSE SOLUTION IT MAY BE NECESSARY TO REPEAT THE FIRST LOAD PHASE A FEW TIMES TO FACILITATE THE APPLIANCE INITIAL FIRST START-UP START-UP AS THE AUGER TUBE IS COMPLETELY EMPTY AND IT MAY TAKE A SPECIFIC PERIOD OF TIME TO FILL. CHECK PLUG AND POWER SUPPLY OR ON/OFF SWITCH POWER OUTAGE FAULTY ELECTRICAL CABLE...
  • Page 12 FAULTY EXCHANGER BLOWER OR BLOCKED CALL TECHNICAL ASSISTANCE. FAULTY THERMOSTAT WITH RESET CALL TECHNICAL ASSISTANCE. FAULTY CONTROL BOARD CALL TECHNICAL ASSISTANCE. ALAR SMOKE PROBE FAULTY FUME SENSOR CALL TECHNICAL ASSISTANCE. SMOKE PROBE ACTIVE ALARM AL2 SMOKE PROBE FUME SENSOR DISCONNECTED CALL TECHNICAL ASSISTANCE.
  • Page 13: Scheduled Maintenance

    10. YEARLY SCHEDULED MAINTENANCE Date 1st maintenance ____________ / ____________ / (Technical Assistance Centre stamp) Date 2nd maintenance ____________ / ____________ / (Technical Assistance Centre stamp) Date 3rd maintenance ____________ / ____________ / (Technical Assistance Centre stamp) 10. CERTIFIES English - 13...
  • Page 14: Installation And Test Certificate

    11. INSTALLATION AND TEST CERTIFICATE CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER: _______________________________________ Retailer's Stamp: STREET/ROAD: ____________________________________________ CITY: _________________________________________ Installer's stamp: POSTAL CODE: ___________________________________________ PROVINCE: _____________________________________ TEL: ____________________________________________ First name: __________________________________________ Delivery date: _________________________________ Last Name: _______________________________________ Delivery date: ____________________________ Address: ______________________Postcode: _____________ Equipment mod.: _________________________________ Location: _________________________________________ Serial number: _____________________...
  • Page 15: Warranty

    The warranty provided shall be subject to the following terms and conditions: The aftersales procedure is managed by our staff, who may be contacted on +39 0438 35469 or by sending an e-mail to assistenza@evacalor.it Our qualified staff will provide you with information concerning technical, installation or maintenance problems.
  • Page 16 Proper waste disposal is important not only for the environment and the health of citizens, but also because this operation leads to a recovery of materials that have significant energy and resource savings. Eva Stampaggi S.r.l. Retailer Stamp and Signature Via Cal Longa Z.I. I - 31028 Vazzola (Treviso - Italy) Tel. +39.0438.740433 rollover lines Fax +39.0438.740821 Email info@evacalor.it English - 16...
  • Page 17 Eva Stampaggi S.r.l. Via Cal Longa Z.I. 31028 Vazzola (TV) ITALIA Tel: +39 0438 740433 Fax: +39 0438 740821 I dati e le caratteristiche indicate non impegnano Eva Stampaggi S.r.l., che si riserva il diritto di apportare le modifiche ritenute opportune senza obbligo di preavviso o di sostituzione. Tutti i diritti riservati.

Table of Contents