Quick Links

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN MANUAL AND ON PUMP.
This is a SAFETY ALERT SYMBOL. When
you see this symbol on the pump or in the
manual, look for one of the following signal
words and be alert to the potential for
personal injury or property damage.
Warns of hazards that WILL cause serious
!
personal injury, death or major property
damage.
DANGER
Warns of hazards that CAN cause serious
!
personal injury, death or major property
damage.
WARNING
Warns of hazards that CAN cause personal
!
injury or property damage.
CAUTION
NOTICE: PLEASE READ AND UNDERSTAND THIS MANUAL
BEFORE OPERATE OR INSTALL THE PRODUCT. IF YOU HAVE
ANY QUESTION, PLEASE CONTACT YOUR DISTRIBUTOR FOR
INSTRUCTION.
THIS MANUAL MUST BE KEPT WITH THE PUMP.
MAINTAIN ALL SAFETY LABELS.
IMPORTANT PRE-INSTALLATION INFORMATION
Hazardous voltage can shock, burn or cause
death. All electrical work must be performed
by a qualified technician. Always follow the
local applicable electrical code.
The pump must be connected to a dedicated
electrical circuit protected by a properly sized
circuit breaker or fuses. Install a disconnect
Control Panel where required by the local
code.
Code questions should be directed to your electrical inspector.
See Chart 1 for specific information.
Always disconnect the power source before
installing or servicing the pump. This motors
come with an automatic thermal overload
protection, this feature may allow an
overheated pump to restart suddenly.
INSTALLATION AND OPERATING INSTRUCTIONS
Water and electricity can be dangerous if
certain precautions are not adhered to.
!
This pump is designed to operate in a safe
way in a water environment; however,
DANGER
improper use and installation can result in
personal harm from electrical shock. Please
pay attention to the following warnings.
Never touch this pump, when it is touching
water, in water, or even in a moist environ-
!
ment. Always unplug (disconnect the electric-
DANGER
ity) when working on or installing the unit.
Do not use this pump with flammable or
explosive liquids such as oil, gasoline,
kerosene, ethanol, etc. Using this pump
with or near flammable liquids can cause an
explosion or fire, resulting in property damage,
serious personal injury and/or death.
Pumping any of the above mentioned liquids
voids the warranty. Always make sure that this
pump is pumping liquid with same composi-
tion as water.
Do not stand in water when the pump is
connected to the power supply.
This pump has been evaluated for use with
!
water only.
CAUTION
NOTICE: This pumps has been designed for working in presence
of water. Working without water will cause severe damage to
the pump.
THOR
sprinkler centrifugal pump

Advertisement

loading

Summary of Contents for Pearl THOR 10

  • Page 1 THOR sprinkler centrifugal pump INSTALLATION AND OPERATING INSTRUCTIONS TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP. This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for personal injury or property damage.
  • Page 2 temporarily wasting the water outdoors or to drain. The pump A qualified electrician must perform all should be operated until the water runs clear, without sand, mud the wiring. or rust. CAUTION This procedure will eliminate the danger of pumping dirty water into the pressure tank and home appliances.
  • Page 3 The volume of water delivered decreases with an increased FLOW / CAUDAL [GPM] suction lift. THOR 10 DISCHARGE PRESSURE - PSI Drilled, bored or dug wells may employ an arrangement as in SUCTION LIFT...
  • Page 4 1.40 11.8 10. MOTOR FACTORY PRE-WIRING PEARL Motors for our THOR Pumps are factory pre-wired at 230 V. WA TER SYSTEMS PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090 FAX: (954) 889 0413 www.pdwatersystems.com |...

This manual is also suitable for:

Thor 15Thor 20