STATE-200 Unit
Installation Manual
(P/N: 9423-06I0A-200)
This manual divides into the following sections:
Section 1: General safety information
Section 2: General description of the STATE-200 Unit
Section 3: Installation of the STATE-200 Unit
Section 4: Using the STATE-200 Unit
Section 5: Troubleshooting
Section 6: General Specifications of the STATE-200 Unit
Copyright © VibroSystM Inc., 2011
STATE-200 Installation Manual_Table of Contents - Rev. 0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STATE-200 and is the answer not in the manual?

Questions and answers

Summary of Contents for VibroSystM STATE-200

  • Page 1 Installation Manual (P/N: 9423-06I0A-200) This manual divides into the following sections: Section 1: General safety information Section 2: General description of the STATE-200 Unit Section 3: Installation of the STATE-200 Unit Section 4: Using the STATE-200 Unit Section 5: Troubleshooting Section 6: General Specifications of the STATE-200 Unit Copyright ©...
  • Page 2 Copyright © VibroSystM Inc., 2011 STATE-200 Installation Manual_Table of Contents - Rev. 0...
  • Page 3: Table Of Contents

    GENERAL SAFETY INFORMATION Safety information ..........................GENERAL DESCRIPTION OF THE STATE-200 UNIT Overview of the STATE-200 Unit main components ................INSTALLATION OF THE STATE-200 UNIT Preliminary considerations for installation in a 19” rack or cabinet ............. Required tools and supplies........................
  • Page 4 Copyright © VibroSystM Inc., 2011 STATE-200 Installation Manual_Table of Contents - Rev. 0...
  • Page 5: General Safety Information

    Caution messages identify conditions or practices that could result in permanent loss of data. Warning - Danger Caution To use VibroSystM instruments correctly and safely, read and follow all the safety instructions • or warnings given throughout this manual. To avoid electric shock, personal injury, or death, carefully read the information under “Safety •...
  • Page 6 IEC 5032 AC (Alternating Current) GND or earth ground Protective conductor terminal Electronics common - not linked to earth ground (Shield) cables shield-to-earth ground, frame or chassis terminal - linked to earth ground Copyright © VibroSystM Inc., 2011 General Safety Information - Rev. 1...
  • Page 7: General Description Of The State-200 Unit

    10/100Mbps standard transmission network. Cat 6 STP network cable must be used. This cable allows installation of the unit at a distance of up to 100m from its network switch. The STATE-200 and ZOOM Controller can share a network with other VibroSystM instruments also using Ethernet transmission. Each STATE-200 Unit has 16 input channels, and several STATE-200 units can be installed on a same network.
  • Page 8: Overview Of The State-200 Unit Main Components

    2.1 Overview of the STATE-200 Unit main components The unit is designed to be installed in a properly ventilated rack mount enclosure. Overall enclosure dimensions are: 483 W x 432 D x 133 H (mm) 19” W x 17” D x 5.25” H (inches)
  • Page 9 The backplane is a board which supports up to 16 input modules, and is connected to the brain board. It also converts and distributes power to other components: +/- 15V or + 5V to the input modules, 24V to the measuring chains, and +5V to the brain board. Copyright © VibroSystM Inc., 2011 STATE-200 General Description_Rev. 0...
  • Page 10 200 mA. The maximum total power output for all ports combined is limited to 1 A. Copyright © VibroSystM Inc., 2011 STATE-200 General Description_Rev. 0...
  • Page 11 An Ethernet network interface is provided to allow transmission of data to a ZOOM Controller. Power Input AC-input connection to power supply. A 3 position removable female screw terminal connector allows wiring of AC power input. The STATE-200 Unit should be installed in compliance with national and local electrical code. Protection Fuses (2) The unit relies on dual fuse protection.
  • Page 12 Copyright © VibroSystM Inc., 2011 STATE-200 General Description_Rev. 0...
  • Page 13: Installation Of The State-200 Unit

    Although it is normally delivered as part of a complete system, already installed and pre-cabled in a new rack or cabinet, STATE-200 Units can also be ordered separately, as an addition to an existing installation. 3.1 Preliminary considerations for installation in a 19” rack or cabinet The following guidelines will help you plan your equipment rack configuration: Allow sufficient clearance around the rack or cabinet for maintenance.
  • Page 14: Unit Installation In A 19" Rack Or Cabinet

    In a rack with square 3/8” windows, cage nuts are used. Slide the unit in the rack and use four screws on the front plate to hold it in place. Copyright © VibroSystM Inc., 2011 STATE-200 Installation and Field Wiring_Rev. 0...
  • Page 15: Cabling The State-200 Unit

    3.4 Cabling the STATE-200 Unit Warning - Danger Caution The STATE-200 Unit power supply and grounding connection should be installed in accordance • with national and local electrical code. To ensure protection, the chassis grounding wire must be of a heavier gauge than the grounding •...
  • Page 16: Ethernet Port

    ZOOM controler. Fifteen different types of modules are available for processing distinct types of signals. A STATE-200 unit can accept up to 16 I/O modules. Each port is wired through a 7-position removable mini-connector which allows connection of signal input, shield, and +24VDC output for powering the measuring chain.
  • Page 17 Refer to section "3.5.1 Input wiring and DIP switch setting" on page 18 for details. The two pins are used with some types of input modules for • connection of input signals IN B Hi and IN B Lo. Copyright © VibroSystM Inc., 2011 STATE-200 Installation and Field Wiring_Rev. 0...
  • Page 18: Input Wiring And Dip Switch Setting

    . Copyright © VibroSystM Inc., 2011 STATE-200 Installation and Field Wiring_Rev. 0...
  • Page 19 . Copyright © VibroSystM Inc., 2011 STATE-200 Installation and Field Wiring_Rev. 0...
  • Page 20 . Copyright © VibroSystM Inc., 2011 STATE-200 Installation and Field Wiring_Rev. 0...
  • Page 21 . Copyright © VibroSystM Inc., 2011 STATE-200 Installation and Field Wiring_Rev. 0...
  • Page 22: Module Installation Or Replacement

    3.5.2 Module Installation or Replacement To replace or add a new module, the STATE-200 must be turned off, all connectors unplugged, and the casing extracted from the instrument rack and opened. 1. To remove a connector from an input port or the power input port, loosen the two screws securing the connector to the socket.
  • Page 23: Using The State-200 Unit

    Periodically wipe the case with a damp cloth and mild water-based detergent. Do not use abrasives or solvent. Clean the exterior of the STATE-200 unit only. Do not apply cleaner directly to unit, or allow liquids to enter or spill on the unit.
  • Page 24 Copyright © VibroSystM Inc., 2011 Using the STATE-200 Unit - Rev. 0...
  • Page 25: Troubleshooting

    5.2 STATE-200 Software Verification To fully validate the operation of a STATE-200 unit, you must first start the ZOOM Suite software and create a configuration according to the specifics of the current installation. Refer to the ZOOM Suite Software User Manual.
  • Page 26 If the ZOOM Look service shows the status associated to the STATE-200 unit, with the message Acqui- sition Unit Not OK, one of the following problems may have occured: the configuration does not contains the correct IP address •...
  • Page 27 To solve the problem, you first need to find the STATE-200 address in the DHCP. As an example, we used the Windows Server 2003 DHCP server. Select Control Panel -> Administrative Tools->DHCP: In the example above, only one address is assigned to a STATE-200 unit. However, in a longer list, a combi- nation of elements is used for identification;...
  • Page 28: Configuration Troubleshooting

    Once the IP address assigned to the STATE-200 unit has been located in the list of all the addresses assigned by the DHCP server, use the ZOOM Configuration program to verify the ZOOM configuration. Refer to the ZOOM 6 Look Plug-in User’s Guide.
  • Page 29: Incorrect Sensor Configuration

    To correct the configuration, use the ZOOM Configuration user interface, and change the type of module. Consult the STATE-200 hardware configuration form delivered with the unit.
  • Page 30 Copyright © VibroSystM Inc., 2011 Troubleshooting the STATE-200 Unit_Rev. 0...
  • Page 31: State-200 Unit - General Specifications

    CU10_ isolated Contact Closure (switch, relay or other) — contact closure shorting logic input to ground ; 0 to +10 V (5V input bias through internal pull-up resistor) Copyright © VibroSystM Inc., 2011 STATE-200 Extension Unit_General Specifications - Rev. 0...
  • Page 32: Environmental Characteristics

    A - Height 13.34 mm [5.25 in.] B - Width (front) 48.26 mm [19.00 in.] C - Width (back) 44.25 mm [17.42 in.] D - Depth 45.72 mm [18.0 in.] Copyright © VibroSystM Inc., 2011 STATE-200 Extension Unit_General Specifications - Rev. 0...