PPE MFT1230C Instructions Manual

PPE MFT1230C Instructions Manual

Mold fluid control systems

Advertisement

MFT1230C & MFT1460C
MOLD FLUID CONTROL SYSTEMS
© Copyright Plastic Process Equipment, Inc 2021
LASTIC
E
8303 CORPORATE PARK DRIVE
A
MACEDONIA, OHIO 44056-2300
216 - 367 - 7000 • FAX: 216 - 367 - 7022
S
TOLL FREE: 800 - 321 - 0562
T
INSTRUCTIONS
Revised 3-18-21
ROCESS
QUIPMENT , INC .
W
6385 MONTESSOURI STREET
E
LAS VEGAS, NEVADA 89113-1186
702 - 433 - 6385 • FAX: 702 - 433 - 6388
S
TOLL FREE: 800 - 258 - 8877
T
FOR
Our PPE Mold Fluid Control Systems are a PPE
exclusive only available from PPE. Do not confuse
these with any other make, model or manufacturer.
www.ppe.com
e-mail: sales@ppe.com
Toll Free: USA, Canada & Mexico
800-362-0706
Order Fax: 800-223-8305

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFT1230C and is the answer not in the manual?

Questions and answers

Summary of Contents for PPE MFT1230C

  • Page 1 INSTRUCTIONS MFT1230C & MFT1460C MOLD FLUID CONTROL SYSTEMS Our PPE Mold Fluid Control Systems are a PPE exclusive only available from PPE. Do not confuse these with any other make, model or manufacturer. © Copyright Plastic Process Equipment, Inc 2021 Revised 3-18-21 www.ppe.com...
  • Page 2: Table Of Contents

    MOLD FLUID CONTROL SPARE PARTS FOR MFT1230C & MFT1460C I N T R O D U C T I O N - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 1 .
  • Page 3: Introduction

    1. INTRODUCTION 1.1 DESCRIBE First of all, thank you for using PPE temperature controller. This series of temperature controllers are our newest designed products. It is small, light, complete function, beautiful appearance, easy to operate, and quick to installation. You can set different temperature, flow rate, and medium used as water or oil.
  • Page 4: Security Information

    Owner should be ensured by adequate supervision that correct safety, installation, maintenance, and operating procedures described in this manual, as well as recognized industry practice, are followed by all personnel. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186...
  • Page 5: Warnings And Cautions

    Please read the manual before starting the machine. The maximum temperature setting value is 120℃. Attention: The unit voltage: 230V, 3Phase Attention: Caution risk of electric shock. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 6: Working Principle

    (EGO) set temperature value, the system starts high temperature alarm and stops; when the cooling water pressure does not reach the set value of the pressure switch, the machine will alarm and stop. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186...
  • Page 7: Installation And Debugging

    Note: the inlet and outlet of cooling water are shown in the figure below. Do not connect them in reverse!When the service temperature is above 100 ° C, the high temperature resistant pipe must be used for the cooling water pipe e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186...
  • Page 8: Power Connection

    2.3 POWER CONNECTION Verify that the connected power supply matches the required specification, and then connect the power supply. Mold entrance Mold export e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 9: Operating Instructions

    OFF automatically, customer can set time based on parameter 3-[F-16] ). Mute ON/OFF Customer won’t hear alarm as switch on. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 10 When phase wire is damaged. 3.6 SETTING BUTTON ITEM Name Explanation Set parameters Enter Increase parameter value Decrease parameter value Rapid cooling e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 11 , the timer will be closed and then shows [OFF]. 7. Blow ON/OFF (1) Blow on: during stop working, press and then blow on. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 12 [AT] for auto-turning. Then, machine will do PID calibration parameter. If the current temp.is flashing alternately, it means under PID calibration parameter. Please note: e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305...
  • Page 13 Lowest limit of CH1 ℃/℉ F02.1 limit, PV<SV-[F02.1] alarm and shows [E-07]- 0-250 temp. (Outlet) [CH1] Time Default switching on time. 0000 0~9999 e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 14 0-350 Upper limit of Upper limit of machine temp.(The parameter ℃/℉ machine temp. of FOH series is 310.) 32-662 e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 15 Magnification 1000 1~1500 magnification value. Correction ℃/℉ OFS2 CH2 Correct wire deviation V.S. deviation of actual Temp. Correction temp signal. 99.9~100.0 e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 16 Lock layer Table 1 & 2 to lock. Set the password by entering Setting password 0~9999 Enter the password in[F-81] [LK-1] e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 17 [E-07]-[CH2] probe 2 below reset the unreasonable parameters. reasonable lower limit Please refer to the common parameter settings of the controller. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 18 Heater failure Replace heater PID calibration [E-15]-[ ATF ] Contactor fault Replace Contactor fault Temperature probe failure Replace the temperature probe e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 19 3.12 COMPLETE FUNCTION e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 20 Interval time of reaction 0-100 receiving correct command? ON: save F-38 Communication back up Communication back up(to EEP rom) OFF: not save e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 21 [F-85], customer can set the password on to enter [F- 84]. 5. Press , back to [F-81] by cycle. 6. Press 2 sec, back to [Temp. setting]. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 22 Open the side cover, screw out the two fixing screws at the lower part of the body side, and then lift up to open the side cover. e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186...
  • Page 23 4.3 SOLENOID VALVE Replacement steps: 1)Open the top cover and the side cover. (Please see 4.1) 2)Remove the solenoid valve or replace it (as shown below). e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 24 3 ) After cleaning the electric heat pipes, installs the electric heat pipes back into the machine in reverse order e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305...
  • Page 25 5. CIRCUIT DIAGRAM 1)Electrical layout(230V) e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 26 2) Circuit diagram(230V) e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 27 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305 TOLL FREE: 800 - 258 - 8877...
  • Page 28 MFT1230C & MFT1460C Electrical symbols Electrical name Model Specifications Remarks Circuit board 1479A 1479A Version ---- Main power switch SLD2 circuit breaker BM63D-3040 40A/3P Fuse FU-10 Contactor SC-E02PM-C AC 220V/50HZ Contactor SC-E2SPM-C AC 220V/50HZ/60HZ Thermal overload TK-E02-C (2.8-4.2)A relay Release...
  • Page 29 MOLD FLUID CONTROL SPARE PARTS FOR MFT1230C & MFT1460C 6. EXPLODED VIEW MODEL: MFT1230C & MFT1460C (Item) PPE Parts No. Description (Qty’) MFT0001 Case Body MFT0002 0~16Kg/cm2&0~230Psi(Pressure Gauge) MFT0003 3/8 (Ball Valve) MFT0004 Heater Housing MFT0005 SUS304 1/2"*1/2"*3/4"(T Tube) MFT0006 SUS304 3/8"(T Tube/Inner Teeth )
  • Page 30 MOLD FLUID CONTROL SPARE PARTS FOR MFT1230C & MFT1460C Electrical and control box spare parts (Item) Parts No. Description (Qty’) MFT0021 Circuit board holder MFT0022 Circuit board MFT0023 Control box MFT0024 buzzer (3~24V /DC) MFT0025 RS485 interface PCB board MFT0026...
  • Page 31 ( ) Use temperature below 120° C, replace the heat medium oil 7.8 CHECK EVERY THREE YEARS ( ) Replace PC board ( ) Replace the circuit breaker e-mail: sales@ppe.com 6385 MONTESSOURI STREET LAS VEGAS, NEVADA 89113-1186 Order Fax: 800-223-8305...

This manual is also suitable for:

Mft1460c

Table of Contents