FULGOR DPA 4 User And Installation Manual

FULGOR DPA 4 User And Installation Manual

Digital power amplifier

Advertisement

Quick Links

DPA 4
DIGITAL POWER AMPLIFIER
USER AND INSTALLATION GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPA 4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FULGOR DPA 4

  • Page 1 DPA 4 DIGITAL POWER AMPLIFIER USER AND INSTALLATION GUIDE...
  • Page 2 USE PRECAUTIONS WARNING: To reduce the risk of electric shock, do not remove the cover (or rear panel). Inside, there are no parts that can be repaired by the user; Entrust the repair to qualified personnel. CAUTION: To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture. This symbol, when displayed, indicates the presence of a non-insulated hazardous voltage inside the body of the device - sufficient voltage to pose a risk of electric shock.
  • Page 3 Grounding or polarization: • Precautions should be taken to ensure that grounding and polarization of the device are not affected. • The metal parts of the equipment are connected to ground via the power cord. • If the power socket does not have a ground connection, contact a qualified electrician to connect the grounding device through the terminal.
  • Page 4 Failures caused by improper use or tampering are excluded from the warranty. Fulgor Service s.n.c. Establishes by means of return verification the declared defect, related to proper use, and the effective validity of the guarantee;...
  • Page 5: General Description

    GENERAL DESCRIPTION DPA, acronym of Digital Power Amplifier, is a class D power unit designed for specifica applications in sound renforcement field, wherever quality, robusteness and reliability are required. Equipped with XLR input connectors and BF balanced output with Euroblock, DPA is also equipped with a pre-calibrated volume control on the rear side (all of them leaves the factory calibrated with the same power) and with LEDs on the front side that indicate power on/protection (blue/red color), VuMeter (green normal level, yellow -3db and red clipping).
  • Page 6: Power Supply

    FULGOR SERVICE laboratory. Alway remove the plug from 230VAC electric socket before removing the fuses and, in any case, before opening the carpentry.
  • Page 7 DPA4 COMMANDS AND FUNCTIONS 1. BLUE/RED LED – switching on and protection: blue everything is OK / red malfunction of indicated channel 2. VuMeter (green signal, yellow -3dB, red Clip) 3. ON/OFF – power button 4. POWER IN – IEC IN for 230VAC power supply 5.
  • Page 8: Volume Control

    VOLUME CONTROL As we said in the first pages of this guide, all DPA leave the factory calibrated with the same power and equipped with a pre-calibrated volume control on the rear. However, it is possible to connect an external potetiometer for each input, with which you adjust the volume of each single channel.
  • Page 9 BRIDGE USE To use this mode, two BF inputs must be connected in parallel and use a “+” of a output channel and a “-“ of the other (see image). Do not drop under 8Ω impedance. OPTIONAL TR150 OUTPUT TRANSFORMER TR150 is a autotransformer that allows you to adjust the DPA output impedance with lines that have different impedances.
  • Page 10: Warranty Certificate

    / or point of sale at which the product was purchased. FULGOR SERVICE has also set up a toll-free number 800-804067. By calling this number we will be able to collect your reports regarding warranty issues and possibly arrange direct return / repair methods.
  • Page 11: Product Data

    The guarantee is provided by: FULGOR SERVICE snc., Via Caduti del lavoro 58, 19021 Arcola - La Spezia. For each dispute, the Forum of La Spezia will have sole jurisdiction.
  • Page 12 According to art. 7 of Legislative Decree 196/2003 You have the right, at any time, to obtain from the Data Manager the information on the processing of your data, the manner and purpose and the logic applied to The Data Controller is the legal representative of FULGOR SERVICE snc., Via Caduti del lavoro 58, 19021 Arcola - La Spezia.