IDEC WB2F-100S1B Instruction Sheet

2d code scanner
Hide thumbs Also See for WB2F-100S1B:

Advertisement

Quick Links

INSTRUCTION SHEET
WB2F 2D Code Scanner
Confirm that the delivered product is what you have ordered. Read this
instruction sheet to make sure of correct operation. Make sure that the
instruction sheet is kept by the end user.

SAFETY PRECAUTIONS

In this operation instruction sheet, safety precautions are categorized in order
of importance to Warning and Caution:
Warning notice are used to emphasize that improper may cause severe
personal injury or death.
Caution notices are used where inattentionmightcausepersonalinjuryor
damage to equipment.
・This product is not designed for use in medical equipment, nuclear power,
 railways,aircraft, passenger vehicle equipment, or similar applications
 requiring a high degree of reliability and safety. Do not use the product for
 these applications.
・When using this product in a system that may impact human life, such as in
 the management of chemicals, take the utmost care with a redundant design
 and safety design so that there is no possibility of impacting human life when
 data is mistaken.
・Do not modify , disassemble, or repair this product. There is a risk of serious
 ac cidents such as electric shock, damage, fire, malfunction, and other heave
 accident.
・Do not directly look at the reading window (transparent section) or expose
 any person to it while the LED is illuminated (performing reading operation).
 There is a risk of danger to the eyes.
・This product is for general electronic equipment. Do not use it for applications
 where there is a direct threat to the body or to human life due to malfunction or
 failure.
・Always turn off the power supply before wiring, maintaining, and inspecting the
 product. Otherwise there is a risk of electric shock or failure.
・Do not connect the product to a power supply outside the rated power supply
 voltage range or to an AC power supply. Otherwise there is a risk of explosion
 or burnout.
・Mistakenly wiring the product may cause the internal circuit to be damaged.
 Wire the input and output circuits by referring to "Input and output circuit
 connection example" in article 6. This product is not equipped with a protection
 circuit for a reversed power supply connection, so there is a risk of damage
 when the power supply connection is reversed. Use extreme caution when
 connecting the power supply.
・Avoid parallel wiring of the product's wires in the same conduit or duct with high
 voltage lines or power lines (inverter power lines in particular) as this may
 cause malfunction or damage due to the effect of induction noise.
・If the wires are long and when there is a risk of being affected by power
 sources or solenoids, independently wire the product as a general rule.
・Avoid installing or using the product in the following locations as there is a risk
of malfunction or damage.
1) Near induction equipment or heat sources
2) Locations with many vibrations or shocks
3) Dusty and dirty locations
4) In an atmosphere with hazardous gases such as sulfidizing gas
5) Locations in direct contact with water, oils, or chemicals 
6) Outdoors
・This product is not an explosion-proof product. Confirm that explosion-proof
capabilities are not required when installing the product.
EU Authorized Representative:
IDEC Elektrotechnik GmbH
Heselstuecken 8, 22453 Hamburg, Germany
Manufacturer:
IDEC CORPORATION
2-6-64, Nishimiyahara, Yodogawa-ku,
Osaka 532-0004, Japan
1
1

Type number

WB2F-100S1B

Communication interface

B:RS-232
2
2
B-1945(0)
General specifications
model
WB2F-100S1B
5VDC±0.25V *1  
Rated power supply voltage
 
Consumption Curren
500mA or less (peak 1A or less)
Operation Button
Equipped on unit (tactile switch) x 2
Barcode
50 to 180mm (narrow bar size 0.5mm) *2
Readin
distance
50 to 150mm (cell size 0.5mm) *2
2D code
Focal point
100mm
Field of view
70mm×50mm (at focalpoint)
Number of digits
Barcode
64 digits max
to be read
2D code
7,089 digits max
PCS
0.45 or higher *2
Minimum resolution
0.127mm
Light source
High brightness red LED
Imaging element
CMOS image sensor with grobal shutter
Quad-VGA (1280*960) 36fps
Frame rate
720p(1280*720) 40fps
WVGA(800*480)
60fps
Serial I/F
RS-232(600~115,200bps) *3
Communication
interface
USB
USB2.0 Full-speed 12Mbps (virtual COM) *4
Connection type
13pin DIN type connector 2m
External input
2 circuits
Non-voltage contact(Low active)
Voltage input(VIL:0-1.0V, VIH:4.0-VCC)
4 circuits
External output
NPN open collector (sink)
Max. rating 26.4V DC,50mA
Dielectric strength
500V AC (live part-dead part, 1minute)
Anti-ESD
Contact ±4kV,air ±8kV (IEC61000-4-2)
Ambient usage temperature
0 to 45℃ (no freezing)
Ambient usage humidity
30 to 85%RH (no condensation)
10,000lx or lower (under sunlight)
Ambient usage illumination
6,000lx or lower (under incandescent light)
2,000lx or lower (under fluorescent light)
Ambient usage temperature
-20 to 60℃ (no freezing)
Weight
Approx. 150g
Protective construction
IP65
Certified standards
UL/c-UL Listing, CE marking(self declared), VCCI(Report
of Compliance), FCC(Verification), ICES-003(self declared)
EAN-13/8(including addon), UPC-A/E0/E1(including addon),
Barcode
Symbols
CODE39, Codabar(=NW7), Interleaved 2of5(=ITF),
to be read
Standard 2of5(=Industrial 2of5), Matrix 2of5,
Chinese Post Matrix, COOP 2of5, SCODE, Code93,
Code128, GS1-128(formerly:EAN-128), MSI/Plessey,
Italian Pharm(Code32), CIP39, Tri-Optic, TELEPEN,
Code11, GS1 Databar(formerly:RSS)(Omni-directional,
Truncated, Limited, Expanded), GS1 Databar Stacked
(Omni-directional,Expanded) , IATA 2of5
2D code
QR Code/ GS1 QR Code, Micro QR Code,
DataMatrix(DataCode) / GS1 DataMatrix,
PDF417, Micro PDF417
GS1 composite(CC-A, CC-B, CC-C), Japan Postal
*1 Use only a Listed Power Supply with an output rated 5Vdc and marked LPS or NEC Class 2
for use the WB2F as UL Listing product
*2 By IDEC standard barcode or 2D code
*3 RS232 setting parameters of factory setting are baud rate 9,600bps, data size 8bit, 1 stop bit, 
even parity bit, no flow control
*4 For maintenance interface ( incompartible USB bus power )
3
3

Mounting

・The tightening torque for the product mounting screws is 0.4 to 0.5 N・m.
・Do not overtighten the mounting screws or hit the product with a hammer or
the act that requires excessive stress on the root part of the cable (strongly
pull or bend, etc.) the protective construction will be damaged.
Mounting Bracket (included)
・Do not use the included mounting screws when mounting the product to a
plate with a thickness greater than 2.3 mm.
・Ensure that the screw depth of the mounting screw is 3 to 5 mm.
・When mounting with except using the included mounting bracket, the maximum
mounting hole diameter should be φ 3.4mm.
・Mount the product so that the barcode or 2D code skew angle is that shown
in the following diagram. Reading performance drops drastically if the barcodes
are face-to-face with the optical axis.
(50 to 180mm)
4
9
Usage precautions
 ・The power supply reset time is less than 5 seconds, so use the product 5 seconds
  after turning the power on.
 ・When the load and the unit are connected to different power supplies, always
  turn on the unit's power supply first.
 ・Install the product so that the reading window is not directly exposed to
  sunlight or fluorescent light.
■Cleaning the reading window
  If dust, dirt, or water drops gets on the reading window (transparent section)
  or if it gets scratched, this will affect code reading performance.
  Periodically inspect the reading window (red transparent section) to see if there
  is any dust on it, and when you find dust, clean it off.
 ・To clean the reading window, blow off dust/dirt with an airbrush, and then
  gently wipe it off with a soft-tipped item such as a cotton swab.
 ・Reading performance may drop when the reading window is subject to
  moisture, so wipe it off with a soft cloth to use the product. It may affect the
  material of the optical section, so do not use chemicals on it.
■Cleaning the scanner unit
 Wipe off any dirt on the scanner unit with a soft, dry cloth.
 ・Do not use chemicals. This may alter the case or strip the paint.
 ・When the dirt is particularly bad, wipe it off with a cloth soaked in a neutral
  detergent diluted with water and wrung out thoroughly, and then wipe with a
  soft, dry cloth.
5
5

Installing the driver

・Using the USB interface
To use the USB interface, you must install the dedicated Active USB-COM
port drive (virtual COM port driver) on the host computer. For details on the
installation procedure, refer to the WB2F Userʼs Manual.
The manual can be downloaded from the dedicated site on the IDEC
website. If using this product in an environment where the IDEC homepage
cannot be accessed, please contact IDEC sales representatives.
 
6
6

Wiring, terminal layouts

□Input and output circuit connection example
・External output 0 to 3
OUT
Load
0V
    
(26.4VDCmax.)
□Terminal layout of connectors
・DIN connector
Conductor
Signal
Function
color
name
1
OUT0
External output 0
2
OUT1
External output 1
3
OUT2
External output 2
4
OUT3
External output 3
5
+5V
DC power supply+
6
TXD
RS-232 tranmission data
Product mounting screws (included)
7
IN0
External input 0
SEMS M3 x 6mm(2 screws)
8
IN1
External input 1
9
0V
Power supply- (combined SG)
10
RXD
RS-232 receive data
11
CTS
RS-232 control signal
RTS
RS-232 control signal
12
13
NC
No connection
Note: USB connector is for maintenance. For the RS-232 signals, extend
the cable with a AWG28 or thicker cable with due consideration the drop
in the power supply voltage. If the total cable length exceeds 2.8 m,
this may affect noise resistance.
Note: For the RS-232 interface, connect a shield of cable to ground or 0V
when the communication performance is not good by the noise environment.
WB2F
7
8

Initialization

Optical axis
If you want to initialize the product, read the above barcode in maintenance
mode. All the settings will be restored to the factory defaults.
Turn on this product with the operation button pushed and continue holding the
READ / ENTER button for 5 seconds to switch to maintenance mode. When  
maintenance mode starts, the three status LEDs will all flash. When initialization 
is complete, the three status LEDs will turn off and normal operation mode will
be restored.
8
8

Reading range

Install the product by referring to Appendix A of reading range.
This reading range is a representative example measured under the following
measurement conditions.
・ IDEC standard barcode or 2D code
・ Skew:15°, pitch: 0°, tilt: 0°
・Ambient illumination: 300 to 500 lx
9
9

Part names and dimension

Emitter LED x4
18.5
40.0
36.5
33.0
10
10

Precautions when discarding the product

・External input 0, 1
・When discarding the product, handle it as industrial waste.
5V
11
11

Other important information

R
IN
FCC Regulations
This device complies with Part 15 of the FCC Rules. Operation is subject to the
R
following two conditions:
24VDC
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
・USB connector ( Mini-B )
NOTE: This equipment has been tested and found to comply with the limits for
Pin number Signal name
Function
a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
1
VBUS
Bus power
designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment
2
D-
Data-
generates, uses and can radiate radio frequency energy and, if not installed
3
D+
Data+
and used in accordance with the instruction manual, may cause harmful
NC
No connection
4
interference to radio communications. Operation of this equipment in a
5
GND
Ground
residential area is likely to cause harmful interference in whitch case the user
will be required to correct the interference at his own expense.
DIN connector
USB connector

Canadian Department of Communications Compliance Statement

・CAN ICES-3(A) / NMB-3(A)
5
1
(Unit:mm )
Status LED
Optical Center
USB port
Power LED
Position LED
SELECT button
1.0
READ / ENTER button
10.7
10.5
2-M3 length 5mm or less
(Mounting screw holes)
TCP9386
Cable Length
: 2m
http://www.idec.com
2017.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WB2F-100S1B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IDEC WB2F-100S1B

  • Page 1 UL/c-UL Listing, CE marking(self declared), VCCI(Report installation procedure, refer to the WB2F Userʼs Manual. of Compliance), FCC(Verification), ICES-003(self declared)  product. Otherwise there is a risk of electric shock or failure. The manual can be downloaded from the dedicated site on the IDEC EAN-13/8(including addon), UPC-A/E0/E1(including addon), Barcode Symbols website. If using this product in an environment where the IDEC homepage...
  • Page 2 B-1945(0) Appendix A : Reading range (typical example) 読取範囲(代表例) 读取范围(典型示例)                                (mm) DataMatrix 0.127mm pcs 0.9 DataMatrix 0.5mm pcs 0.9 (mm) Code-39 0.127mm pcs 0.9 Code-39 0.5mm pcs 0.9 EAN-13 0.33mm pcs 0.45...

Table of Contents