MGF 932299 User Manual

Leak detector

Advertisement

Quick Links

srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202
MGF
MGF
e-mail: info@mgftools.com –
Art. 932299
FGAS Leak Detector
User Manual
Rev. 3 dated 26/08/2021
1
www.mgftools.com
www.nebulizzare.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 932299 and is the answer not in the manual?

Questions and answers

Summary of Contents for MGF 932299

  • Page 1 Art. 932299 FGAS Leak Detector User Manual Rev. 3 dated 26/08/2021 srl –– Via Chico Mendes, 8 – 43058 Sorbolo Mezzani (PR) Italy – Tel. +39 0521-818301 Fax: +39 0521-818202 e-mail: info@mgftools.com – www.mgftools.com – www.nebulizzare.com...
  • Page 2 Introduction Introduction The FGAS Leak Detector art. 932299 is the most reliable negative corona halogen leak detector at present. We integrate all our experience and customers’ feedback into this product, in hope that it could provide our customer the best price, performance and reliability.
  • Page 3 Technical Specifications Technical Specifications Sensor type: negative corona sensor • Ultimate sensitivity: 3 g/yr • Warm-up Time: 3 • Application: • Detect leaks in other systems and filling vessels. It will respond to all halogenated (including Chlorine and ◦ Fluorine) refrigerants. This includes, but is not limited to: CFCs e.g.
  • Page 4 Operations and installation Operations and installation Operation instruction Power key: long press ON/OFF to turn on/off the detector. • Sensitivity adjustment key: Adjust the sensitivity level according to the detection demands. (Long press this key • could adjust the sensitivity quickly.) Reset key: Reset the background halogen level at the tip to “zero”, any level higher than this “zero”...
  • Page 5 Detecting method Detecting method Halogen leak detector operation method: When the detector is turned on or off by long pressing POWER key, all LED indicator lights are on for three seconds and the detector will automatically reset. After auto-reset, only the first LED indicator light on the left will be on. (Green, batteries fine, orange, batteries getting weak, replace as soon as possible;...
  • Page 6 Additional work may be needed to eliminate possible ambiguity, like other contaminants at the spot may make the detector alarm, Clean the leaking area with dry cloth and blow clean dry air to the leaking area and repeat step 3 above to confirm the leak.
  • Page 7 Conformity Declaration srl - Via Chico Mendes, 8 - 43058 Sorbolo Mezzani (PR) - Italy declares under its own responsibility that the FGAS Leak Detector art. 932299 is in conformity with the following standards or standardized documents: Safety Standards EN 61326-1: 2013 (Electromagnetic Compatibility 2014/30/EU) •...
  • Page 8 Control Certification Control Certification Pursuant to current legislation, it is certified that the instrument has been checked before shipment and that the minimum guaranteed sensitivity is respected. This test is carried out by means of a sample leak calibrated according to the specifications of the EN14624/2012 standard. Date: Signature: srl ––...