Download Print this page
Solar Gibraltar SDPK Installation Instructions

Solar Gibraltar SDPK Installation Instructions

Advertisement

Quick Links

Installation Instructions for model SDPK
Instrucciones de instalación para el modelo SDPK
Warning: Check for underground cables or pipes before digging
Advertencia: Verifique que no haya cables ni tubos subterráneos antes de cavar.
Tools for Assembly/ Herramientas para ensamblaje
Phillip's Head Screwdriver
Adjustable Wrench
Open-End Wrench
Destornillador Phillips
Llave ajustable
Llave de boca
Parts/ Piezas
Cross-arm
Mounting Plate
Travesaño
Placa de montaje
(6) Screw (Actual Size)
(2) Hex Bolt
(6) Tornillo (tamaño real)
(Actual Size)
(2) Perno
hexagonal
(tamaño real)
Top Post
Bottom Post
Poste Superior Poste Inferior
Step #2/ Paso #2
Step #1/ Paso #1
Attach the Mounting Plate to the
Position the L Brackets as
shown. Attach the L
Cross-Arm using (2) Hex Bolt.
Brackets to the Mounting
Fije la placa de montaje en el
Plate using (2) Screws and
travesaño usando (2) Perno
(2) Hex Nuts.
hexagonal.
Coloque los soportes en L
como se muestra. Fije los
soportes en L a la placa de
montaje usando (2)
tornillos y (2) tuercas
hexagonales.
Tools and Supplies for Installation/ Herramientas y Equipamiento Para Instalación
Concrete
Hormigón
Use of Concrete recommended
Hammer
in areas with loose soil
Martillo
Se recomienda el uso de hormigón
en áreas con suelo blando.
(4) L-Bracket
Pounding Block
Bloque para Martillar
(4) L Soporte
(6) Hex Nut
Black Hex Nut
(6) Tuerca
Tuerca Hexagonal
Negro
hexagonal
Hex Bolt A (Actual Size)
Perno hexagonal A (tamaño real)
Option A / Opción A
Side Mount Standard Size Mailbox
Montaje lateral buzón de tamaño estándar
Customers are required to contact the local post office before installing the mailbox to ensure its correct
placement and height at the street. Generally, mailboxes are installed at a height of 41-45 in. from the road
surface to inside floor of the mailbox or point of mail entry (locked designs) and are set back 6-8 in. from front
face of curb or road edge to the mailbox door.
Es necesario que los clientes se comuniquen con la oficina de correo local antes de instalar el buzón para
asegurar su correcta ubicación y altura en la calle. Generalmente, los buzones se instalan a una altura de 41 a
45 pulgadas del nivel del suelo hasta el piso interior del buzón o punto de entrada (diseños cerrados) y se
colocan entre 6 y 8 pulgadas desde el frente del cordón de la acera o borde de la calle hasta la puerta del
Level
Nivel
buzón.
90 DAY LIMITED WARRANTY
The manufacturer warrants this product against defects in materials and workmanship.
Gibraltar Mailboxes warrants to the original consumer purchaser of this mailbox product for 90 days on which it is originally purchased that it is sold
free of latent defects in materials, parts and workmanship. This warranty is limited to repair or replacement of the defective mailbox product. At the
discretion of Gibraltar Mailboxes, defective products must be returned freight prepaid to Gibraltar Mailboxes' factory, The Solar Group. If the unit is
determined to be defective, it will be repaired or replaced free of charge at Gibraltar Mailboxes' option. Please contact customer service first before
mailing the product. This warranty does not include repair or replacement due to defects caused by abuse, misuse, fire, vandalism, substandard or
Cap
nonconforming installation, contact with brick mortar or destructive weather conditions (includes salt air, road salt or other corrosive materials). This
warranty does not cover the labor or any other cost of removal, reinstallation or replacement of, or as a consequence of, the defective mailbox
Tapa
product. This warranty does not cover field expenses or the cost of any items other than the defective mailbox product. Consequential damages to
property are excluded.
GARANTÍA LIMITADA DE 90 DÍAS
El fabricante garantiza este producto contra defectos en los materiales y en la mano de obra.
(2) Washer
Gibraltar Mailboxes garantiza al consumidor comprador original por un período de 90 días a partir de la fecha de compra original que este buzón no
tiene defectos latentes en sus materiales, piezas ni en su mano de obra. Esta garantía se limita a la reparación o al reemplazo del buzón
(2) Arandela
defectuoso. A discreción de Gibraltar Mailboxes, los productos defectuosos deben ser devueltos con flete prepago a la fábrica Gibraltar Mailboxes,
The Solar Group. Si se establece que la unidad presenta defectos, esta será reparada o reemplazada sin cargo, según lo decida Gibraltar
Mailboxes. Comuníquese con Servicio al Cliente primero, antes de enviar el producto por correo. Esta garantía no incluye la reparación ni el
reemplazo por defectos ocasionados por abuso, uso incorrecto, incendio, vandalismo, instalación indebida o de mala calidad, contacto con
argamasa o por condiciones climáticas perjudiciales (lo que incluye aire salado, sal de carreteras u otros materiales corrosivos). Esta garantía no
cubre el trabajo de mano de obra ni ningún otro costo de remoción, reinstalación o reemplazo de un buzón defectuoso ni como resultado de ello.
Esta garantía no cubre los gastos de campo ni el costo de ningún artículo que no sea el buzón defectuoso. Se excluyen los daños resultantes a la
propiedad.
Option B / Opción B
Side Mount Large Size Mailbox
Montaje lateral buzón de gran tamaño
Option C / Opción C
Bottom Mount Mailbox
Montaje Inferior Buzón

Advertisement

loading

Summary of Contents for Solar Gibraltar SDPK

  • Page 1 This warranty is limited to repair or replacement of the defective mailbox product. At the discretion of Gibraltar Mailboxes, defective products must be returned freight prepaid to Gibraltar Mailboxes' factory, The Solar Group. If the unit is determined to be defective, it will be repaired or replaced free of charge at Gibraltar Mailboxes' option.
  • Page 2 Mailbox Installation/ Instalación del buzón Step #4/ Paso #4 Step #3/ Paso #3 Attach the Cross-Arm Assembly to the Top Post using Hex Bolt A, (2) Washer, and Black Hex Nut. After installation, the Cross-Arm Assembly may need to be adjusted. (Do not over tighten.) Option #1: Side Mounting Fije el conjunto de travesaño al poste superior con perno hexagonal, la Option #2: Bottom Mounting...