BUILT-IN LP CONNECTION
When an LP unit is being directly connected to an LP house system, you must follow the
natural gas connection guidelines. The installer must provide the proper gas regulator to
reduce the gas pressure to 11" W.C.
Connection: LP Hose with a Type 1 quick disconnect and regulator. Operating pressure: 11.0" W.C.
To operate your side burner on LP gas utilizing a 20lb type 1 cylinder, then a built-in LP tank
restraint must be installed prior to initial use of the side burner. The Installer must supply ½"
ID Flex hose and fixed pipe and a flare adaptor
Changing the LP cylinder
Ensure the main tank valve is turned off before turning the coupler counter clockwise, the
inlet will then disengage. Remove the inlet from the tank valve opening. Your local LP filling
station should be equipped with the proper equipment to fill your tank.
Do not attempt to remove, repair or replace the regulator/hose assembly. This must be
done by qualified and licensed technician only.
GAS CONNECTION
adapter 3/8" flare
fitting 1/2" NPT female
LP regulator/
hose assembly
base of product
open top manifold
20lb LP tank*
Tank retention
device*
1/2" ID flex hose with
1/2" NPT fittings*
1/2" NPT fixed pipe*
Enclosure wall
*not supplied