Room&Board 776074 Adara Collection Owner's Manual

Rectangle fire table

Advertisement

Available languages

Available languages

Quick Links

776074 Adara Collection
1112NG-TGR Rectangle Fire Table Owner's Manual
WARNING
!
For outdoor use only.
DANGER
!
If you smell gas:
• Shut off gas to the appliance.
• Extinguish any open flame.
• If odor continues, keep
away from the appliance and
immediately call your gas
supplier or fire department.
WARNING
!
Do not store or use gasoline or other flammable liquids
in the vicinity of this or any other appliance.
An LP-cylinder not connected for use should not be
stored in the vicinity of this or any other appliance.
WARNING
!
Improper installation, adjustment, alteration, service, or
maintenance can cause injury or property damage.
Read the installation, operation and maintenance instructions
thoroughly before installing or servicing this equipment.
170919FTNG-171130
DESIGNED AND BUILT BY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 776074 Adara Collection and is the answer not in the manual?

Questions and answers

Summary of Contents for Room&Board 776074 Adara Collection

  • Page 1 DESIGNED AND BUILT BY 776074 Adara Collection 1112NG-TGR Rectangle Fire Table Owner’s Manual WARNING WARNING Do not store or use gasoline or other flammable liquids For outdoor use only. in the vicinity of this or any other appliance. An LP-cylinder not connected for use should not be DANGER stored in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information Parts List Assembly Instructions Pre-Use Instructions Lighting Instructions Care and Cleaning Spider and Insect Warning Tips & Troubleshooting Technical Parts List Warranty DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Installation notes • Minimum Clearance from unit to combustible materials: 48” (121.9 cm) from all sides and back. Do not place this fire table under any overhead structure or vegetation. Do not place on or above combustible surfaces. •...
  • Page 4 IMPORTANT SAFETY INFORMATION General Warnings (Cont.) • Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
  • Page 5: Parts List

    PARTS LIST ITEM R&B Number JCo NUMBER QUANTITY Fire Table Body 11122005 NG Hose and 056NG010 Quick Connect Socket Black Lava Rock 970274 100240120J Protective Cover 869214 11120002 Valve Key 711797 11110004...
  • Page 7: Assembly Instructions

    ASSEMBLY INSTRUCTIONS 3.) Connecting your fire table to the natural gas source: A professionally installed shut-off valve between the supply piping and the socket is recomended by the National Fuel Gas Code, and must be used for this fire table. A professional gas technicial or plumber must make sure that your house’s gas system is capable of providing the correct amount of gas at the correct pressure for your ire table to operate safely and correctly.
  • Page 8 ASSEMBLY INSTRUCTIONS 4.) Connecting the Socket Coat the gas supply pipe nipple with gas approved pipe compound or tape. Screw the quick connect socket included with your fire table onto the gas supply pipe. The quick disconnect should not be permanently attached to the gas hose on the fire table.
  • Page 9: Pre-Use Instructions

    PRE-USE INSTRUCTIONS WARNING Before using this fire table, make sure you have read, understand, and are following all information provided in this manual. Failure to follow these instructions could cause property damage, serious injury or death. Checking for Leaks Make a leak check solution by mixing one part dish-washing soap with three parts water in a spray bottle.
  • Page 10: Lighting Instructions

    LIGHTING INSTRUCTIONS Lighting the Fire Table 1. Read and understand all operating instructions before lighting. 2. Before beginning, make sure the key valve is in the OFF position. 3. Connect the fire table to the gas supply and make sure the gas is on (see previous pages). 4.
  • Page 11: Care And Cleaning

    CARE AND CLEANING Inspecting Your Fire Table WARNING DO NOT inspect, clean, move or store your fire table until the flames are COMPLETELY out and all parts are cool to the touch. Your fire table should be inspected regularly to ensure that it is safe to use and to extend the life of its parts.
  • Page 12: Spider And Insect Warning

    SPIDER AND INSECT WARNING Spiders or other insects may build webs or nests in your fire table burner which can obstruct or block the flow of gas. Some of the gas may back up in the burn tube and cause a flashback (a fire in the burn tube or underneath the fire table) which could result in personal injury or property damage.
  • Page 13: Tips & Troubleshooting

    TIPS & TROUBLESHOOTING If the fire table will not ignite or stay lit Make sure that the gas shut-off valve is fully open and that the connection between the hose and the quick connect socket is correct. Verify that the valve key is not stripped out and that the valve is opening/ closing.
  • Page 14: Technical Parts List

    TECHNICAL PARTS LIST Burner Kit 11110004 Rectangle Lid 11122005 NG Hose and Quick Connect 056NG010 Thumb Screw 11110006 Foot x 4 115010003 Lava Rock 100240120J Protective Cover 11120002...
  • Page 15: Warranty

    WARRANTY & RETURN POLICIES Warranty Real Flame® Company warrants the body and internal components of this Real Flame gas fireplace to be free from defects under normal use with a limited 2 year warranty from the date of purchase. The burn tube and nozzels carry a lifetime warranty. In the event of defects Real Flame will, at its option, replace the defective product or refund the purchase price.
  • Page 16 DISEÑADO Y CONSTRUIDO 776074 Adara Collection Manual del propietario del fogón rectangulo 1112NG-TGR ADVERTENCIA ADVERTENCIA No almacene ni use gasolina u otros líquidos inflamables Para uso sólo en exteriores. en las cercanías de este o de cualquier otro artefacto. PELIGRO Un cilindro de LP no conectado para el uso no debe ser almacenado cerca de este o de cualquier otro artefacto.
  • Page 17 ÍNDICE Información importante de seguridad Lista de partes Instrucciones de montaje Instrucciones de pre-uso Instrucciones de iluminación Cuidado y limpieza Advertencias relativas a insectos y arañas Consejos y solución de problemas Lista técnica de partes Garantía PELIGRO PELIGRO DE MONÓXIDO DE CARBONO Este artefacto puede producir monóxido de carbono que no tiene olor.
  • Page 18 INFORMACIÓN IMPORTANTE DE SEGURIDAD Notas de instalación • Distancia mínima de la unidad a los materiales combustibles: 48” (121,9 cm) de todos lados y parte trasera. No coloque el fogón debajo de ninguna estructura o vegetación. No lo coloque sobre ningún material combustible. •...
  • Page 19 INFORMACIÓN IMPORTANTE DE SEGURIDAD Advertencias generales (Cont.) • No use este artefacto si alguna de sus partes estuvo debajo del agua. Llame inmediatamente a un técnico de servicio calificado para inspeccionar el fogón y substituir cualquier parte o sistema de control y cualquier control de gas que haya estado debajo del agua.
  • Page 20 LISTA DE PIEZAS PRODUCTO NUMÉRO R&B NUMÉRO JCo CANTIDAD Cuerpo del fogón Tapa 11122005 Manguera de GN y 056NG010 conector de conexión Roca de lava negra 970274 100240120J Cobertura de protección 869214 11120002 Llave de válvula 711797 11110004...
  • Page 21 INSTRUCCIONES DE MONTAJE 1.) Coloque la roca de lava u otro material de relleno de Real Flame a mano en la zona de quemado. No vacíe la bolsa en el área del quemador, ni directamente sobre el quemador para evitar que el quemador se obstruya con polvo. Coloque el material de relleno a lo largo de la zona de encendido hasta alcanzar un nivel de una pulgada y media (1/2”) por encima del quemador.
  • Page 22 INSTRUCCIONES DE MONTAJE 3.) Conexión del fogón a la fuente de gas natural: El Código Nacional de Gas Combustible recomienda una válvula de cierre instalada profesionalmente entre la tubería de suministro y la conexión y debe ser utilizada para este fogón. Un técnico de gas profesional o fontanero debe asegurarse de que el sistema de gas de su casa es capaz de proporcionar la cantidad correcta de gas a la presión correcta para el fogón para poder operarlo con seguridad y correctamente.
  • Page 23 INSTRUCCIONES DE MONTAJE 4.) Realizar la conexión Cubra la boquilla del tubo de suministro de gas con un compuesto de tubería aprobado para gas o cinta adhesiva. Atornille el conector de desconexión rápida incluido con el fogón en el tubo de suministro de gas. La desconexión rápida no debe fijarse permanentemente a la manguera de gas en el fogón.
  • Page 24 INSTRUCCIONES ANTES DEL USO ADVERTENCIA Antes de usar el fogón, asegúrese de haber leído, comprendido y seguido toda la información proporcionada en este manual. El incumplimiento de estas instrucciones puede ocasionar daños a la propiedad, lesiones graves o la muerte. Verificar fugas Prepare una solución para el control de fugas mezclando 1 parte de detergente/jabón lavavajillas con 3 partes de agua en una envase pulverizador.
  • Page 25 INSTRUCCIONES DE ENCENDIDO Encendiendo la Mesa de Fuego Lea y comprenda todas las instrucciones de funcionamiento antes de encender. 2. Antes de comenzar, asegúrese de que la válvula de la llave esté en la posición CERRADO. 3. Conecte el fogón al suministro de gas y asegúrese de que el gas esté encendido (consulte las páginas anteriores).
  • Page 26 CUIDADO Y LIMPIEZA Inspeccionar el fogón ADVERTENCIA NO inspeccione, limpie, mueva o almacene el fogón hasta que las llamas estén TOTALMENTE apagadas y todas las partes estén frías al tacto. Este fogón debe ser inspeccionado regularmente para asegurar que el producto es seguro y para extender la vida del mismo y sus partes.
  • Page 27 ADVERTENCIA DE ARAÑAS DE INSECTOS Las arañas y otros insectos pueden construir telas o nidos en el fogón, que pueden obstruir o bloquear el flujo del gas. Parte del gas puede retroceder hacia el tubo de combustión y provocar un llamarada de retroceso (fuego en el tubo de combustión o debajo del fogón) lo que podría producir lesiones personales o daños a la propiedad.
  • Page 28 CONSEJOS Y SOLUCIÓN DE PROBLEMAS Si el fogón no se enciende o no permanece encendido Asegúrese de que la válvula de cierre de gas está completamente abierta y que la conexión entre la manguera y el conector de desconexión rápida es correcta. Verifique que la llave de la válvula no esté...
  • Page 29 LISTA TÉCNICA DE PARTES Juego de quemadores Llave 11110004 Tuerca de Tapa acople 11122005 1111-20 Manguera de GN y conector de desconexión 056NG010 Tornillo mariposa 11110006 Pies x 4 115010003 Roca de lava 100240120J Cobertura de protecció 11120002...
  • Page 30 POLÍTICAS DE GARANTÍA Y DEVOLUCIÓN Garantía Real Flame® Company garantiza el cuerpo y los componentes internosde esta chimnea de gas están libres de defectos en sus partes en condiciones de uso y servicio normales por un período de 2 años a partir de la fecha de compra.

This manual is also suitable for:

1112ng-tgr

Table of Contents