Operation - Outdoor Leisure PGLHB36 Owner's Manual

Hide thumbs Also See for PGLHB36:
Table of Contents

Advertisement

Available languages

Available languages

CAUTION: Do not stand in
front of heater while lighting.
Stand at the side when lighting
the heater.
Use only a 20 lb. propane/LP cylinder (not
included). See safety information for proper
cylinder selection. Connect the hose/regula-
tor assembly to the cylinder (see Figure 3).
The hose should already be connected to the
heater. Connect hose to the valve inlet (see
Figure 3). Tighten firmly using a wrench.
Valve
Inlet
Hose/Regulator
Assembly
20 lb.
Propane/LP
Cylinder
Figure 3 - Connecting Hose/Regulator
Assembly to Propane/LP Cylinder
Chain
Retainer
Figure 4 - Attaching Lightpost/Burner
Assembly to Cabinet Assembly
123221-01A

OPERATION

Route retention chain through at least one
of the handles of the propane/LP tank (see
Figure 3). Make sure to route chain through
handle on tank and NOT around tank valve.
Chain must not interfere with valve. Attach
hooks on both ends of chains to chain retain-
ers installed on cabinet base (see Figure 4).
CHECKING FOR LEAKS
1. Turn heater valve to OFF position.
2. Turn cylinder supply valve fully counter
3. Use a noncorrosive leak detection solution
Retention
Chain
LIGHTING INSTRUCTIONS
Gas Light
1. Press power switch to ON, gas light will
2. Press power switch to OFF to turn gas
3. To turn off gas supply to gas light, turn
Note: Be sure manual shutoff valve is in the
ON position to operate gas light.
Control
Valve
Main Burner
1. Push heater control knob in and turn coun-
Control
Valve Nut
2. Push control knob in and press ignitor
and Control
Knob
3. Continue holding knob in for approxi-
Cabinet
Assembly
4. For more heat, press knob and rotate
5. If RELIGHTING, wait 5 minutes for heater
Ignitor
ON/OFF
Switch
G A S L I G H T
P O W E R S W I T C H
Figure 5 - Gas Light Heater Controls
www.desatech.com
clockwise to OPEN position.
to check the connection for leaks before
attempting to light heater. If leak is found,
turn cylinder valve to CLOSE and do not
use until all leaks are corrected.
automatically light.
light off.
knob on manual shutoff valve to OFF.
Manual shutoff valve is located on gas
train assembly inside of heater cabinet.
ter clockwise to the START position.
button. Repeat until heater is lit.
mately 30 seconds. Heater should remain
lit in the LOW heat setting.
counterclockwise to HIGH setting.
to cool and gas to clear, then follow steps
1 through 3.
ON
OFF
I G N I T O R
OFF
START-LOW
H I G H
5