Installation Instructions
ELEKTROMAT SE 9.32-25,40
RP09/32RD
Model: 10002729 10012
-en-
Status: 25.11.2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELEKTROMAT SE 9.32-25,40 and is the answer not in the manual?

Questions and answers

Summary of Contents for GFA ELEKTROMAT SE 9.32-25,40

  • Page 1 Installation Instructions ELEKTROMAT SE 9.32-25,40 RP09/32RD Model: 10002729 10012 -en- Status: 25.11.2019...
  • Page 2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales@gfa-elektromaten.co.uk www.gfa-elektromaten.co.uk...
  • Page 3: Table Of Contents

    Table of contents General safety information ....................4     Technical Data ........................ 5     Mechanical installation ....................6     Electrical installation ..................... 10     Limit switch adjustment ....................11     Motor connection ......................12    ...
  • Page 4: General Safety Information

    1 General safety information Specified normal use The drive unit is intended for sectional doors with full counter-balancing. The safe operation is only guaranteed with normal specified use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions. No liability for damage caused by other applications or non-observance of the information in the manual.
  • Page 5: Technical Data

    2 Technical Data Type SG 50 Output torque Output speed Output shaft / hollow shaft 25,40 Maximum output speed open / close 55 / 32 for frequency inverter operation Maximum holding torque Maximum door weight 4000 Supply voltage 3~ 400 Operating current 1,20 Operating frequency...
  • Page 6: Mechanical Installation

    3 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data). Connection elements: ▶ Self-locking connection ▶ Utilize the hole diameter ▶...
  • Page 7 Mounting Eight threads are provided for mounting. ▶ Use at least 2 of these (①). Keys are used to connect to the door shaft. ▶ Use a key that is at least as long as the hollow shaft (②). BAGAD0 1 0 0 1 _Z0 0 2 8 x (M8x16)
  • Page 8 Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life!  During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
  • Page 9 ▶ Attach the drive unit. BAGAE0 1 0 0 3 _Z0 0 3 ▶ Tighten all connection elements (M8) to 25 BAGAE0 1 0 0 6 _Z0 0 2 Nm. Install all other connection elements according to the specifications of the door manufacturer.
  • Page 10: Electrical Installation

    4 Electrical installation Warning - Danger to life from electric current!  Switch the mains OFF and check that the cables are de-energised  Observe the applicable regulations and standards  Make a proper electrical connection  Use suitable tools Performing electrical installation Remove the cover.
  • Page 11: Limit Switch Adjustment

    5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel.
  • Page 12: Motor Connection

    6 Motor connection Motor X13 Motor plug 7 Alternative motor connection Motor X13 Motor plug...
  • Page 13: Limit Switch Connection

    8 Limit switch connection Thermal contact S10 Manual operation X12 DES connection Safety circuit Channel B (RS485) Ground Channel A (RS485) Safety circuit Supply network...
  • Page 14: Emergency Manual Operation (Rapid Hand Chain Operator)

    9 Emergency manual operation (rapid hand chain operator) Emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible. Warning – Injuries due to incorrect operation! ...
  • Page 15 Switch on by pulling the red handle. Open or close by pulling the chain. Switch off by pulling the green handle.
  • Page 16: Completing Commissioning / Inspection

    10 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion. Mounting Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are secure and in proper condition.
  • Page 17: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...