Command-Line Interface
Run the System Setup Wizard
Log in with the following credentials:
Step 2
Username: admin
•
Password: ironport
•
Access the command-line interface locally or remotely:
Step 1
To access the CLI locally, set up a terminal to connect to the serial
•
port using 9600 bits, 8 bits, no parity, 1 stop bit (9600, 8, N, 1) and
flow control set to Hardware. To physically connect the terminal,
see the
"Connect to the Appliance" section on page
To access the CLI remotely, initiate an SSH session to the IP address
•
192.168.42.42.
Log in as admin with the password ironport.
Step 2
At the prompt, run the systemsetup command.
Step 3
The System Setup Wizard starts automatically when you access the appliance via
the web-based interface (or when you run the systemsetup command from the
command-line interface.)
Start the System Setup Wizard.
Step 1
Accept the end user license agreement.
Step 2
Enter information from the
Step 3
page
3.
Set anti-spam and anti-virus security settings.
Step 4
Review the configuration summary page.
Step 5
Click Install this Configuration.
Step 6
"Document Network Settings" section on
7).