Bristan Wave Single Outlet Touchpad Installation Instructions And User Manual
Bristan Wave Single Outlet Touchpad Installation Instructions And User Manual

Bristan Wave Single Outlet Touchpad Installation Instructions And User Manual

Advertisement

Quick Links

Installation Instructions
and User Guide
Wave Single Outlet Touchpad
Models Covered:
All Wave Showers
Please keep this booklet for future
reference.
Installer, when you have read these
instructions please ensure you leave
them with the user.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wave Single Outlet Touchpad and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bristan Wave Single Outlet Touchpad

  • Page 1 Installation Instructions and User Guide Wave Single Outlet Touchpad Models Covered: All Wave Showers Please keep this booklet for future reference. Installer, when you have read these instructions please ensure you leave them with the user.
  • Page 2: Table Of Contents

    Welcome to your new Bristan Digital Electronic Mixer Shower, featuring a contemporary design, wired electronic controller and digital mixing unit. Bristan’s Digital Electronic Mixer Shower has been designed to be easy to install and use. It has also been designed and tested in the UK to all of the relevant British Standards.
  • Page 3: Important Safety Information

    Digital Electronic Mixer Shower it is essential that you • All products manufactured and thoroughly flush through the supplied by Bristan are safe provided pipe work in order to remove any they are installed, used correctly remaining swarf, solder, etc.
  • Page 4: General Information

    General Information • Remove all packaging and check the contents for damage before starting any installation. • Fitting isolation valves to the inlet feeds is required as close as is practical to the inlet connections for ease of maintenance. • Always switch off the power at the consumer unit and isolate the electrical supply before making any electrical connections or if you have to remove the cover of the Control Panel.
  • Page 5: Specifications

    Specifications Specifications Inlet Connection Inlet Water Temperature 1/2” BSP Male Threaded Working Pressures Hot Water Cold Water Supply Supply Min: 0.1 MPa Max: 0.6 MPa ( 1 bar) (6.0 bar) 65°C Outlet Connection 28°C 1/2” BSP 48°C 10.0 Male 5°C Pressure Pressure Threaded...
  • Page 6: Water Requirements

    Water Requirements This fitting needs to be installed in accordance with the following Installation Requirements and Notes (IRN) to ensure they meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and the Scottish Byelaws 2014. The fitting shall be installed so that its outlet discharges above the spill-over level of any fixed Hose Retainer...
  • Page 7: Water Connections

    It is possible to use a pump to boost a low pressure system to meet the inlet requirements. Note: The pump must be a Bristan Twin-End Negative Head Pump - ST NHPUMP 18TN. Pump installation must be in accordance with the Fitting Instructions supplied with the pump.
  • Page 8: Electrical Requirements

    The Electrical Installation and Circuit Protection of this shower must comply with current I.E.E Wiring Regulations (BS 7671) and Building Regulations (Part P). All products manufactured and supplied by Bristan are safe provided they are installed, used correctly and receive regular maintenance in accordance with these instructions.
  • Page 9: Installation - Mixer Unit

    Installation - Mixer Unit Mounting Find a suitable place for the mixer unit. Find a suitable place for the mixer unit. It must be no further than 1.2m away It must be no further than 1.2m away from a socket & no from a socket &...
  • Page 10: Installation - Wall Outlet/Interface Unit

    Installation - Wall Outlet Fitting a 1/2” female connection at the hole in the wall Choose the location for the wall (not supplied). outlet and create a 25-30mm hole in the wall. Ensure your shower accessories have enough reach from that position.
  • Page 11: Operating The Shower - On

    Operating the Shower On Mode Pause - Press once to pause for 5 minutes, for memory setting press and hold. Increase Flow Rate - To increase the flow rate by 1lpm press once, to continuously increase the flow rate press and hold. Decrease Flow Rate - To decrease the flow rate by 1lpm press once, to continuously decrease the flow rate press and hold.
  • Page 12: Operating The Shower - Off

    Operating the Shower Off Mode (User Setting Memory/Cleaning) Start - Press once, for start up press and hold. Maximum Flow Rate - Press once. Eco Flow Rate - Press once, for cleaning function press and hold. Thermal Disinfection - Press and hold right droplet. Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
  • Page 13: System Set Up/User Customisation

    System Set Up Ensure the shower is in Ensure the shower is in off mode, Continually off mode, Continually hold the Start button. hold the Start button. Allow the shower to run Allow the shower to run water through. water through. User Customisation Whilst the shower is on Whilst the shower is on...
  • Page 14: Maintenance

    Maintenance Filters Clean filters under Clean filters under Isolate the water Isolate the water cold running water cold running water supplies & unscrew supplies & unscrew & reverse step 1. & reverse step 1. connections. connections. Remove both Remove both filters.
  • Page 15: Guarantee/Spares

    Guarantee At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product.
  • Page 16 Issue: B Part Number: WV DVO BC Bristan Group Ltd. Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web: www.bristan.com Email: enquire@bristan.com...

Table of Contents