A Operator level – overview
Setting level
Domestic hot water mode (product with integrated hot water generation or connected
domestic hot water cylinder with temperature sensor)
Water temperature
Heating mode
Heating flow temperat-
ure
B Status codes – Overview
Note
Since the code table is used for various products, some codes may not be vis-
ible for the product in question.
Codes that are not listed here can be found in the installation instructions.
Status code
S.00
Heating mode: No requirement
S.02
Heating mode: Pump pre-run
S.03
Heating mode: Burner ignition
S.04
Heating mode: Burner on
S.06
Heating mode: Fan overrun
S.07
Heating mode: Pump overrun
S.08
Heating mode: Temporary shutdown after heating procedure
S.10
Hot water handling mode: Requirement
S.14
DHW mode: Burner on
Display in Comfort mode with warm start or hot water handling mode with cylinder
S.20
Hot water handling mode: Requirement
S.22
Hot water handling mode: Pump pre-run
S.24
DHW mode: Burner on
S.31
No heating demand: Summer mode, eBUS controller, waiting period
S.34
Frost protection active
0020258017_00 ecoTEC pure Operating instructions
Values
Increment, select, explanation
Min.
Max.
Current value < 35 = OFF
35 ℃
60 ℃
Current value < 10 = OFF
Underfloor heating = 35-50
Radiator = 35-80
Note
10 ℃
80 ℃
The temperature range above 75 °C
can only be set by a competent per-
son.
Displays in heating mode
Displays in hot water handling mode
Other displays
Meaning
Appendix
Default set-
ting
OFF
OFF
17