Download Print this page

Advertisement

Quick Links

Owner's Manual
Original Instructions
Receiver JS13

Advertisement

loading
Need help?

Need help?

Do you have a question about the JS13 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gree JS13

  • Page 1 Owner's Manual Original Instructions Receiver JS13...
  • Page 2 (5) The final right to interpret for this instruction manual belongs to Gree Electric Appliances, Inc. of Zhuhai.
  • Page 3 Contents 1 Safety Notices (Please be sure to abide) ......1 2 Notices for Application ............2 3 Installation Instructions of Receiver ........3 3.1 Dimension and Assembly of Receiver........3 3.2 Installation Method ..............9 4 Introduction to Display ............11 4.1 Appearance of Receiver ............
  • Page 4 Receiver JS13 1 Safety Notices (Please be sure to abide) WARNING: If not abide strictly, it may cause severe damage to the unit or the people. NOTE: If not abide strictly, it may cause slight or medium damage to the unit or the people.
  • Page 5 Receiver JS13 2 Notices for Application ☆ The power supply mode of each indoor unit must be unified power supply. ☆ Never install the Receiver in a humid place or a place with direct sunlight. ☆ Prevent knocking, throwing, frequent disassembly and assembly of the Receiver.
  • Page 6 Receiver JS13 conflict with the system operation mode, the indoor unit will automatically switch to system mode. ④ The priority of the system mode defaults to the master-slave mode, and only a specific unit has the priority of other system modes.
  • Page 7 Receiver JS13 3.1.1 Selection Requirement for Communication Wire Figure 3-2 Length of Communication Wire Total length of communication wire between Wire size Material Wire material type Remarks indoor unit and standard wired controller L Light/Ordinary Total length of polyvinyl chloride 2×0.75~...
  • Page 8 Receiver JS13 ② The communication wire of the receiver must be selected according to this manual. Prohibit selecting the communication wire which doesn’t comply with the requirement of this manual. 3.1.2 Installation Requirements Never install the receiver in a wet and damp place.
  • Page 9 Receiver JS13 3.1.3 Wiring Requirements There are four kinds of wiring methods between the receiver and indoor unit network: Figure 3-3 One Receiver Controls Figure 3-4 One Receiver and One Wired One Indoor unit Controllers Control One Indoor unit...
  • Page 10 Receiver JS13 Figure 3-5 One Receiver Controls Several Multi VRF IDUs Simultaneously Figure 3-6 One Receiver and One Wired Controller Control Several Multi VRF IDUs Simultaneously...
  • Page 11 Receiver JS13 Wiring instructions: When the receiver is connected with multi VRF unit, the wiring methods as shown in Figure 3-3, Figure 3-4, Figure 3-5 and Figure 3-6 can be adopted, but please pay attention to the follow: ① When one receiver or one receiver and one wired controller control...
  • Page 12 Receiver JS13 3.2 Installation Method When the indoor unit is installed well, select an installation position for the remote signal receiver according to the size of the connection wire and the installation position of the unit, leaving a groove and buried wire slot to install the remote signal receiver and bury the connection wires;...
  • Page 13 Receiver JS13 Figure 3-7 Components of Receiver (reserve Junction box for installation) Table 3.2.1 Introduction of Components (reserve Junction box for installation) ④ ① ② ③ Screw Receiver Junction box installed inside Name Cover M4×25 body the wall(Prepared by user)
  • Page 14 Receiver JS13 Table 3.2.2 Introduction of Components (without Junction box for installation) ① ② ③ Name Cover Tapping screw ST3.5×25 PA Receiver body 4 Introduction to Display 4.1 Appearance of Receiver Figure 4-1 Appearance of Receiver 4.2 Functions Press “On Off” button to turn on or turn off the unit: when the unit is on, set temperature is displayed;...
  • Page 15 Receiver JS13 When using the remote control to set and display the indoor or outdoor temperature, the temperature display area will display indoor or outdoor temperature for 3s and then switch to display the corresponding set temperature value. Under normal operation, when the remote control switches the light on or off, the remote signal receiver will switch between display and black screen.
  • Page 16 Receiver JS13 When error occurs, please turn off the unit and ask professional personnel to maintain it. The following figure refers to the communication error of multi VRF units. Figure 5-1 Communication Error of Multi VRF Units 5.1 Table of Error Codes for Outdoor Unit...
  • Page 17 Receiver JS13 Error Code Content Error Code Content Bad Performance of the Low Water-in Temperature Protection Outdoor Mainboard Outdoor Ambient Temperature High Pressure Sensor Error Sensor Error Inlet Tube Temperature Defrosting Temperature Sensor 1 Sensor Error of Plate Type Error...
  • Page 18 Receiver JS13 Error Code Content Error Code Content Compressor 4 Current Sensor Malfunction of Exit Tube Temperature Error Sensor of Condenser Compressor 5 Current Sensor High and Low Pressure Sensors are Error Connected Inversely Compressor 6 Current Sensor Oil-return 2 Temperature Sensor...
  • Page 19 Receiver JS13 Error Code Content Error Code Content Compressor 6 Over-current Protection of Fan Drive Board Power Protection Supply 4-way Valve Blow-by PV DC/DC Protection Protection System Pressure Over-Ratio Compressor 1 current sensor error Protection 5.2 Table of Error Codes for Indoor Unit...
  • Page 20 Receiver JS13 Error Code Content Error Code Content Quantity Of Group Control Indoor Air Box Sensor Error Indoor Units Setting Error Indoor Units Incompatibility Outdoor Air Box Sensor Error Error Low Air Quanlity Warning IFD Error Outdoor-Indoor Incompatibility Fresh Air-out Sensor Error...
  • Page 21 Receiver JS13 Error Code Content Error Code Content Outlet Pipe Temperature IDU Losing Step Protection Sensor Error Humidity Sensor Error IDU Driver Communication Error Water Temperature Communication Error of IDU Abnormality Master Controller Jumper Cap Error High Temperature of IDU Module...
  • Page 22 Receiver JS13 Debugging Debugging Content Content Code Code Communication error between Wrong Address of Compressor master control and inverter fan Drive Board motor drive Valve Abnormal Alarm Error of Lack of Indoor Unit Grid DRED0 Response Alarm of Indoor Unit Project...
  • Page 23 Receiver JS13 Debugging Debugging Content Content Code Code Electronic expansion valve leak error of thermal storage Outflow of Units IP Address module Protection without shutdown Communication Failure Between error of thermal storage Mode Exchanger and Outdoor module Unit Grid-connection driver board...
  • Page 24 Receiver JS13 Status Status Content Content Code Code Vacuum-pumping Mode Setting of static pressure Operate in Setback Function EVI Operating Mode Heating System compulsory cooling mode Cooling PV GMV Unit export area setting Grid voltage system configuration Anti-condensation temperature Filter Clean Reminder...