Download Print this page

Sealey VS0208 Instructions page 3

Brake fluid bleeder 12v

Advertisement

NOTE: When brake bleeding and/or brake fluid changing is complete, test the action of the brake pedal to ensure that the brakes
are working correctly and are not spongy, before taking the vehicle onto the road.
Clutch bleeding procedure.
4.4.
4.4.1.
refer to the relevant vehicle manufacturer's instructions for clutch bleeding procedure.
4.4.2.
if no specific instructions from the vehicle manufacturer exist, the same basic procedures as for brake bleeding can be followed.
4.5.
dispose of all waste brake fluid responsibly. contact your local authority for details.
5. MAINTENANCE
5.1.
Check the brake fluid in the unit before each operation and observe level during operation to ensure that the level never falls
below 3cm. (Top up as required, even during bleeding operation) If fluid level drops enough to allow air into the pump of the unit,
it will be necessary to re-bleed the unit as described in section 4.1
5.2.
the pump in the unit has an automatic over current reset instead of a fuse. (reset will take approximately 2 minutes from switch off)
5.3.
If the pump is not to be used for a long period, providing the cap remains closed, the stored brake fluid in the unit will not deteriorate
over time, due to the dry air inside. Wipe unit clean with a dampened cloth, before storing it away in a safe, dry childproof location.
5.4.
there are no regularly serviceable parts to the unit, it should be returned to an authorised sealey agent for repair if needed.
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500
WEEE REGULATIONs
dispose of this product at the end of its working life in compliance with the eu directive on Waste electrical and electronic equipment
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. contact your local solid
waste authority for recycling information.
ENVIRONMENT PROTECTION
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey Group, Kempson Way, suffolk business Park, bury st Edmunds, suffolk. IP32 7AR