DynaNav Systems Inc. 730 – 11731 Baynes Road Pitt Meadows. BC, Canada, V3Y 2B3 www.dynanav.com THIS MANUAL CONTAINS HELPFUL HINTS ON: Installation and Operation Guide for DynaFlow 2 System DynaFlow 2 Control and Management system...
The system can be installed as a standalone system using the DynaFlow 2 HMI Touchscreen with GPS. It also can be interfaced to other GPS Systems to give the flow data to the DynaFlow 2. It has the capability to interface to KZ Flow Valves, Linear Electric Actuators, Electric Pumps and Hydraulic Systems for liquid Flow Control.
Page 3
6. Stopwatch – Resets the Spray Time to zero 7. Change Target Rate - Button that allows the pilot to set the target rate. 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
Page 4
External GPS system to set flow parameters. If Host is available, it will automatically update the Swath Width, Speed and Rate. 18. SHUTDOWN – When finished application- be sure to use this button to Shutdown the DynaFlow 2 before turning off the aircraft Master Switch.
Page 5
USB Data stick to UPDATE using this button. 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
The SENSOR READING OFFSET is for calibrating the zero point of the Pressure Transducer. For all the later Transducers, the pressure should show -5PSI during Suck Back. 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
Page 7
ERROR COUNT shows the number of Error Packets. If the communication is good, this ERROR COUNT should stay at 0. The LAST SENTENCE shows the last packet sent by the Host Device. 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
Page 8
SIMPLE BY DESIGN – FLEXIBLE IN APPI\LICATION Wiring Harness Diagrams Overview The diagrams attached to appendix are for the interconnect wiring of the DynaFlow 2 system. All wires and connectors on the harnesses are supplied and Mil Specification. Supplied Parts List...
• GPS is a GNSS Engine is less than 0.1 second latency and presented at ten position solutions per second or better. Specifications Environmental: Physical: DynaFlow 2 Touchscreen Operating Temp: -30 to +50 degrees C. Width: 7.0 ins (17.85 cm) Storage Temp: -40 to +70 degrees C.
SIMPLE BY DESIGN – FLEXIBLE IN APPI\LICATION Cutout Size 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
Page 12
Normal operation of the Valve requires the boom pressure to go higher than the Boom Pressure setting to go active. 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
Page 13
Boom Pressure Sensor (Digital), if installed will give a digital feedback of your boom pressure. If using a DynaNav systems DynaFlow Digital Boom Pressure sensor, you can set the pressure at which the GPS marking will be on/off. This pressure setting should be significantly above the check valve pressure as well as significantly below the operating pressure range of the boom.
Some Fans have a variable pitch system. These can be set up to have an actuator to control the pitch thus control the flow of the liquid. Usually, these systems have a fan brake for On/Off control. 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...
Page 15
SIMPLE BY DESIGN – FLEXIBLE IN APPI\LICATION Configurations – Some Examples 730 – 11731 BAYNES ROAD, PITT MEADOWS, BC, CANADA, V3Y 2B4 PHONE: 604-465-0009 WEB PAGE: www.dynanav.com EMAIL: airag@dynanav.com FAX: 604-465-0084...