55Uk63Xxpsx Pmic Voltage Measurement Point; Mode Name : 55Uk63Xxpsx Test Point And Volt Spec; Pcb Test Point - LG 55UK6500AUA Service Manual

Hide thumbs Also See for 55UK6500AUA:
Table of Contents

Advertisement

55UK63xxPSx PMIC voltage measurement point

Mode Name : 55UK63xxPSx Test Point and Volt Spec

Test Spec
N
Test
Spec
o
name
1
VTERM
1.2V
2
VCC18
1.98V
3
VCOM1
5.33V
4
VCOM2
5.33V
5
P VGL
-7V
6
LS VGL
-15V
7
VGH
30V
8
VST
-15V
9
VGH EVEN
28V/-
15V
10
VGH ODD
28V/-
15V
11
PM VCC
5V
PMCI JIG Point
12
LS VGL
-15V
13
HVDD
8.23V
14
VDD EPI
16.8V
[Unit:Volt]
Min(-5%)
Max(+5%)
1.14
1.26
1.88
2.08
5.06
5.60
5.06
5.60
-6.65
-7.35
-14.25
-15.75
28.50
31.50
-14.25
-15.75
26.60 / -
29.40 / -
14.25
15.75
26.60 / -
29.40 / -
14.25
15.75
4.75
5.25
-14.25
-15.75
7.82
8.64
15.96
17.64

PCB Test Point

⑦VGH
⑤P VGL
⑥LS VGL
③VCOM1
②VCC18
①VTERM
⑩VGH ODD
⑧VST
④VCOM2
⑨VGH EVEN
Copyright © 2018 LG Electronics Inc. All rights reserved.