Saalio
Face Electrode (item No. 07-01-028-01)
®
Saalio
Forehead Electrode (item No. 07-01-028-04)
®
Saalio
Neck Electrode (item No. 07-01-028-03)
®
Saalio
Universal Electrode (item No. 07-01-028-02)
®
Saalio
Pair of Body Electrodes (item No. 07-01-028-05)
®
User Manual Saalio
Textile Electrodes EN R06
page 1 of 16

Advertisement

Table of Contents
loading

Summary of Contents for SAALMANN Saalio Textile Electrodes

  • Page 1 Instructions for Use ® Saalio Textile Electrodes ☐ ® Saalio Face Electrode (item No. 07-01-028-01) ☐ ® Saalio Forehead Electrode (item No. 07-01-028-04) ☐ ® Saalio Neck Electrode (item No. 07-01-028-03) ☐ ® Saalio Universal Electrode (item No. 07-01-028-02) ☐ ®...
  • Page 2 ® We thank you for putting your trust in Saalmann therapeutic devices. ® The Saalio textile electrodes are not an independent medical device but rather an accessory electrodes for the following Saalio sets and may exclusively only be used with these: ...
  • Page 3: Table Of Contents

    Content 1 Scope of Delivery ..................4 2 Accessories and Spare parts ............... 4 3 Safety Guidelines ..................4 4 Symbol Legend .................... 4 5 Intended Use ....................4 6 Therapeutic Mode of Action ................. 5 7 Indications ....................5 8 Contraindications and Adverse Reactions............
  • Page 4: Scope Of Delivery

    1 Scope of Delivery ® Saalio Face electrode tem No. 07-01-028-01 ® Saalio Forehead electrode item No. 07-01-028-04 ® Saalio Neck electrode item No. 07-01-028-03 ® Saalio Universal electrode item No. 07-01-028-02 ® Saalio Pair of body electrodes item No. 07-01-028-05 To be used with following device configurations: ®...
  • Page 5: Therapeutic Mode Of Action

    6 Therapeutic Mode of Action ® (see user manual for Saalio sets) 7 Indications ® The Saalio therapeutic device is used for the treatment of focal hyperhidrosis (excessive sweating). 8 Contraindications and Adverse Reactions ® (see user manual for Saalio sets) The same contraindications and side effects apply to the textile electrodes as ®...
  • Page 6: Device Setup

    10 Device Setup 10.1 Face, Forehead, Neck and Universal Electrode While the textile electrode (face, forehead, neck or universal electrode) constitutes an electrical contact surface with the device, your hands or feet (treatment tray) are required to serve as second contact surface in order to facilitate the flow of electricity through the body.
  • Page 7 Tip: Use warm tap water. It is much more pleasing to the skin. Counter electrode 4.1. In case you intend to use either both your hands or only one hand as counter electrode, place the treatment tray on a table in front of your body.
  • Page 8 ® User Manual Saalio Textile Electrodes EN R06 page 8 of 16...
  • Page 9: Pair Of Body Electrodes

    Tips:  Use your feet as counter electrode. This frees both hands to change the current strength, correct the position of the textile electrode or initially press it down against individual areas.  Use a mirror to check and optimize the fit of the textile electrode or ask a second person for assistance.
  • Page 10  Use warm tap water. It is much more pleasing to the skin.  Skin contact with the electrodes should be as even as possible in order to facilitate extensive homogenous current feed-in. The wet, heavy electrodes best attach to the skin when in a vertical position. You best lie down for a treatment session so that the electrodes are positioned on top.
  • Page 11: Conducting The Treatment

    11 Conducting the Treatment Basically, treatment with a textile electrode resembles that of hands, feet and armpits. Since the treated body sites or skin, respectively, might react with a more sensitive current perception and might be prone to dehydration, special precautions and recommendations should be observed, particularly at the outset of treatment.
  • Page 12 Should you experience any skin changes, wait until they have completely abated until you re-initiate the treatment with a lower current strength. Treatment Current [mA] Current sensitivity greatly differs from person to person and usually also changes in the course of the treatment (habituation effect). We categorically recommend the use of current strengths above 10 mA for direct current or 15 mA for pulsed current only after you have gained some previous experience (at least 10 sessions).
  • Page 13: Treatment

    11.2 Treatment ® (see instructions for the Saalio sets) Important note: When initiating a therapy session, the first thing to do is always power up the control device. Only then you put on the textile electrode or place your hands or feet in the basin. Once the treatment is finished, you first remove the textile electrode or take your hands/feet out of the basin and as a last step you turn the control device off.
  • Page 14: Transport And Storage

    Make sure you avoid vigorous wringing of the textile electrode, as this could harm it. Put the (still) wet textile electrode in a warm, dry location to ensure it can dry quickly. During the drying phase, the textile electrode shrinks and becomes stiff.
  • Page 15: Warranty

    17 Warranty ® The Saalio textile electrodes, just as sponge pockets and foam inserts, are wear parts and thus excluded from any warranty claims. Should you, however, detect any material or manufacturing defects prior to your first use, please get in touch with us, using the contact information specified in the user manual.
  • Page 16: Manufacturer Contact Information

    21 Manufacturer contact information Saalmann medical GmbH & Co. KG Suedbahnstrasse 34 D-32547 Bad Oeynhausen Germany Internet: www.saalmann-medical.de Mail: info@saalmann-medical.de Phone +49 (0)5731 25450 0 +49 (0)5731 25450 11 ® User Manual Saalio Textile Electrodes EN R06 page 16 of 16...