Table of Contents

Advertisement

Quick Links

DRIVE - INSTRUCTION MANUAL
SDS Drive Rel. 3
version 01.03.005
• DC-PWM
No part of this publication may be reproduced
or translated, even in part, without prior written
permission from WITTUR.
Subject to change without notice!
www.wittur.com
PM.2.004921.EN
Code
2020-07-22
Edition
Version
808-001-000
SEM ID
info@wittur.com
www.wittur.com
© Copyright WITTUR 2020
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the sematic SDS Rel. 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for WITTUR sematic SDS Rel. 3

  • Page 1 Edition version 01.03.005 Version 808-001-000 SEM ID • DC-PWM No part of this publication may be reproduced info@wittur.com or translated, even in part, without prior written www.wittur.com permission from WITTUR. © Copyright WITTUR 2020 Subject to change without notice! www.wittur.com...
  • Page 3: Table Of Contents

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Preface ���������������������������������������������������������������������������������������������������������������������������������������������������� 7 What is the Sematic Drive System ? ���������������������������������������������������������������������������������������������������������� 8 © Speed profile ......................................9 Default profiles (Param. Code 33) ..............................10 General Features ������������������������������������������������������������������������������������������������������������������������������������ 11 Technical information Sematic Drive System (DC-PWM) ......................11 ©...
  • Page 4 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 6�7�2 Gong While Opening ������������������������������������������������������������������������������������������������������������������ 26 6�7�3 Thermic alarm signal ������������������������������������������������������������������������������������������������������������������ 26 Forced Closing (Nudging) .................................. 26 Fire Fighting (Param. Code 19) ................................. 26 6.10 Double TB ........................................
  • Page 5 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 8�6�4 Option “Output Parameters” ������������������������������������������������������������������������������������������������������� 36 8�6�5 Option “Opening Parameters” ����������������������������������������������������������������������������������������������������� 36 8�6�6 Option “Closing Parameters” ������������������������������������������������������������������������������������������������������� 36 8�6�7 Option “Reversing System” ��������������������������������������������������������������������������������������������������������� 37 8�6�8 Option “Change Password”...
  • Page 7 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Confidentiality agreement Disclaimer The software/hardware “Sematic Drive System ” and all the relevant information, ideas, concepts © and know-how are confidential and the exclusive property of Sematic. All information relevant to this instruction manual and any other support supplied by Sematic must be kept confidential and proprietary to Sematic and shall not to be copied or reproduced in any form whatsoever.
  • Page 8 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual We care about your integrated solution! COMPONENT SYSTEMS Automatic lift doors • Frame and frameless glass doors • • Enhanced car door operator solutions Complete cabins •...
  • Page 9: Preface

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual PREFACE This manual has been drafted taking into account that the Company installing genuine Sematic products will comply with the following necessary requirements: personnel responsible for the installation and/or maintenance of the doors must be familiar with the General and Specific •...
  • Page 10: What Is The Sematic Drive System

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual WHAT IS THE SEMATIC DRIVE SYSTEM © The System consists of: • a Car Door Operator (1) a microprocessor-based Door Controller (2) • The Sematic Drive System automatically controls the opening and closing of the lift doors, monitoring the timing, current variations, ©...
  • Page 11: Speed Profile

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual SPEED PROFILE Opening cycle Opening acceleration Opening high speed Opening deceleration Closing cycle Closing acceleration Closing high speed Closing deceleration Door opening Door closing Open Limit Close limit Closing cycle...
  • Page 12: Default Profiles (Param. Code 33)

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual DEFAULT PROFILES (PARAM. CODE 33) This parameter allows to select one of the five default speed profiles (50%= low performance; 100% = standard performance, 150% = high performance).
  • Page 13: General Features

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual GENERAL FEATURES TECHNICAL INFORMATION SEMATIC DRIVE SYSTEM (DC-PWM) © MAIN SUPPLY VOLTAGE 90-290 Vac (115 V-20%, 230V+26%), 50-60 Hz TYPICAL POWER CONSUMPTION 200 VA PEAK POWER CONSUMPTION 300 VA MOTOR OVERLOAD PROTECTION...
  • Page 14: Signals To/From The Door Controller

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual SIGNALS TO/FROM THE DOOR CONTROLLER SEMATIC DRIVE SYSTEM (DC-PWM) CONNECTIONS © Adjustable internal motor overload protection: The Sematic door drive system estimates the motor temperature and it stop any motor movement in case of overtemperature (Alarm 02 active) .The function is based on i²T algorithm.
  • Page 15 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Field wiring terminal marking in accordance with UL508A Wiring Terminals Connection Typer of Wiring conductor Tightening Wire size temperature number mode connections type torque AWG UL/CUL rating Tightening screw...
  • Page 16 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual INCOMING SIGNALS FROM THE DOOR CONTROLLER Signal Connector Pins Contact type & normal state Note Opening control Ka Connector pins These connections require dry When the Door Controller is (coming from the Main Lift 5-15...
  • Page 17 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual OUTGOING SIGNALS FROM THE DOOR CONTROLLER Signal Connector Pins Contact type & Normal state Notes Opening limit switch contact La Connector pins These connections provide dry The contact is open when the door is 16-17 (voltage free) contact.
  • Page 18: Detector/Photocell/Barriers: Signal-Only Connection To The Door Controller (Direct Connection)

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Warning: to avoid possible induced currents within field wiring, it is recommended to shield the Ka and Kc signals (connector pins 3, 5 and 15) with grounded, shielded cables. Changes made to the factory wiring length or position can damage the EMC system characteristics and is not recommended.
  • Page 19: Complete Connection From Detector Memco E Series To The Door Controller

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual COMPLETE CONNECTION FROM DETECTOR MEMCO E SERIES TO THE DOOR CONTROLLER Alternatives of detector connection MEMCO E 12-18 (RX) with E11-18 (TX) detectors– SDS...
  • Page 20: Instruction Without Handset

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual INSTRUCTION WITHOUT HANDSET Display in Automatic and Manual Mode AUTOMATIC MODE “AUTO” When the Door Controller is working in automatic mode the “AUTO” red led is on, whereas the other two red leds are off. •...
  • Page 21: Programming Mode "Prog

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual PROGRAMMING MODE “PROG” • When the Door Controller is working in “programming mode” the “PROG” red led is on whereas the other two red leds are off. Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming mode.
  • Page 22 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual The following table contains the available parameters, the relevant codes, the description and the allowed modification range: Code param. Default Parameter Range Note Reversing system choice 00, 01, 02 00->...
  • Page 23 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Closed parking mode 00, 01 00 -> Closed skate parking 01 -> Opened skate parking Skate Type 00, 01, 02 00 -> Standard (STD) skate 01 ->...
  • Page 24: Controller Setting For Sds Dc-Pwm

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual CONTROLLER SETTING FOR SDS DC-PWM Param. codes Default SEMATIC Parameter Range Note To be set as for door configuration KN Input 00, 01, 02 00 -->...
  • Page 25 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Advance Setting Opening Parameters* Low start speed 0,10 m/s 0,10 m/s 0,10 m/s 0,10 m/s Acceleration start 0,09 m 0,110 m 0,9 m 0,110 m Acceleration 1 m/s2 1 m/s2...
  • Page 26: Functions Available

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual FUNCTIONS AVAILABLE REVERSING Parameter for managing the reversing function during the door closing cycle. This is divided into: 6.1.1 Reversing system force setting (Param. Code 09) The reverse motion torque parameter sets the sensitivity degree to detect an obstacle during the door closure, thus giving the reopening command.
  • Page 27: No Mlc Signal (Param. Code 02)

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual controller both during movement (Ka signal during the opening cycle, Kc signal during the closing cycle) and during parking (Ka signal while opening, Kc signal while closing). This test setting should only be applied for main lift controllers that are equipped with just 1 relay to command both opening and closing.
  • Page 28: Space Percentage

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 6.7.1 Space Percentage If set, this option allows the Aux Output Relay contacts to send a signal during door opening that relates to a pre-set distance percentage (in comparison to the total door opening) and a signal during the door closing up to the same opening percentage.
  • Page 29: Emergency Opening Device) And Timeout (Param. Code 20)

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual Important Note: the double TB option is the only operation in which the door controller can carry out a self-learning cycle automatically (as a matter of fact it takes place anyhow when a manual self-learning cycle is activated).
  • Page 30: 6�15�6 Pm Position Control (Default 00)

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual activates immediate automatic closure of the skate. During this last operation the Main Lift Controller should however give the closing or opening command to the door operator. 6.15.6 PM position control (Default 00) The sub-parameter allows the selection of two different currents that may be applied to the motor:...
  • Page 31: Im (Reversing Motion) Signal Type (Param. Code 34)

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 6.18 IM (REVERSING MOTION) SIGNAL TYPE (PARAM. CODE 34) This parameter allow to choose 3 different signals to manage the IM (reversing motion) coming from external to main lift controller: 6.18.1 Im pulse.
  • Page 32 PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual ALARMS The Sematic Drive System controller has the ability to diagnose and record a number of defects; such diagnostics is very helpful to the ©...
  • Page 33: Trial Operations Before Start Up The Door Controller

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual TRIAL OPERATIONS BEFORE START UP THE DOOR CONTROLLER To avoid damages, check that the power supply voltage be within the rated values before starting up the door controller Before the lift goes in operation, a self-learning cycle must be carried out and parameters must be set according to the General Options.
  • Page 34: Instruction With Handset

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual INSTRUCTION WITH HANDSET HANDSET (OPTIONAL) Fig. 1 Optional Kit - cod. B147AABX IMPORTANT: handset can only be used on the car roof with the lift in “inspection” mode Recommendation! Although the handset (see picture 1) can be directly connected by the installer/maintenance personnel to the door controller on the car’s roof, the ideal situation is to have a connection with the door controller inside the car (see picture 2).
  • Page 35: User Handset Menus And Submenus

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual USER HANDSET MENUS AND SUBMENUS (*) Access to advanced options with user PASSWORD (**) PC99 is reachable just with SCH or SEM PASSWORD (***) With SCH PASSWORD you can just enter in the interface type selection and to the complete reset parameter...
  • Page 36: Self-Learning Cycle Activation By Means Of The Handset

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual SELF-LEARNING CYCLE ACTIVATION BY MEANS OF THE HANDSET By using the handset to operate a self-learning cycle, interferences with possible signals coming from the main lift controller are avoided Power the system •...
  • Page 37: Option "Parameters

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual The following options are viewed on the display: − PARAMETERS OPENING PARAMETERS − − CLOSING PARAMETERS − REVERSING SYSTEM CHANGE PASSWORD − RESERVED AREA −...
  • Page 38: Option "Mlc Parameters

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 8.6.2 Option “MLC Parameters” The following options are viewed on the display: PC01 MLC TEST • PC02 NO MLC SIGNAL • • PC03 MLC INPUT ALARM For each of the above listed parameter the parameter name is displayed at the top, the current value is displayed at the bottom with the relevant unit measure;...
  • Page 39: Option "Reversing System

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual − “BACK”: press key F1 to restore the MAIN MENU − F2 KEY: to open and close the door, to test the modified profile “DRAW”: press key F3 to update the speed profile drawing −...
  • Page 40: Door Operator Setup

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual DOOR OPERATOR SETUP • Connect the handset to RJ45 connector; • If necessary, using keys ã and ä choose the required language and confirm with the “OK” key Using keys ã...
  • Page 41: Activation Of The Glazed Panel And Heavy Doors Setting By Means Of The Handset

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual • The following options are available: − “BACK”: Press key F1 to restore the menu DOOR CONFIGURATION “MENU”: Press key F3 to restore the MAIN MENU −...
  • Page 42: Maintenance Menu - Diagnostics And Alarm Management

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 10 MAINTENANCE MENU - DIAGNOSTICS AND ALARM MANAGEMENT 10.1 CONSULTING THE MAINTENANCE MENU WITH THE HANDSET • Connect the handset to the RJ45 connector If necessary, using keys ã...
  • Page 43: Controller Software Upgrade

    PM.2.004921.EN - 808-001-000 SDS rel 3 · Edition 22 July 2020 © Drive - Instruction Manual 11 CONTROLLER SOFTWARE UPGRADE • Connect the handset to the RJ45 connector • If necessary, using keys ã and ä choose the required language and confirm with the “OK” key Using keys ã...
  • Page 45 YOUR GLOBAL PARTNER FOR COMPONENTS, MODULES AND SYSTEMS IN THE ELEVATOR INDUSTRY More information about Wittur Group available on-line. a WITTUR brand a WITTUR brand a WITTUR brand...

Table of Contents