Download Print this page

emaux S1000 Manual page 2

Advertisement

3) Replace filter coping and tighten the nut. Take care, do not over-tighten.
4) Connect pump to control valve opening marked PUMP.
5) Make return to pool pipe connection to control valve opening marked RETURN and complete other
necessary plumbing connections, suction lines to pump, waste, etc.
6) Make electrical connections to pump per pump instructions.
7) To prevent water leakage, be sure all pipe connections are tight.
MAIN DIMENSION
DIMENSION TABLE
High
Diameter
Valve Port
A
B
Model
Size
mm
mm
Inch
S1000
1220
1020
2"
S1200
1410
1220
2"
INSTALL/START-UP OF FILTER
1) Be sure correct amount of filter media sand is in tank and that all connections have been made and are
secure.
2) Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve
seal, always depress handle before turning.)
3) Prime and start pump according to pump instructions (be sure all suction and return lines are open),
allowing the filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at
least 1 minute. The initial back-washing of the filter is recommended to remove any impurities or fine sand
particles in the sand media.
4) Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear,
about 1/2 to 1 minute.Turn pump off and set valve to FILTER position and restart pump.The filter is now
operating in the normal filter mode, filtering dirt particles from the pool water.
5) Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and
tighten connections, bolts, nuts, as required.
6) Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending
upon the pump and general piping system.) As the filter removes dirt and impurities from the pool water,
the accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge
reading is 1.5 bar, higher than the initial "clean" pressure you noted, it is time to backwash the filter (see
BACKWASH under filter and control valve functions).
NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually
heavy initial dirt load in the water.
Sand
Kg
620
860
B
2-4
A
REPLACEMENT PARTS OF MULTIPORT VALVE
Key No.
Part No.
1
01013003
Handle (Big)
2
03018008
Pin for Handle
3
01181027
Washer for Handle
4
01051026
2.0" Side Mount Valve Squareness Lid (White)
5
89280301
M6*32 Screw with Nut
01111048
Connector for Pressure Gauge/Stopper
6
02011139
O-Ring
7
89021303
Drain Plug with O'Ring
8
06011029
Oil Pressure Gauge With O-ring (40psi)
9
02020016
O-Ring for 2.0"Union
10
01051033
2.0" Connector(White)
11
01171154
2.0" Union (A/E)
12
01051032
2.0" Union Nut(White)
13
02011009
O-Ring for 2.0" Valve Lid
14
01181002
Washer for spring
15
02011022
O-Ring for 2.0" Valve Rotor
16
03014014
Spring
17
01021002
2.0" Valve Rotor
18
02311003
Spider Gasket
19
01051027
2.0" Side Mount Valve Bottom Body (White)
20
89280104
Sight Glass With O-Ring
21
02011011
O-Ring for Union Tale
22
01051035
2.0" Union Tale (White)
23
01013034
2.0" Union Nut (Black)
24
02020017
O-Ring for Plug
25
01051029
2.0" Side Mount Valve Plug (White)
26
01051195
2.0" Elbow Tube (White)183mm
27
01171035
2.0" Union Adaptor (Metric)
REPLACEMENT PARTS OF FILTER
Key
Part No.
No.
1
01111100
Star-Shaped Nut
2
03042001
Bow-Shaped Metal Bar
3
01161006
Manhole
4
02011155
O-Ring for Manhole
5
89011301
S1000 Filter Tank With Base
5
89011302
S1200 Filter Tank With Base
6
89011303
The Inner Tank System for 1000
6
89011304
The Inner Tank System for S1200
7
01101065
2.0" Tank System Support
8
89010613
Laterals (129mm & 185mm) for S1000
8
89010614
Laterals (129mm & 233mm) for S1200
9
01112038
32-40 inch Filter Base
9
01112039
Base for V1200
10
89010107
Water Drain Set
Maximum 40PSI Indication, Stainless Steel
11
06011029
Casing
12
02011127
O-Ring for Inlet & Outlet
6 Way 2" Valve with Piping Kit, 2" union set
13
88280813W
x 3 and pressure gauge (White)
Product Description
Qty
1
1
2
1
1
3
1
5
10
4
1
1
6
1
7
1
8
8
15
3
3
17
3
18
1
1
19
2
1
20
1
1
22
1
1
1
23
21
1
2
1
2
1
1
3-4
Description
Qty
1
1
1
1
1
1
1
1
1
8
8
1
1
1
1
2
1
9
10
11
12
14
16
13
24
25
26
27

Advertisement

loading

This manual is also suitable for:

S1200