Ruijie RG-WALL1600-X9300 Hardware  Installation And Reference Manual

Ruijie RG-WALL1600-X9300 Hardware Installation And Reference Manual

Next-generation

Advertisement

Quick Links

RG-WALL1600-X9300 Next-Generation Firewall
Hardware Installation and Reference Guide V1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RG-WALL1600-X9300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ruijie RG-WALL1600-X9300

  • Page 1 RG-WALL1600-X9300 Next-Generation Firewall Hardware Installation and Reference Guide V1.3...
  • Page 2 This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain the latest information through the Ruijie Networks website. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
  • Page 3 It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance  Ruijie Networks Website: https://www.ruijienetworks.com/  Technical Support Website: https://ruijienetworks.com/support...
  • Page 4: Product Introduction

    Figure 1-1 Appearance of the RG-WALL1600-X9300 Front and Back Panels The RG-WALL1600-X9300's front and back panels are shown in Figure 1-2. See the description for the detailed parts specified by the numbers in the figure. Figure 1-2 Front and Back Panels of the RG-WALL1600-X9300...
  • Page 5 Port Type Description USB MGMT USB-miniB USB port Console RJ-45 It is connected to the PC so that you can manage the firewall through CLI. USB-A Redundant USB port MGMT RJ-45 It is applied to Web management on PC. The default IP 1 &...
  • Page 6: Preparation Before Installation

    2.1.4 Static Discharge Damage Prevention Although much has been done in RG-WALL1600-X9300 to prevent static electricity, great damage may be caused to the circuitry and equipment when the static electricity exceeds a certain limit. In the communication network of the RG-WALL1600-X9300, electrostatic induction may come from the following sources: External electric field produced by the high-voltage supply cable, lightning, etc;...
  • Page 7 Do not stare into any fiber port under any circumstances, as this may cause permanent damage to your eyes. 2.2 Installation Site Requirements RG-WALL1600-X9300 must be used in the room. To ensure normal operation and a prolonged use life of the equipment, the installation site must meet the following requirements.
  • Page 8 2.2.6 System Grounding Requirements A good grounding system is the basis for the stable and reliable operation of the RG-WALL1600-X9300. It is the key to prevent lightning stroke and resist interference. Please carefully check the grounding conditions on the installation site according to the grounding requirements, and perform grounding properly as needed.
  • Page 9 Air-laid paper, fiber end microscope Meter Multimeter, Errormeter, Optic-power meter RG-WALL1600-X9300 is not shipped with a tool kit. The tool kit is customer-supplied. 2.5 Unpacking Requirements Goods Checklist Two mounting brackets, modules, USB cables, Ethernet cables, two power cables, Console cables,...
  • Page 10: Product Installation

    3.1 Installation Procedure 3.2 Installation Verification The RG-WALL1600-X9300 is complicated equipment, so you must carefully plan and arrange the installation location, networking mode, power supply, and wiring before installation. Verify the following before installation:  The installation location is of a good air flow.
  • Page 11 Note that the space between neighboring standard installation holes is a little smaller than that between an auxiliary installation hole and its neighboring standard installation hole. When installing a guide rail for the RG-WALL1600-X9300 series, ensure that the plane to carry the chassis should be installed on the plane of delimiters (entire-U delimiter) of the two neighboring RUs, as shown in Figure 3-1.
  • Page 12 Levelly lift the RG-WALL1600-X9300 by two people on both sides, and slowly move it to the front of the cabinet. Levelly lift the RG-WALL1600-X9300 to a position slightly higher than the tray or the slide rail of the cabinet, put the equipment onto the tray or the slide rail, and push it into the cabinet.
  • Page 13 Insert the twisted pair with the RJ45 port into the appropriate port according to the identification on the panel of the linecard. Distinguish the crossover cable and straight-through cable. Connect the cables and fibers of each board in sequence. 3.7 Binding the Cables Precautions ...
  • Page 14 Make sure the SFP module is installed properly. Make sure the SFP module is inserted into the slot in the correct direction until it hits the internal stop and is locked in place. Figure 3-2 Verify the SFP module is locked in place with the thumb. Pull the SFP module out without rotating the handle outwards.
  • Page 15 3.10 Replacing Swappable Modules (Optional) Replace a swappable module in any of the following circumstances:  The module is faulty.  The module must be replaced based on networking requirements. Make sure the optical modules connected to both ends of a fiber are the same type while replacing swappable optical modules.
  • Page 16: System Debugging

    4 System Debugging 4.1 Establishing the Configuration Environment The user name and password are admin and firewall respectively. Establishing the Configuration Environment Connect the PC to the console port of the device through the Console cable. Connecting the Console Cable Connect one end of the DB-9 serial connector of the console cable to the serial port of the PC.
  • Page 17 After selecting the serial port, click OK. The Serial Port Parameter Setting window is displayed, as shown in Figure 4-3. Set the baud rate to 9600, data bit to 8, parity check to none, stop bit to 1, and no flow control. Figure 4-3 After setting the serial port parameters, click OK.
  • Page 18 Step 3. Set terminal parameters. The parameters are as follows: baud rate 9600, data bit 8, parity check none, stop bit 1, and no flow control. Choose File > Connect, click New Session in the displayed list, and select Serial in the Protocol dropdown list. Click Next, and the following interface will be displayed.
  • Page 19 After configuring the parameters, click Next, and you can configure the session name. Click OK, and the following interface will be displayed. Figure 4-7 Click Finish, and the following interface will be displayed. Figure 4-8 4.2 Power-on Startup Checking Before Power-on ...
  • Page 20  The console cable is correctly connected; the terminal (can be a PC) used for configuration is already started; the parameters are already configured. Checking After Power-on (Recommended) After power-on, you are recommended to perform the following checks to ensure the normal operation of follow-up configurations.
  • Page 21: Monitoring And Maintenance

    5 Monitoring and Maintenance 5.1 RG-WALL1600-X9300 Monitoring Indicators When the RG-WALL1600-X9300 is running, you can monitor the status of each single-board by inspecting the status LED of the appropriate single-board. Figure 5-1 LED Description Status Description STATUS Green Operational Blinking...
  • Page 22: Troubleshooting

    Fault 1 The system login password is lost. [Fault Description] The login password is forgotten or lost, and so it is not possible to configure the data. [Troubleshooting] Please contact Ruijie technical support. Fault 2 The AC power module does not work.
  • Page 23 Check whether the settings of the serial port on the super terminal are the same as the settings above. If not, modify the serial port configuration parameters. If there is still no information output, please contact Ruijie technical support. Fault 4 Illegible characters are displayed on the console.
  • Page 24: Appendix A Connectors And Connection Media

    7 Appendix A Connectors and Connection Media 1.1000BASE-T/100BASE-TX/10BASE-T Port 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses up to 100m of 100-ohm Category-5 or Supper Category-5 UTP or STP cable.
  • Page 25: Appendix B Cabling Recommendations In Installation

    8 Appendix B Cabling Recommendations in Installation When RG-WALL1600-X9300 is installed in standard 19-inch cabinets, the cables are tied in the binding rack on the cabinet by the cabling rack, and top cabling or bottom cabling is adopted according to the actual situation in the equipment room.
  • Page 26 Figure B-2 Bundling up cables (2)  When cables need to bend, you should first bundle them up. However, the buckle cannot be bundled within the bend area. Otherwise, significant stress may be generated in cables, breaking cable cores. As shown in Figure B-3. Figure B-3 Bundling up cables (3) ...
  • Page 27  The hard power cable should be fastened by the terminal connection area to prevent stress.  Do not use self-tapping screws to fasten terminals.  Power cables of the same type and in the same cabling direction should be bundled up into cable bunches, with cables in cable bunches clean and straight.

Table of Contents