Ortech DWOS Quick Start Manual

Ortech DWOS Quick Start Manual

Sensor switches

Advertisement

Quick Links

Sensor Switches
MODEL
DWOS
INSTALLATION GUIDE
1. Connect lead wires as shown in WIRING DIAGRAM (see fig.2): Black lead to Line (Hot), Red lead
to Load wire, White lead to Neutral wire, Green lead to Ground
2. Gently position wires in wall box, attach sensor switch to the box
3. Mount device "TOP" up
4. Restore power at circuit breaker or fuse, wait ONE minute
5. Remove the small cover plate (see fig.1)
6. Locate the adjustment knobs on the control panel to perform test and adjustment (see fig.1)
7. Replace the small cover plate after testing and adjustment
8. Attach the wallplate
OPERATION
The Sensor Switch is programmed independently for either Occupancy
Mode or Vacancy Mode depending on the Band Switch position under
the control panel cover. Some might call the Vacancy mode as "Manual
On Occupancy Mode".
Manual ON/OFF Button
By Pushing the Control Panel Cover, the Load can be turned ON/OFF under either OCC or VAC mode (see fig.3)
Turning On the Load under Occupancy Mode
Load automatically turned ON when occupancy is detected
Turning On the Load under Vacancy Mode
Manual ON/OFF Button has to be pushed to turn ON the Load
Automatic Turning OFF the Load
Under either mode, the Sensor keeps the Load ON until no motion is detected plus the set time delay, then turns OFF automatically. Under VAC
mode, the Load can turn ON automatically if motion is detected within the first 30 seconds
Manual Turning OFF the load
By Manual ON/OFF Button, the Load can be turned OFF under either OCC or VAC mode. Under OCC Mode, if you press manual ON/OFF button
first, the sensor switch returns to normal until set-time finished
NOTE: For DWOS, there is night light behind the Fresnel Lens as follows:
OFF — The Night Light keeps on constantly
OCC — The Night Light will not work
VAC — The Night Light will turn ON under occupancy when load is off. Conversely, the NIGHT LIGHT will turn OFF when load is ON
info@ortechindustries.com
www.ortechindustries.com
WARNING
WARNING — TURN OFF THE CIRCUIT BREAKER BEFORE INSTALLATION.
1. The SENSOR SWITCH is for INDOOR USE ONLY
2. Do not exceed electrical ratings
CAUTION
PLEASE READ INSTRUCTION BEFORE COMMECING INSTALLATION AND RETAIN FOR FUTURE
REFERENCES. Electrical products can cause death or injury, or damage to property. If in any doubt
about the installation or use of this product, consult a competent electrician.
13376 Comber Way
Surrey BC V3W 5V9
fig.1
375 Admiral Blvd
,
Missisauga
ON L5T 2N1
Instruction Manual
fig.2
fig.3
1-888-543-6473
1-888-541-6474

Advertisement

loading

Summary of Contents for Ortech DWOS

  • Page 1 By Manual ON/OFF Button, the Load can be turned OFF under either OCC or VAC mode. Under OCC Mode, if you press manual ON/OFF button first, the sensor switch returns to normal until set-time finished NOTE: For DWOS, there is night light behind the Fresnel Lens as follows: OFF — The Night Light keeps on constantly OCC —...
  • Page 2 Sensor Switches MODEL DWOS Instruction Manual COVERAGE AREA The Coverage range of the sensor switch is specified and illustrated in fig.4. Large objects and some transparent barriers like glass windows will obstruct the sensor's view and prevent detection, causing the light to turn OFF even though someone is still in the detection area.
  • Page 3 Sensor Switches MODEL DWOS Instruction Manual TROUBLESHOOTING The Load is out of control (frequently flashing) 1. It can take up to one minute for initial run 2. Check the wiring connections, especially the Neutral Wiring The Load does not turn ON without LED flashing or LED flashing regardless of motion 1.