Samoa Larius GHIBLI 10:1 HYDRO CLEANER Operating And Maintenance Manual

Low and medium pressure wash pumps for intensive cleaning in hazardous environments

Advertisement

Quick Links

w w w . l a r i u s . c o m
GHIBLI 10:1
Hydro cLeaner
Low and medIum pressure
wasH pumps
For InTensIVe cLeanInG
In HaZardous enVIronmenTs
usaBLe wITH coLd
or HoT waTer up To 90°
Trolley version cod. 98690/1
wall version cod. 98691
drum Version 200L cod. 96661/1
H
O Max 90°
2
EN

Advertisement

Table of Contents
loading

Summary of Contents for Samoa Larius GHIBLI 10:1 HYDRO CLEANER

  • Page 1 w w w . l a r i u s . c o m GHIBLI 10:1 Hydro cLeaner Low and medIum pressure wasH pumps For InTensIVe cLeanInG In HaZardous enVIronmenTs usaBLe wITH coLd or HoT waTer up To 90° Trolley version cod. 98690/1 wall version cod.
  • Page 2 This manual is to be considered as an English language translation of the original manual in Italian. The manufacturer shall bear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian. Due to a constant product improvement programme, the factory reserves the right to modify technical details mentioned in this manual without prior notice.
  • Page 3: Table Of Contents

    GHIBLI 10:1 HYDRO CLEANER GHIBLI 10:1 Hydro cleaner INDEX WARNINGS ..................................2 WORKING PRINCIPLE ..............................3 TECHNICAL DATA ................................4 DESCRIPTION OF THE EQUIPMENT ..........................4 TRANSPORT AND UNPACKING ..........................6 CONDITIONS OF GUARANTEE ...........................6 SAFETY RULES ................................6 GROUNDING ................................7 WORKING ..................................7 SETTING UP AND CONNECTION ..........................8 TYPES OF INSTALLATION ............................8 CLEANING AT THE END OF THE WORK ........................9 ROUTINE MAINTENAINCE ............................9...
  • Page 4: Warnings

    GHIBLI 10:1 HYDRO CLEANER WARNINGS A A A The table below provides the meaning of the symbols used in this manual in relation to using, earthing, operating, maintaining, and repairing of this equipment. • Read this operator’s manual carefully before using the equipment. •...
  • Page 5: Bworking Principle

    GHIBLI 10:1 HYDRO CLEANER WORKING PRINCIPLE GHIBLI 10:1 HYDRO CLEANER pump is a low and medium transmitted through a connecting rod to the material pumping piston which allows to suck water. pressure pneumatic pump for professional use to be used for cleaning with water.
  • Page 6: Ctechnical Data

    GHIBLI 10:1 HYDRO CLEANER TECHNICAL DATA GHIBLI 10:1 HYDRO CLEANER Feeding air pressure 7 bar Max water pressure 70 bar Feeding air inlet 1/2” BSPP Max delivery 12 l/min Material output 3/4" BSPP Max water temperature 90° Parts of the pump in contact with water The disposal of some parts of the pump no more Pumping group: steel stainless steel AISI 303 and 420B usable is a customer’s competence and must be...
  • Page 7 GHIBLI 10:1 HYDRO CLEANER Fig. 2D Pos. Description Pos. Description Trolley Drum Version 200L Lubrificant cap Wall version Pumping group Water inlet hose connection Wheel Water outlet hose connection www.larius.com REV. 01 - 12/2020 - Cod. 150186...
  • Page 8: Etransport And Unpacking

    GHIBLI 10:1 HYDRO CLEANER TRANSPORT AND SAFETY RULES UNPACKING Read carefully and entirely the following instructions before using the product. Please save these • The packed parts should be handled as indicated in the symbols instructions in a safe place. and markings on the outside of the packing.
  • Page 9: Hgrounding

    GHIBLI 10:1 HYDRO CLEANER • (IF PROVIDED) TIGHTEN AND CHECK ALL THE FITTINGS • Don’t place the pail on a non-conductive surface, such as FOR CONNECTION BETWEEN PUMP, FLEXIBLE HOSE AND paper or cardboard, which interrups grounding continuity SPRAY GUN BEFORE USING THE EQUIPMENT. GROUNDING PUMP •...
  • Page 10: Jsetting Up And Connection

    GHIBLI 10:1 HYDRO CLEANER TUNING AND TYPES OF INSTALLATION CONNECTIONS WALL MOUNTING • Ensure that the wall on which you intend to install the pump is suitable to support the weight of the pump and accessories Install at the pump inlet an air pressure regulator and the stresses resulting from the use of the pump itself (it is suggested complete with condensate filter •...
  • Page 11: Lcleaning At The End Of The Work

    GHIBLI 10:1 HYDRO CLEANER CLEANING AT THE END OF THE WORK • Close the water supply (L1) • Drain the water from the pumping circuit by pressing the spraying nozzle (L2) • Shut off the compressed air supply to the pump (L3) •...
  • Page 12: Ntroubleshooting

    GHIBLI 10:1 HYDRO CLEANER TROUBLESHOOTING Problem Possible cause Solution The pump does not start Feeding air is not enough Check the air supply. Increase the diameter of the feeding hose Outlet water line clogged Clean. Disconnect the outlet liquid pipe. Feed pump at minimum pressure and check if the pump starts without the outlet pipe...
  • Page 13: Omanual Reset Of The Pneumatic Motor

    GHIBLI 10:1 HYDRO CLEANER MANUAL RESET OF THE Immediately replace the plug with a usual M8 nut PNEUMATIC MOTOR before the guide rod slides into the cylinder (see illustration below). • The feed air pressure of the pump must never be higher than •...
  • Page 14: Qdisassembly Of The Suction Valve

    GHIBLI 10:1 HYDRO CLEANER DISASSEMBLY OF THE • Check the condition of every part of the motor. SUCTION VALVE • For any replacement of the screws (P5) of the crosspiece (P6), for their reassembly and correct adjustment see the drawing below and the exploded view on page 16. Close the compressed air supply to the pump and release the residual pressure in the plant.
  • Page 15: Rreplacement Of The Lower Gaskets

    GHIBLI 10:1 HYDRO CLEANER REPLACEMENT OF THE • Carefully screw again the fluid cylinder (it is suggested to lay a slight film of vaseline grease on the internal walls of the fluid LOWER GASKETS cylinder). Close the compressed air supply to the pump and release the residual pressure in the plant.
  • Page 16 GHIBLI 10:1 HYDRO CLEANER Fig. 1S • Extract the piston rod from the housing. • Unscrew the packing nut (S4) (use a metal rod with an internal diameter of 6 mm). • Remove the gaskets and packing glands. • For the correct reassembling of the gaskets see the illustration below and the exploded view on page 18. NOTE ATTENTION! FOR THE...
  • Page 18: Tspare Parts - Complete Pneumatic Motor

    GHIBLI 10:1 HYDRO CLEANER SPARE PARTS - COMPLETE PNEUMATIC MOTOR WARNING: always indicate code and quantity for every part required. DRUM VERSION VERSIONE FUSTI Fig. 1Q www.larius.com REV. 01 - 12/2020 - Cod. 150186...
  • Page 19 GHIBLI 10:1 HYDRO CLEANER Pos. Code Descripcion Q. ty Pos. Code Descripcion Q. ty 96663 Complete motor - trolley version 96013 Motor piston 96663/1 Complete motor - wall version 96027 Complete valve screw 96669 Complete motor - drum version 33031 Washe 91603 Handle - drum version...
  • Page 20: Uspare Parts - Complete Pumping Group Split Stainless Steel

    GHIBLI 10:1 HYDRO CLEANER COMPLETE PUMPING GROUP - SPLIT ST. STEEL SPARE PARTS - WARNING: always indicate code and quantity for every part required. CILINDRO CORTO CILINDRO LUNGO SHORT FLUID LONG FLUID CYLINDER CYLINDER 16 A 16 B TIRANTE CORTO TIRANTE LUNGO LONG TIE SHORT TIE...
  • Page 21 GHIBLI 10:1 HYDRO CLEANER Pos. Code Descripcion Q. ty Pos. Code Descripcion Q. ty Short - pumping group - 98006 Washer 98051/3 trolley/wall version 3805 Split pin - Trolley/wall version Long- pumping group - 91386 PTFE gaskets 98050/1 drum version 91338 O-Ring 96073...
  • Page 22: Vspare Parts - Complete Trolley

    GHIBLI 10:1 HYDRO CLEANER SPARE PARTS - COMPLETE TROLLEY WARNING: Always indicate code and quantity for each part required. Fig. 1S Pos. Code Description Q.ty Pos. Code Description Q.ty 96320/3 Complete trolley 91023 Wheel 16272/2 Trolley 91026 16271/2 Trolley handle 8029 Screw 16954/2 Stainless steel fixing plate...
  • Page 23: Wspare Parts - Air Group - Trolley Version

    GHIBLI 10:1 HYDRO CLEANER SPARE PARTS - AIR GROUP - TROLLEY VERSION WARNING: Always indicate code and quantity for each part required. Fig. 1S Pos. Code Description Q.ty Pos. Code Description Q.ty 96250/2 Air group complete 96217 Pneumatic supply hose 95230 Nipple 91101...
  • Page 24: Yaccessories

    GHIBLI 10:1 HYDRO CLEANER ACCESSORIES GASKETS TRAVERSE KIT MOTOR KIT Code Description Code Description Code Description 40236 PTFE gaskets kit 40401 Traverse kit screw 40050 Motor kit 40237 Leather gaskets kit 40238 PTFE + leather gaskets kit ATEX CERTIFICATION These safety instructions refer to the installation, use and maintenance of LARIUS GHIBLI series pneumatic piston transfer pumps in high risk environments where potentially explosive gasses or vapours are present.
  • Page 25 GHIBLI 10:1 HYDRO CLEANER Correspondence between hazardous areas, substances and categories HAZARDOUS AREAS CATEGORIES ACCORDING TO THE 94/9/CE DIRECTIVE Gasses, vapours or mists Zone 0 Gasses, vapours or mists Zone 1 2G or 1G Gasses, vapours or mists Zone 2 3G, 2G or 1G SAFETY INSTRUCTIONS FOR INSTALLATION IN HAZARDOUS AREAS Read the indications provided in the user and maintenance manual carefully prior to installation.
  • Page 26 GHIBLI 10:1 HYDRO CLEANER www.larius.com REV. 01 - 12/2020 - Cod. 150186...
  • Page 27: Declaration Of Conformity

    GHIBLI 10:1 HYDRO CLEANER CE DECLARATION OF CONFORMITY Company LARIUS srl Via Antonio Stoppani 21 - 23801 Calolziocorte (LC) ITALY Tel: +39 0341 621152 Fax: +39 0341 621243 E-mail: larius@larius.com Declares under his owns resonsibility that the product: GHIBLI 10:1 HYDRO CLEANER Pneumatic airless pump complies with the - EC Directive 2006/42 Machinery Directive...
  • Page 28 LARIUS srl Via Antonio Stoppani 21 - 23801 Calolziocorte (LC) ITALY TEL. +39 0341 621152 - Fax +39 0341 621243 - larius@larius.com www.larius.com...

Table of Contents