Optical Adjustments; Contrast Adjustment - Sanyo PLC-XE50A Service Manual

Hide thumbs Also See for PLC-XE50A:
Table of Contents

Advertisement

■ Optical Adjustments

Before taking optical adjustments below, remove the Cabinet Top following to the "Mechanical Disassembly".
Adjustments require a .0mm hex wrench and a slot screwdriver. When you adjust Integrator lens or Relay lens adjustment,
you need to disconnect FPC cables of LCD panels on the main board.
Optical adjustment requires a .0mm hex wrench and a slot screwdriver.
Note: Do not disconnect connectors on the main board, because the projector cannot turn on due to operate the power
failure protection.
WARNING : USE UV RAdIAtIoN EYE ANd SKIN PRotEC-
tIoN dURING SERVICING
CAUtIoN: to prevent suffer of UV radiation, those adjustment must be com-
pleted within 25 minutes.

Contrast adjustment

[Before Adjustment]
- Input a 100% of black raster signal.
1
A (Fig.1)
Loosen a screw
you intend to adjust.
2
B
Adjust the slot
to obtain the darkest brightness on the screen by using
a slot screwdriver.
3
A
Tighten the screw
to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
on the polarized glass mounting base which
Slot B
Polarized glass
mounting base
- 35 -
A
Fig.1

Advertisement

Table of Contents
loading

Table of Contents