Summary of Contents for BBG IDS701

  • Page 1 IDS701 Weighing Indicator User manual Manual usuario BBG ref BULL...
  • Page 2 Pls. make sure the weighing display well earthing WARNING The indicator is electrostatic sensitive device, pls. power during electrical connections, internal components touched by hand is prohibited, and please take the anti-static measure Page 1 of 25 Manual usuario BBG ref BULL...
  • Page 3: Table Of Contents

    3.3 Zero function-------------------------------------------------------------------8 3.4 Tare function-------------------------------------------------------------------8 3.5 Accumulating function-------------------------------------------------------9 3.6 Print function-------------------------------------------------------------------9 3.7 Hold function-------------------------------------------------------------------10 4.Calibration-----------------------------------------------------------------------11 4.1 Enter and exit setting--------------------------------------------------------13 4.2 Calibration steps--------------------------------------------------------------15 4.3 Parameter setting-------------------------------------------------------------17 5. Output data format-----------------------------------------------------------18 6. Maintenance--------------------------------------------------------------------21 Page 2 of 25 Manual usuario BBG ref BULL...
  • Page 4: Summary

    IDS701 User Manual 1. Summary IDS701 is specially designed for platform scale with friendly interface, simple operation, steady feature. The Basic function includes Weigh, Peak hold, Print. Communicate, Options are accumulate, Count and animal weighing. 1.1 Main function 》basic weighing function: zero tare retare 》peak hold...
  • Page 5: Outline And Installation Drawing

    6. In order to keep the battery in best using condition, it is suggest that you fully discharge the battery every month, the method is that using the indicator till it is automatically power off. Page 4 of 25 Manual usuario BBG ref BULL...
  • Page 6: Installation

    2. Installation and Calibration 2.1 connection indicator with loadcell IDS701 can connect four pcs 350Ωload cell at most, both four and six wire load cell are ok. To make it simple, we use quick disconnect Or standard plug. As belows Quick disconnect connection 2.2 Connection of interface...
  • Page 7: Connection Between Indicator And Load Cell

    IDS701 User Manual 3. Basic operation 3.1 Key and display IDS701 Weighing indicator display instruction LED display instruction Weighing data display Total accumulating Page 6 of 25 Manual usuario BBG ref BULL...
  • Page 8 Key name Key function Work together with zero, tare, on/off to perform all operations. 1.Clear weight within zero range ZERO 2. Work together with SET to perform Hold and animal-weighing operation. Page 7 of 25 Manual usuario BBG ref BULL...
  • Page 9: Power

    , take the loaded weight as tare, display net weight, Net weight is zero. “tare” “ net” status light is on. At the Tare mode, Press , clear the tare, display gross weight. 3.5 TOTAL Accumulation operation Page 8 of 25 Manual usuario BBG ref BULL...
  • Page 10: Accumulating Function

    Press display. Press to clear the the total weight and exit accumulating mode. 3.6 Print function When the data is stable, connection with printer, it will be printed after press“set”1 second. Page 9 of 25 Manual usuario BBG ref BULL...
  • Page 11: Hold Function

    3.8 10 times high resolution At weighing mode. Press hold it and then press There is one more digital display. It is 10 times high resolution display Page 10 of 25 Manual usuario BBG ref BULL...
  • Page 12: Calibration

    2. Take out the sealing screw on the back of indicator, then press down the “span” Press still and then press enter C01-C39 setting. The key functions in setting: Enter Down Left Power switch. exit setting Page 11 of 25 Manual usuario BBG ref BULL...
  • Page 13 : 0=non-calibration press [C05 zero [C05 1=need calibration zero press press [CAL calibration zero please choose 1 and 。 。 。 。 。 。 ensure scale is empty and “stable” Page 12 of 25 Manual usuario BBG ref BULL...
  • Page 14: Enter And Exit Setting

    If you want to set application Function parameter. Press “PRINT” if you want to exit press “TOTAL” press [C07 Default parameters setting press option:0=non-restore default parameters press 1=restore default parameters Note: after above Page 13 of 25 Manual usuario BBG ref BULL...
  • Page 15 Peak : it shows the max. data, mainly Hold Hold mode function application for materials testing, such as tension and pulling force. Hold:it shows current weight value. Mainly application for animal weighing. Page 14 of 25 Manual usuario BBG ref BULL...
  • Page 16: Calibration Steps

    1= Continuous sending, connect big display Serial interface Communication 2=print method, connect printer. data output 3= Command request method , setting method connect computer. 4=PC continues to sending format, connect computer. option: Page 15 of 25 Manual usuario BBG ref BULL...
  • Page 17 2、 Automatic zero tracking range can not exceed manual zero setting range option:0= close automatic zero tracking time Automatic zero 1=1 second tracking time 2=2 seconds 3=3 seconds Overload option:00= close overload range Page 16 of 25 Manual usuario BBG ref BULL...
  • Page 18: Parameter Setting

    (for bigger, more stable. if the example animal) , loaded weight shake not too you can set this much. The setting is less filter make than 3 weight display more stable Page 17 of 25 Manual usuario BBG ref BULL...
  • Page 19: Output Data Format

    ST= standstill, US= not standstill, OL= overload weight mode, GS=gross mode, NT=net mode weight of positive and negative, “+” or ” –“ measurement unit, “kg” or “lb” Data: weight value, including decimal point carriage return line feed Page 18 of 25 Manual usuario BBG ref BULL...
  • Page 20 Decimal point position XXXXXX0 XXXXXXX XXXXX.X XXXX.XX XXX.XXX Bits3,4 Division State B BitsS function Bits0 gross=0, net=1 Bits1 symbol:positive =0,negative =1 Bits2 overload(or lower zero)=1 Bits3 dynamic=1 Bits4 unit:lb=0, kg=1 Bits5 Constant 1 Page 19 of 25 Manual usuario BBG ref BULL...
  • Page 21 Read gross/net weight weight 5.4Print output format 004 (NO.) Date: XX.XX.XX (year. month. date) Time: XX.XX.XX (hour. minute. second) G.W: 8.88kg (gross,example for two decimal point) 2.88kg (tare) T.W: 6.00kg (net) N.W: Page 20 of 25 Manual usuario BBG ref BULL...
  • Page 22: Maintenance

    Display nnnnnn 3、the cell is bad. connection. 3. checking load cell : check input and output resistance to judge it is good or not. ERR1 during calibration, no Input the correct weight Page 21 of 25 Manual usuario BBG ref BULL...
  • Page 23 3. Do not use indicator outside in rainy, better keep it power off. 4. Power off firstly while plug and unplug Page 22 of 25 Manual usuario BBG ref BULL...
  • Page 24 Division value Max capacity 10000 Empty scales calibration Capacity calibration restore the default parameters Warning tone Automatic power off Power saving mode Hold function Animal weighing mode Upper limit warning 000000 Page 23 of 25 Manual usuario BBG ref BULL...
  • Page 25 3=9600 Manual zero setting Initical zero setting Automatic zero tracking range Automatic zero tracking time Verload range Negative display range Standstill time Standstill range Dynamic filter Noisy filter C30~C40 Reseverd menu Page 24 of 25 Manual usuario BBG ref BULL...
  • Page 26 Power supply EU/DC9V AU/DC9V others User’s manual RS232 quick connecter 3 core Load cell core quick connecter joint Φ0.75mm Power cores supply Bracket Wall mounted bracket Certification Packing list IDS701 Series Page 25 of 25 Manual usuario BBG ref BULL...