4 piece modular kitchen island-bbq with bottom cabinet (21 pages)
Summary of Contents for Thor Kitchen MK04SS304
Page 1
service@thorgroup.us +1 877-288-8099 Outdoor Grill NG Conversion Document Warning: INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR’S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE This conversion kit must be installed by a qualified service technician in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
Page 2
service@thorgroup.us +1 877-288-8099 05.99.008205-000-A0 NG quick coupling NPT ½” 01.17.000106-000-A0 6mm Tool Additional tools like wrench and Philip’s flat screwdriver are needed to help with the NG conversion. Below is LP orifice information, please keep for reference (these orifices are already installed in the product) Explosive # Part # Part Name...
Page 3
service@thorgroup.us +1 877-288-8099 Grill Cabinet Installation Step 1 1. Open Grill cover and take out the Rotisserie, grill racks (3 pcs) and flame tamer;...
Page 4
service@thorgroup.us +1 877-288-8099 2. Then take out 3 pcs tube burners and 1 pc front broiler burner. Use Philip head screwdriver to take out screws shown in the picture;...
Page 5
service@thorgroup.us +1 877-288-8099 3. Use screwdriver to take out the screws next to front infrared broiler burner and front tube burners’ electrodes, then take out the front infrared broiler burner and front burners. 4. Check the front 5 burner knob layout. From left to right are front Broiler burner knob, front left tube burner knob, front middle burner knob, bake Broiler burner knob and front right burner knob.
Page 6
service@thorgroup.us +1 877-288-8099 Step 2 1. Make sure all the front burners are taken out from grill cavity; 2. Use 6mm tool (included in NG conversion kit) to take out original (LP) orifices from the burner valve inside the grill cavity, then put in NG orifices. Detailed orifice information are shown below: NG orifice (included in NG Conversion Kit) Part # Part Name...
Page 8
service@thorgroup.us +1 877-288-8099 Step 3 1. Open outdoor grill cover first and then remove the 4 screws shown in the picture (right side of the back infrared broiler), and then remove the back infrared broiler burner orifice’s protection cover from the back;...
Page 9
service@thorgroup.us +1 877-288-8099 Step 4 1. Regulator Installation: Use 4 pcs 5/32"*8 Philip's flat head screw to install NG regulator part to the back panel of the cabinet; 2. Use Wrench to connect BBQ manifold with NG regulator; 3. Use Wrench to connect NG gas inlet pipe with NG regulator; Connect NG quick coupling to NG pipeline, then connect NG inlet pipe with NG quick coupling.
Page 10
service@thorgroup.us +1 877-288-8099 NG Connection Layout...
Page 11
service@thorgroup.us +1 877-288-8099 Step 5 Safety and Performance Check after NG Conversion: 1. All the distance between electrode needle and burner orifice should be around 3 – 5 mm (0.11 – 0.19 inch) 2. Check all gas connection with Bubble test (detailed procedures please follow Step 4 – 4) 3.
Need help?
Do you have a question about the MK04SS304 and is the answer not in the manual?
Questions and answers