Snell IQOTR40 User Manual

3g/hd/sd-sdi multi-channel fiber transceiver

Advertisement

Quick Links

User Manual
IQOTR40, IQOTR41, IQOTR42,
IQOTR43, IQOTR44, IQOTR45
IQOTR99
3G/HD/SD-SDI Multi-Channel Fiber
Transceiver
snellgroup.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQOTR40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Snell IQOTR40

  • Page 1 User Manual IQOTR40, IQOTR41, IQOTR42, IQOTR43, IQOTR44, IQOTR45 IQOTR99 3G/HD/SD-SDI Multi-Channel Fiber Transceiver snellgroup.com...
  • Page 2: Table Of Contents

    The different versions of the standard product simply have different wavelength fiber transmitters fitted. Issue 1 Rev 2 Page 2 © 2012 Snell Limited...
  • Page 3: Module Description

    Module Description The IQOTR40-45 range converts four single mode fiber optic signals to four 3G/HD/SD-SDI outputs and four 3G/HD/SD-SDI signals to four single mode fiber optic outputs. The unit is available in single or dual width versions with either DIN1.0/2.3, HDBNC or BNC connectors.
  • Page 4: Order Codes

    IQOTR40/41/42/43/44/45/99 www.snellgroup.com Order Codes Versions of the module cards available are: SFP fit options for different wavelength operation. CH1/2 CH3/4 IQOTR40 Dual 1310nm Dual 1310nm IQOTR41 Dual 1550nm Dual 1550nm IQOTR42 1270/1290nm 1310/1330nm IQOTR43 1350/1370nm 1390/1410nm IQOTR44 1470/1490nm 1510/1530nm IQOTR45 1550/1570nm...
  • Page 5: Feature Summary

    High density DIN1.0/2.3 and HDBNC options provide compact space saving single slot solution. • The SFP receivers and transmitters are hot-pluggable – i.e. they may be removed and inserted without removing power from the module. Issue 1 Rev 2 Page 5 © 2012 Snell Limited...
  • Page 6: Technical Profile

    SFP fit not as sold (Yellow), SFP warning active (Yellow flashing), OK (Off) Error Hardware error (Red), SFP alarm active (Red flashing), OK (Off) Input 1-8 SD-OK (Yellow), HD-OK (Green), 3G-OK (Blue), other-OK (White flashing), Bypass (Rate colour flashing), Loss (Red) Issue 1 Rev 2 Page 6 © 2012 Snell Limited...
  • Page 7: Specifications

    3 Gbps SDI, SMPTE 424M, 1.5 Gbps HD-SDI, SMPTE 292M 270 Mbps SDI, SMPTE 259MC / DVB-ASI Connector / format BNC/ 75 Ohm panel jack on standard Snell connector panel Return loss >-15 dB (270 Mbps, 1.5 Gbps) >-10 dB (3 Gbps) Output jitter SD-SDI 0.2 UI (10 Hz) / 0.2 UI (1 kHz)
  • Page 8 1270 nm – 1410 nm and 1470 nm –1610 nm Spectral width (FWHM) 1 nm (max) Output power 2.5 dBm (typ), 5 dBm max Extinction ratio >9:1 (typ) Transmission distance Up to 50 km max Issue 1 Rev 2 Page 8 © 2012 Snell Limited...
  • Page 9: Connections

    SDI inputs to the unit are made via BNC / 75ohm panel jack connectors. Fiber Inputs IQOTR4_78-1A3 and IQOTX8_79-1A3 Fiber inputs from the unit are made via 4 LC connectors. IQOTR4_80-2A3 Fiber inputs from the unit are made via 4 LC connectors. Issue 1 Rev 2 Page 9 © 2012 Snell Limited...
  • Page 10: Sdi Outputs

    SDI outputs to the unit are made via BNC / 75ohm panel jack connectors. Fiber Outputs IQOTR4_78-1A3 and IQOTX8_79-1A3 Fiber outputs from the unit are made via 4 LC connectors. IQOTR4_80-2A3 Fiber outputs from the unit are made via 4 LC connectors. Issue 1 Rev 2 Page 10 © 2012 Snell Limited...
  • Page 11: Card Edge Controls

    Flashes to indicate that an SFP status warning has been activated (e.g. temperature or supply voltage) other than the Rx Power Warning. Good (Green) Illuminates to indicate all SFPs are fitted and functioning correctly. Issue 1 Rev 2 Page 11 © 2012 Snell Limited...
  • Page 12: Controlling The Iqotrxx From The Rollcall Control Panel

    Fiber Transmitter to be fitted for that channel (applies to IQOTR99) or a Fiber Receiver is missing or a Tr ansmitter is fitted by mistake. Issue 1 Rev 2 Page 12 © 2012 Snell Limited...
  • Page 13: System-Setup Screen

    To change a name, type the name in the text field and click S. To return the name to its factory default, click P. Note that Fiber Inputs 1-4 are Inputs 5-8 in this context. Issue 1 Rev 2 Page 13 © 2012 Snell Limited...
  • Page 14: Sdi-Inputs 1-4 Screen

    Select Laser Off On Inp Err to apply a mute to the output if there is no valid signal on its input as defined by the checkboxes; includes signal lost. Select Laser Off to manually apply a mute to the output. Issue 1 Rev 2 Page 14 © 2012 Snell Limited...
  • Page 15 Config 1, the Secondary must be routed in Config 2. Also, to prevent the configuration switching backwards and forwards between configurations, it must also be routed in Config 1. Issue 1 Rev 2 Page 15 © 2012 Snell Limited...
  • Page 16: Fiber-Inputs 1-4 Screen

    Reclock Bypass: Check this to bypass the reclocker, which is on the output signal. • The Channel Ident, I/P Name, receiver SFP Status (relating to product SPF fit), I/P State, I/P Rate, Rx Power (value and alarm status) are shown for each channel. Issue 1 Rev 2 Page 16 © 2012 Snell Limited...
  • Page 17 Config 1, the Secondary must be routed in Config 2. Also, to prevent the configuration switching backwards and forwards between configurations, it must also be routed in Config 1. Issue 1 Rev 2 Page 17 © 2012 Snell Limited...
  • Page 18: Output-Fiber Screen

    The Output-Fiber screen shows status associated with the fiber transmitters. Fiber Optic Tx 1-4 Shows the fiber transmitter status for each channel. SFP Status relates to the product SPF fit. Issue 1 Rev 2 Page 18 © 2012 Snell Limited...
  • Page 19: System-Memory 1-16 Screen

    To recall a memory: • In the Recall Memory column, select the memory to recall. The recalled set-tings will be applied and the memory name will appear in the Last Recalled Memory section. Issue 1 Rev 2 Page 19 © 2012 Snell Limited...
  • Page 20: Logging

    Logged parameters are made available to logging devices connected to the RollCall Network. They are also displayed on a number of RollCall Screens where they can selectively be switched off to prevent them being logged externally. Issue 1 Rev 2 Page 20 © 2012 Snell Limited...
  • Page 21 IQOTR40/41/42/43/44/45/99 www.snellgroup.com Issue 1 Rev 2 Page 21 © 2012 Snell Limited...
  • Page 22 IQOTR40/41/42/43/44/45/99 www.snellgroup.com Issue 1 Rev 2 Page 22 © 2012 Snell Limited...
  • Page 23 IQOTR40/41/42/43/44/45/99 www.snellgroup.com Issue 1 Rev 2 Page 23 © 2012 Snell Limited...
  • Page 24 SDI inputs are designated SDI Input 1-4 and the Fiber inputs are designated Fiber Input 1-4 , in the logging, the SDI input channels are logged as channels 1-4 and the fiber receiver channels are logged as channels 5-8. Issue 1 Rev 2 Page 24 © 2012 Snell Limited...
  • Page 25: Rollcall Log Fields

    <SFP fit status for Fiber I/P 1> <blank> No SFP Required (TR99) ERR:Tx ERR:No Rx ERR:Extra Rx (TR99) WARN:Elec Rx ERR:UNKNOWN … … INPUT_8_SFP <SFP fit status for Fiber I/P 4> Issue 1 Rev 2 Page 25 © 2012 Snell Limited...
  • Page 26 WARN:HI FAIL:HI <blank> (SFP fit error) … … INPUT_8_RX_POWER_STATE <Rx SFP 4 power alarm/warning state> INPUT_5_RX_POWER <Rx SFP 1 power> -4.1dBm … … … INPUT_8_RX_POWER <Rx SFP 4 power> -4.1dBm Issue 1 Rev 2 Page 26 © 2012 Snell Limited...
  • Page 27: System-Rolltrack Screen

    Using RollTracks To enable or disable RollTrack functions: • To disable RollTrack functions, select the Disable All check box. • To enable the RollTrack functions, clear the Disable All check box. Issue 1 Rev 2 Page 27 © 2012 Snell Limited...
  • Page 28 Bad: RollTrack message has not been sent correctly, acknowledged at the destination unit. This could be because the destination unit is not of the type specified. • Disabled: RollTrack sending is disabled. Issue 1 Rev 2 Page 28 © 2012 Snell Limited...

This manual is also suitable for:

Iqotr41Iqotr42Iqotr43Iqotr44Iqotr45Iqotr99

Table of Contents