Bi-directional Digital DC Power Meter with built-in USB data logger & adapter
Bi-Directional DC Power Meter with built-in USB data logger & adapter.
The new DPM-3332 is an upgrade version of previous DPM series. It measures current in both direction, using a battery
as the reference, it measures the Charging and Discharging current.
DPM-3332 is a self contained with built in data adapter for data retrieval to PC* via USB port and for real time monitoring.
In addition to USB, it can be connected through optional Bluetooth* for Bluetooth model. The new EEPROM is increased
to 3,600 sets of data.
The direction of current is with reference to the receiving end (output) typically a battery. Current (charging) going to
battery is Positive (+) and current out of battery (discharging) is Negative(-).
The power meter is powered up by 5-60V dc from either side or an external USB power bank for extended measured dc
voltage range of 0-60V.
*Remark:
PC software, driver, software and Bluetooth manual can be downloaded from http://www.manson.com.hk/product/dpm-3332/

Precaution

a. Do not exceed 60A and 60V DC in application of DC Meter.
b. Do not apply 60A DC more than 5 second and non-repeatable within 60 second
c. This meter is designed and made for indoor use only.
d. Do not disassemble or attempt to repair the power meter.
e. If Start up screen does not appear, immediate remove all input and output connections power sources.
f.
It is a good practice to have either input or output terminal connected on the supplied terminal block to prevent
possible short circuiting
g. Double check on the correct polarity. If either input or output connection is in wrong polarity, there is no display on
LCD.
h. Damage to the Power Meter may result if wrong polarity power is applied.
i.
Never short leads connected to either input or output set of leads.
j.
Do not exert pressure on the display to avoid damage to LCD display.
Controls, Indicators & terminals
Bidirectional terminal for simultaneous connections to load & source.
LCD Display
Terminal for battery in bidirectional application.
Scrolling Displays
: Constant displays: V, A, and W.
: Two sets of values for most parameters, the positive value means current going into the
battery
and the negative value means current coming out of the battery .
Parameters : Time period in use , Ah (Amp Hour) , WH(Watt Hour) , Vp (max voltage), Ap
(max.current), Wp( max.Watt), Vm (min.Voltage), Negative : -Ah , -WH, -AP,-Wp back to
Time period in use.
Freeze Scrolling display : Hold and release of any scrolling display by quick press of RESET
button
.
DPM-3332
User Manual
FRONT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPM-3332 and is the answer not in the manual?

Questions and answers

Summary of Contents for Manson Engineering Industrial DPM-3332

  • Page 1 Charging and Discharging current. DPM-3332 is a self contained with built in data adapter for data retrieval to PC* via USB port and for real time monitoring. In addition to USB, it can be connected through optional Bluetooth* for Bluetooth model. The new EEPROM is increased to 3,600 sets of data.
  • Page 2 SIDE  Micro USB socket : Either for connection to PC for data retrieval & real time monitoring. Or for connection to External Power source (such as 5V USB Power Bank) to extend voltage range from 5V-60V to 0V-60V.  Reset Switch : To set the data logging interval from 30 sec to 180 sec.
  • Page 3 Bi-directional Application Connect to PC* *Remark: PC software, driver, software and Bluetooth manual can be downloaded from http://www.manson.com.hk/product/dpm-3332/ Bi-directional Application 3- wire connections...
  • Page 4 Terminal 3 is normally used as a load terminal and Terminal 1 is for input source. The following are some examples for four wire meter connections. Unidirectional application with external dc for 0-60V meter range Unidirectional Application Connect to a PC* *Remark: PC software, driver, software and Bluetooth manual can be downloaded from http://www.manson.com.hk/product/dpm-3332/...
  • Page 5 Operations and Displays Installation of the DC Power Meter First connect the leads to the side that provides the d.c. power to the meter and check for displays in the LCD. If no display shows up in LCD then check for reverse polarity. Connect the remaining leads to complete the installation of DC Power Meter.
  • Page 6 DISPLAY indications 1. On the first power up the display shows the firmware version and factory preset data port mode. 2. Sampling time setting 3. Measured Data Displays The data in the scrolling quadrant: Time period in use, Ah (Amp Hour), WH(Watt Hour), Vp (max voltage), Ap (max.current), Wp( max.Watt), Vm (min.Voltage), Negative: -Ah, -WH, -AP,-Wp back to Time period in use, can be fixed and released by one quick press of the Reset button.
  • Page 7 Charger Data Log Graph Discharger Data Log Graph...
  • Page 8 Specifications Measured Parameters Current Range Amp. -20Amp to 20Amp continuous, 30Amp(-30Amp) max. for 30minus., 60Amp(-60Amp) max. for 5second and non-repeatable within 60 second Voltage Range Volt. 5-60V or 0-60V with external DC source Resolution of V & I 0.01V, 0.01A Scrolling Display of Registered Parameters Ampere Hour (AH) Max.

Table of Contents