We believe that the information contained herein was accurate in all respects at the time of printing. Kvaser AB cannot, however, assume any responsibility for errors or omissions in this text. Also note that the information in this document is subject to change without notice and should not be construed...
Page 2
Kvaser T-Cannector Expansion L User’s Guide 2 (18) (This page is intentionally left blank.) Kvaser AB, Mölndal, Sweden — www.kvaser.com...
Kvaser T-Cannector Expansion L User’s Guide 4 (18) 1 About this manual This manual is intended for Kvaser T-Cannector Expansion L users. This document contains a description of the hardware’s properties and functionality. Kvaser AB, Mölndal, Sweden — www.kvaser.com...
An adjustable CAN termination load (connecting an optional resistor of 120 Ω ) is provided by the Kvaser T-cannector v2 (Base unit) and thus provides an affordable and safe way of terminating the CAN bus when using Kvaser interfaces on a development board.
Kvaser T-Cannector Expansion L User’s Guide 6 (18) 2.2 Major features Acts as a CAN bus hub extension to the Kvaser T-cannector v2 (00776-5) Extends the Kvaser T-cannector v2 to in total eight D-SUB9 socket connectors Adjustable termination via easy-to-use three-way switch (Base unit)
3 Kvaser T-cannector v2 (Base unit) hardware Figure 2: Kvaser T-cannector v2 (Base unit) with D-SUB9 connectors. Kvaser T-cannector v2 (Base unit) is a CAN bus hub with three D-SUB9 sockets (see Figure 3) and one D-SUB9 plug connector (see Figure 4 on Page 8).
The Kvaser T-cannector v2 (Base unit) may be powered from an external DC power supply, via a 2.1 x 5.5 mm connector, providing a power source for Kvaser CAN interfaces. The Kvaser T-cannector v2 (Base unit) may also distribute power via V+ in any of the D-SUB9 connectors.
Kvaser T-Cannector Expansion L User’s Guide 9 (18) Figure 6: Power LED and termination three-way switch on Kvaser T-cannector v2 (Base unit). 3.3 Termination Adjustment The Kvaser T-cannector v2 (Base unit) has an adjustable CAN termination that provides an effective way of terminating the CAN circuit. The optional termination Ω...
Figure 7: Top view of Kvaser T-cannector L (Extension unit). Figure 8: Bottom view of Kvaser T-cannector L (Extension unit). Kvaser T-cannector L (Extension unit) is a CAN bus hub with three plus one D-SUB9 sockets (see Figure 10 on Page 11) and one D-SUB9 plug connector (see Figure 11 on Page 11) designed for connecting to a Kvaser T-cannector v2 (Base unit).
Page 11
Kvaser T-Cannector Expansion L User’s Guide 11 (18) AUX-1 CAN-L AUX-4 SHIELD AUX-2 CAN-H AUX-3 Figure 9: Schematic over the Kvaser T-cannector L (Extension unit). Figure 10: Pinout of D-SUB9 socket. Figure 11: Pinout of D-SUB9 plug. Kvaser AB, Mölndal, Sweden — www.kvaser.com...
Figure 12: Kvaser T-cannector L (Extension unit) connected on top of the Kvaser T-cannector v2 (Base unit). The final step is to connect the assembled Kvaser T-Cannector Expansion L to a Kvaser T-cannector v2 (00776-5) as shown in Figure 13.
In this section you will find technical information about the Kvaser T-Cannector Expansion L and its connectors. 5.1 Technical data In Table 2 below you will find the Kvaser T-cannector v2 (Base unit)’s technical specifications. CAN Connectors 3 sockets, 1 plug (D-SUB9)
Kvaser T-Cannector Expansion L User’s Guide 14 (18) 6 Disposal and Recycling Information When this product reaches its end of life, please dispose of it according to your local environmental laws and guidelines. For information about Kvaser’s recycling programs, visit: https://www.kvaser.com/en/kvaser/recycling-policy.html...
KVASER AB’S WARRANTY SHALL BE LIMITED TO THE CORRECTION OF DEFECTS, AND KVASER AB HEREBY EXPRESSLY DISCLAIMS ANY LIABILITY OVER AND ABOVE THE REFUNDING OF THE PRICE PAID FOR THIS DEVICE, SINCE KVASER AB DOES NOT HAVE ANY INFLUENCE ON THE IMPLEMENTATIONS OF THE HIGHER-LEVEL SYSTEM, WHICH MAY BE DEFECTIVE.
Kvaser T-Cannector Expansion L User’s Guide 16 (18) 7.2 EU Regulatory Compliance EU Declaration of Conformity (DoC) Kvaser AB M¨ o lndal Company Name: City: Aminogatan 25 +46 31 886344 Postal address: Telephone number: 431 53 sales@kvaser.com Postcode: E-mail address:...
Page 17
Kvaser T-Cannector Expansion L User’s Guide 17 (18) EU Declaration of Conformity (DoC) Kvaser AB M¨ o lndal Company Name: City: +46 31 886344 Aminogatan 25 Postal address: Telephone number: 431 53 sales@kvaser.com Postcode: E-mail address: declare that the DoC is issued under our sole responsibility and belongs to the following product:...
Kvaser T-Cannector Expansion L User’s Guide 18 (18) 8 Document Revision History Version history for document UG_98236_t-cannector_v2_l: Revision Date Changes 2021-09-07 Initial version Kvaser AB, Mölndal, Sweden — www.kvaser.com...
Need help?
Do you have a question about the T-Cannector Expansion L and is the answer not in the manual?
Questions and answers